Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.2 LAccepted-Finance | ₹9.2 L | 1 | Accepted-Finance Admitted |
| 2 | 2₹10.5 LAccepted-Finance | ₹10.5 L | 2 | Accepted-Finance Admitted |
| 3 | 3₹10.9 LAccepted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | ₹10.9 L | 3 | Accepted-Finance Admitted |
| 4 | Rejected-Technical | - | - | Rejected-Technical FDR not submitted |
| 5 | Rejected-Technical NITIN ENGINEERING INDIA SANDEEP YADAV CONTRACTOR ISHWAR CONTRACTOR SHREE SALASAR ASSOCIATES | - | - | Rejected-Technical FDR not submitted |
| Sl No | Description | Qty | Unit | M/s S.G. Enterprises L2 | Raj Engineering Co. L1 | MITTAL TRADING COMPANY L3 |
|---|---|---|---|---|---|---|
| 1.01 | Supply of Horizontal Split Casing Pump with CI Impeller, SS Shaft & SS Sleeve Suction 125 mm and Delivery 100 mm having Discharge capacity 144M3/Hr. at 40 Mtr. Head with complete MS base frame of Pump set made of M.S. channel size 100 x 50mm and M.S. sheet as per site requirement and Coupling and Coupling guard for 40 HP pump set as per site requirement. Make: Kirloskar / M&P/ Jyoti/ Lubi/ DJB Approved | 2 | Nos. | 5,10,000 ₹6,01,800 | 4,98,000 ₹5,87,640 | 2,00,000 ₹2,36,000 |
| 1.02 | Supply of 100 mm dia. NRV, Make: Kirloskar / IVC/DJB Approved | 2 | Nos. | 31,200 ₹36,816 | 24,800 ₹29,264 | 20,000 ₹23,600 |
| 1.03 | Supply of 100 mm dia sluice valve (delivery side) Make: Kirloskar / IVC/DJB Approved | 2 | Nos. | 29,156 ₹34,404.08 | 24,800 ₹29,264 | 26,000 ₹30,680 |
| 1.04 | Supply of 150 mm dia sluice valve (suction side) Make: Kirloskar / IVC/DJB Approved | 2 | Nos. | 37,800 ₹44,604 | 45,000 ₹53,100 | 36,000 ₹42,480 |
| 1.05 | Supply of 100 mm dia. Flange 12 mm thick | 5 | Nos. | 3,000 ₹3,540 | 2,300 ₹2,714 | 5,000 ₹5,900 |
| 1.06 | Supply of 150 mm dia. Flange 12 mm thick | 5 | Nos. | 3,000 ₹3,540 | 2,550 ₹3,009 | 7,500 ₹8,850 |
| 1.07 | Dismantling of old motor pump sets from foundation by disconnecting electric connection from main power supply, cutting foundation bolts, removing of coupling, damaged sluice Valves, damaged NRV, damaged Taper Pieces on Suction & Delivery side both with the help of gas cutter, specialized labour and manual chain pulley block etc. as per site requirement. | 2 | Jobs | 35,800 ₹42,244 | 15,000 ₹17,700 | 30,000 ₹35,400 |
| 1.08 | Closing of suction and delivery line by providing with M.S. blank flange of size 150 mm & 100 mm including rubber sheet and M.S nuts and bolts as per site requirement and direction of engineer-in-charge. | 2 | Jobs | 10,000 ₹11,800 | 5,000 ₹5,900 | 40,000 ₹47,200 |
| 1.09 | Dismantling of damaged M.S. base frame after cutting of damaged jammed foundation bolts with gas cutter from existing RCC platform with the help of all the mechanical/manual means as per site requirement. Breaking of RCC foundation with pneumatic concrete breaker for taking out the damaged foundation bolts and mild steel bars& taking out the malba from the pump house and dispose/stack at a suitable place as directed by engineer-in-charge. | 2 | Jobs | 30,934 ₹36,502.12 | 15,000 ₹17,700 | 80,000 ₹94,400 |
| 1.10 | Making of complete new RCC foundation for pump set. The job includes casting of new RCC foundation, providing of M.S. Jall made of 16 mm bars at bottom & center of RCC foundation. Fixing of new foundation bolts by tightening /Welding of foundation bolts with M.S Jall & filling of R.C.C material in the complete foundation including welding, shuttering and plastering as per requirement. | 2 | Jobs | 25,800 ₹30,444 | 27,000 ₹31,860 | 1,60,000 ₹1,88,800 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
30 Jan 2026, 3:30 pmClosed
EE(EnM)M-12
D-Block Saket
Renovation - Replacement of Existing Pump for Better Water Supply at Chungi No.2 Lal Kaun BPS under Tughlakabad Constituency AC-52.
2026_DJB_285349_23
NIT No. 29/EE(EnM)M-12/2025-26
Open Tender
Miscellaneous Works
30 days
EE(EnM)M-12
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
EE(EnM)WnSS-II
₹24,000
5 Mar 2026
22 Jan 2026
30 Jan 2026
22 Jan 2026
30 Jan 2026
22 Jan 2026
Supply of Horizontal Split Casing Pump with CI Impeller, SS Shaft & SS Sleeve Suction 125 mm and Delivery 100 mm having Discharge capacity 144M3/Hr. at 40 Mtr. Head with complete MS base frame of Pump set made of M.S. channel size 100 x 50mm and M.S. sheet as per site requirement and Coupling and Coupling guard for 40 HP pump set as per site requirement. Make: Kirloskar / M&P/ Jyoti/ Lubi/ DJB Approved
Supply of 100 mm dia. NRV, Make: Kirloskar / IVC/DJB Approved
Supply of 100 mm dia sluice valve (delivery side) Make: Kirloskar / IVC/DJB Approved
Supply of 150 mm dia sluice valve (suction side) Make: Kirloskar / IVC/DJB Approved
Supply of 100 mm dia. Flange 12 mm thick
Supply of 150 mm dia. Flange 12 mm thick
Dismantling of old motor pump sets from foundation by disconnecting electric connection from main power supply, cutting foundation bolts, removing of coupling, damaged sluice Valves, damaged NRV, damaged Taper Pieces on Suction & Delivery side both with the help of gas cutter, specialized labour and manual chain pulley block etc. as per site requirement.
Closing of suction and delivery line by providing with M.S. blank flange of size 150 mm & 100 mm including rubber sheet and M.S nuts and bolts as per site requirement and direction of engineer-in-charge.
Dismantling of damaged M.S. base frame after cutting of damaged jammed foundation bolts with gas cutter from existing RCC platform with the help of all the mechanical/manual means as per site requirement. Breaking of RCC foundation with pneumatic concrete breaker for taking out the damaged foundation bolts and mild steel bars& taking out the malba from the pump house and dispose/stack at a suitable place as directed by engineer-in-charge.
Making of complete new RCC foundation for pump set. The job includes casting of new RCC foundation, providing of M.S. Jall made of 16 mm bars at bottom & center of RCC foundation. Fixing of new foundation bolts by tightening /Welding of foundation bolts with M.S Jall & filling of R.C.C material in the complete foundation including welding, shuttering and plastering as per requirement.
Providing of MS Gap Piece of size 100 mm thickness medium class duly welded with both side MS Flangeas per site requirement.
Providing of foundation bolts with nuts and washer of size 16 mm dia and 450 mm long.
Providing of MS Taper of Size: 150 mm X 125 mm thickness 8 mm approx.: 45 cm. Heavy class duly welded with both side MS Flange as per site requirement
Providing of Tyre Type automatic Flexible Cushion Coupling TC/J/015 DJB SOR 2022
Making of bore & cutting of Key-way in coupling as per the shaft size of pump & motor i/c providing & fixing of key of both sides of coupling.
Fabrication & fixing of Coupling Guard made out of 50 mm X 6 mm M.S flat, 50 mm X 6 mm M.S angle & 14 SWG M.S sheet duly primer & painted.
Providing of MS nut bolts with washer as per site requirement.
Providing of Rubber insulation sheet.
Fixing of MS base frame of New Pump Sets on the RCC Foundations & tightening with foundation Nut Bolts, fixing of Electric motor Pump set on the MS Base Frame with proper alignment and tightening the same with the help of tools & tackles, heavy manual labour etc. as per site requirement and direction of engineer-in-charge.
Making of all Electrical Connection by using Aluminum armoured cable with required items i.e. thimble, ferrule etc. as per site requirement and direction of engineer-in-charge.
Making suction connection by fixing of sluice valve, gap piece & flange as per site requirement making delivery connection by fixing of sluice valve, NRV, Taper piece & flange with the help of tools and tackles, heavy manual labour as per site requirement and direction of engineer-in-charge.
Arrangement of all safety equipment for the protection of manpower to work smoothly and to make the working area free from accident during working at site as per NHRC guidelines.
Painting the complete as above-mentioned structures with the help of all accessories including supply of paint and primer & painting with 1 coat of primer and 2 coats of enamel paint as per site requirement and direction of engineer in charge.
Testing and commissioning of complete system at no load and full load with all the required tests.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_377563.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid