Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.4 L+₹18,444.50 (0.96%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹20.9 L+₹1.7 L (8.79%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
3 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
GE Alwar
REPAIR/CLEANING OF SEWAGE SYSTEM IN MD AND OTM ACCN UNDER AGE B/R-I AT ITARANA, ALWAR
2022_MES_561566_1
8112/E8
Open Tender
Civil Works
Item Rate
210 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹60,000
Yes
7 Jan 2023
4 Nov 2022
5 Dec 2022
4 Nov 2022
3 Dec 2022
19 Nov 2022
4 Nov 2022 - 18 Nov 2022
Amount
Cleaning of Sewage line of 100mm bore from gully traps, grease traps etc. upto 1.5m deep by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley, all as specified & directed.
All as per description of serial item No 1.00 here-in-before but sewage line of 150mm bore and depth of sewage line upto 1.5m.
All as per description of serial item No 1.00 here-in-before but sewage line of 150mm bore and depth of sewage line exc1.5m and n exc 3m
All as per description of serial item No 1.00 here-in-before but sewage line of 200mm to 250mm bore and depth of sewage line exc 1.5m and n exc 3m.
All as per description of serial item No 1.00 here-in-before but sewage line of 200mm to 250mm bore and depth of sewage line exc 3m and n exc 4.5m.
Cleaning of septic tank of any capacity or description including cleaning and pumping out fluid, cleaning of sludge from compartment of septic tank including intercepting chamber & washing down with water complete and removing the sludge in covered van/trolley out side the MD land, complete all as directed.
Cleaning of manholes depth upto 1.5 mtr by removing all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils out side MD land and taken out cover slab and reset in the same position after cleaning and testing all as specified and directed. cleaning shall be done either manually or mechanically as required and directed by Engr-in-charge.
All as per description of serial item No 7.00 here-in-before but depth exceeding 1.5m and not exc 3m deep complete all as specified & directed.
All as per description of serial item No 7.00 here-in-before but depth exceeding 3m and not exc 4.5m deep complete all as specified & directed.
Cleaning of all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100 mm/75 mm dia CI pipe stacks upto 1st Manhole, CI/SGSW pipe between gully trap & 1st Manhole, CI Tee/Door bends etc to maintain internal sewage system in the area of AGE B/R - II (Itarana) with and including manual/pressure cleaning pump & flexible rods and other necessary equipments complete all as specified and directed by Engr-in-Charge. Note : (i) Contractor or his authorised representative collect such type of complaints from B/R-I complaint cell at 8.30 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint. (ii) Complaint must be completed within 24 hours without any fail otherwise recovery shall be made double the market rate to the contractor.
Dismantling of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.
All as per serial item No 12.00 here-in-before but except bricks. Note : Old serviceable bricks retrieved from serial Item No 11.00 here-in-before shall be re-used under this item.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:4 complete all as specified & as directed.
All as per serial item No 14.00 here-in-before but except stones. Note : Old serviceable stones retrieved from serial item No. 11.00 here-in-before shall be re-used under this item.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
Demolition of reinforcement cement Concrete of any description and in any position (reinforcement cut as required to facilitte demolition) all as specified and as directed.
M&L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete.
M&L PCC 1:2:4 type B1 using 20mm graded stone aggragate as in bed blocks, bed plates, coping etc including weathering slightly rounded or chamfered angles and throating making groves for fixing of man hole cover including necessary form work.
M&L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately.
M&L cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.
M&L reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L rendering 15mm thick in cement mortar 1:4 on brick/stone masonry surfaces or surfaces of brick/Stone work of walls, finishing the surface even & smooth without using extra cement complete all as specified.
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation or for shafts, walls, manholes etc not exc. 10 Sqm on plan and getting out in soft/loose soil.
All as per serial item No 26.00 here-in-before but depth exc 1.5m and not exc 3m.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
Demolition and breaking up 150 mm bore drain pipes, salt glazed stone ware set in cement mortar including PCC haunching and bedding, complete.
Demolition and breaking up 200 mm bore drain pipes, salt glazed stone ware set in cement mortar including PCC haunching and bedding, complete.
S&F salt glazed stone ware drain pipes of 150mm bore, grade `A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified.
M&L 150 mm bore reinforced concrete pipe, class NP2, laid and jointed (in CM 1:1) complete with collars all as specified & as directed
M&L 200 mm bore reinforced concrete pipe, class NP2, laid and jointed (in CM 1:1) complete with collars all as specified & as directed
M&L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in bedding to SGSW/NP2 drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and as directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in bedding to SGSW/NP2 pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 200 mm bore pipe all as specified and as directed.
M&L cutting into existing manholes / septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B1 smooth finished and reforming benching as required for 150mm bore pipe.
All as per serial item No 37.00 here-in-before but for 200 mm bore pipe.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in trenches or in floors complete all as specified including dismantling of PCC & taking out old unserviceable 110mm bore PVC pipe with fittings & making good disturbed area complete all as specified & directed.
S&F 50mm thick steel fibre reinforced (SFRC) man hole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton/Sqm in square, rectangular or circular shape complete all as specified & as directed.
S&F in repairs salt glazed stone ware gully trap square or round mouthed type 'P' of size 150mm x 150mm with CI grating, setting & jointing with cement with grouting surrounding gully trap with PCC 1:3:6, type C1 block 30x30x45cm together with necessary form work, excavation & earth work in soft/loose soil, complete all as specified and as directed.
M&L cement concrete 75mm thick 1:2:4 type B-2 using 40mm graded stone aggregate as in pathways/ hardstanding laid in alternate ways, each panel not exceeding 3.00 Sqm finished the surface even and fair without using extra cement and joint to be filled with Bituminous mastic filling including necessary form work complete all as specified & directed.
shiva construction
J.J.ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .