| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND RESONABLE | |
| 2 | L2₹95.0 L+₹3.0 L (3.30%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹97.8 L+₹5.9 L (6.41%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹98.2 L+₹6.3 L (6.85%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹1.0 Cr+₹8.2 L (8.94%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
7 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KOLKATA
Headquarters commander Works Engineers Military Engineer Services No 1, National Library Avenue Alipore, Kolkata 700 027
PROVN OF GEYSER WITH CONNECTION IN JCO / OR MD ACCN AT KOLKATA MIL STN
2022_MES_545002_1
8202/E-15/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(C) AND GE(FW) KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
GE(C) KOLKATA
₹2.1 L
30 Sept 2022
12 Aug 2022
12 Sept 2022
12 Aug 2022
7 Sept 2022
31 Aug 2022
12 Aug 2022 - 22 Aug 2022
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. (ii) It is highlighted that the cretin condition of General Condition Of Contracts (IAFW-2249) has been modified as direction of MOD i.e inclusion of performance security, deletion of risk & cost provisions and increase in defects liability period all as specified in tender document. The tenderers should keep in mind while quoting their offer
Excavating in trenches, not exceeding 1.5 metres wide and not exceeding 1.5 metres depth for foundation etc and getting out in soft / loose soil complete all as specified and directed
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft / loose soil complete all as specified and directed
Removing excavated material to a distance n.exc 50m and deposited where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium stranded conductor cable 1100 volt grade 120 Sqmm 3.5 core laid in duct / floor / wall with provision of saddle and lugs, joints etc including connection complete all as specified and as directed.
Supply, Jointing and testing of outdoor termination heat shrinkable type jointing kit complete with jointing materials and accessories suitable for 1100 volts grade 120 Sqmm 3.5 core XLPE insulated armoured aluminium conductor cable complete all as specified and directed .
Supply, Jointing and testing of indoor termination heat shrinkable type jointing kit complete with jointing materials and accessories suitable for 1100 volts grade 120 Sqmm 3.5 core XLPE insulated armoured aluminium conductor cable complete all as specified and directed .
Material and labour for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
Cutting / boreing of existing road / path, hardstandings etc for taking out cable and water pipe to protection with iron cover plate for passing cable, water pipe and making good the disturbed road top surfaces with following cement, concrete all type using of suitable depoth and finished with speed breaker complete all as specified and directed.
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation, base of poles and other similar locations including demolition of old PCC / broken PCC complete all as specified & directed.
Material and Labour for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping / collar of poles and foundation including necessary formwork etc complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cemet complete all as specified and directed.
Supply and fixing 16 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors with necessary clips complete all as specified and directed by Engr-in-Charge .
Supply and fixing 15mm dia fancy type CP Anguler stop cock / Stop Valve, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & directed.
Supply and fixing PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Supply and fixing 15mm dia Bib taps, CP with crutch or butterfly handle, screwed down, screwed for iorn pipe or for brass ferrule and fixed complete all as specified and directed.
Supply and fixing vertical electric water heater, storage type, shock resistant ABS body, stainless steel inner tank with triple shield technology, glass line coating with high density PUF insulation, copper heating element upto 2 KW, 230 volts, capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, 4 nos fixing bolt of suitable size including nuts and washer etc and making the electrical connection including testing after installation complete all as specified and directed. Make:- Crompton (Model No : Versa) , Havells (Model No:PURO EX), Racold (Model No : CDR), Bajaj (Model No: Montage) Note : Contractor Shall submit manufacturer test report as per BIS to GE before payment.
Supply & fixing switch socket combination , 3 pin,16A ,230 Volt, box type complete all as specified and directed.
Material and labour for point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor cables of 4.0 sqmm size, 1100 volts grade alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 4.0 sqmm size,1100 volt drawn through and including PVC casing and caping of suitable size with accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting one switch socket combination of 16 AMps on independent board, Complete all as specified and directed.
Supply and fixing MCB SP of rating 6 to 32 Amps 240 V capacity 10 KA ISI marked complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, GI strip protected by 40mm bore light grade GI pipe and other connected to earth test point as directed including funnel with watering pipe 20mm bore light grade galvanised iron, wire mesh, charcoal or coke commom salt laid in alternative layer of 15cm (complete thickness) all round the eaarth electrode, concrete earth pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC(1:2:4) type B1normal mix cover slab reinforced with 8mm dia TMT bar 10 cm c/c bothways and single handle of 10mm dia round bar including necessary excavation,earth work etc in soft / loose soil and disposal of soil to a distance n.exc 50m and necessary tasting on completion all as shown in electrical plate No 3 MES Schedule Part-I complete all as specified and directed.
Supply, instalation, testing and commissioning feeder pillar box CPRI type tested of size 1.5 mtr x 1.2 mtr x 0.60 mtr outdoor type conforming to IP-54, factory made double door both front and back side, with locking arrangement prewired made out of 3.15mm thick MS sheet with 04 Nos legs, MS angle iron 40 x 40 x 6mm size 0.9 mtr long suitable grouted in ground with PCC 1:3:6 type C2 and cement plaster 1:4 including two coats or synthetic enamelled paint over a coat of red oxide primer both internally & externally including provision of cable entry and exit at mid portion of the feeder pillar box (with cable gland), and providing one number Danger Notice Plate (of size 15 cm x 10 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour, fixed with clamps and nuts-bolts of suitable size) and providing necessary foundation of the feeder pillar box in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) and all the accessories to be connected with suitable copper conductor (Control wiring) and power connection with busbar, connection of cable with necessary lugs, glands, PVC tape complete all as specified and directed . (a) Auminium bus bar 600 Amps(size 40mm x 10mm x 400mm) capacity including insulator with nuts & bolt - 4 Numbers (b) LCD Multifunctional digital meter with CT for measuring voltage ampere, frequency, KW, KWH - 1 no (c) LED type indicator lamps with holder (RYB) - 01 Set (d) MCCB 400 Amps, 4 Pole , 36 KA, fixed thermal and magnetic relase type - 01 Nos (incomming) (e) MCCB 100 Amps, 4 Pole, 25 KA,fixed thermal and magnetic relase type - 03 Nos (Outgoing) (f) MCB FP 32 Amps- 02 Nos
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .