Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical B 2 SHRI GAJANAN CHS L T DILIP GUPTE RD MAHIM WEST MUMBAI MAHARASHTRA 400016 | MUMBAI | MAHARASHTRA | 400016 | Accepted-Technical Technically Qualified |
| 2 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 3 | Accepted-Technical 4B 27 TILAK NAGAR NEW DELHI DELHI 110018 UDYAM DL 11 0062400 | WEST DELHI | DELHI | 110018 | Accepted-Technical Technically Qualified |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
29 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director Sports
Punjab yuwa bhawan sector 42 a chandigarh
Purchase of Biomechanical equipments
2025_DOS_153616_1
07 DATED 12.11.2025
Open Tender
Medical Equipments/Waste
Item Wise
Hockey stadium mohali
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
₹2.5 L
Yes
Punjab yuwa bhawan sector 42 a chandigarh
22 Jun 2026
14 Nov 2025
29 Dec 2025
14 Nov 2025
29 Dec 2025
14 Nov 2025
26 Nov 2025
It should be Portable and should have 2 Load cell sensors per unit with easy to attach hooks pivoting 360 Degrees joint improving sensor accuracy • It should have knee position indicator for replication of test position in each time. • Should have Sample rate per sensor: upto 400HZ, Capacity per sensor: 100 kg/980-1000N Safe • Over load per sensor: 150Kg/1500N, max Over load per sensor: 200Kg/ 2000N, Resolution: 1N and Sensitivity: 22.0+/-mV/V. • Should have Rechargeable battery & battery life should be100 Active hours approx. • Should have Working temperature Range 5-40®C. (All weather proof) • Latest upgradable software should have both wired & wireless connectivity • Connectivity through USB (Wired) • Bluetooth Low Energy (BLE) for iPad & iPhone i.e. (Wireless Connectivity) • Should provide 4 Years Warranty on Hardware, should be provided with latest upgradable software and free software updates. • Should have software available in Mobile & Laptop (Desktop) application with Cloud analytics Platform Applications. • Should have ability to collect data both Local i.e. laptop and on iOS devices. • Local Software:- For Data collection & data Analysis Locally. • Cloud Software:- for Athlete Data Management and analysis. • Local (Desktop /Laptop) Software should be Compatible with Windows 10 Desktop Application iOS 13 or later Application (iPad & iPhone). • should have ability to collect data of over 10000 Athletes or more to choose with simple name search / Grouping them. • Cloud Analytics Platform for analysis. • Software (Application) must give real time feedback of testing. • License must be valid for 4years. • Cloud Software: - Should automatically sync all data collected on local mobile and laptop application when connected to internet. o Should have a Dashboard to see overview of organization’s Athletes data and different tiles (Data indicators) to see Athletes within and outside threshold zones. • Report Section:- should have port section to able to compare different groups/athletes on Longitudinal data. • Should have ability to compare same athlete’s data over the period. • Athletes Profile:- Should have functionality to enter Anthropometry (i.e. Upper Body & Lower Body measurement). • Athletes profile should be auto sync to Local Application and flexibility to move across different Groups or Teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). • Should be able to setup different access to different people i.e. to Physiotherapist, Sports Scientist and S&C trainer within the organization to secure data access. API Integration:- should have Open-source API Code for integration into Athlete Management System to integrate in AMS System. • Should have software License valid for 4years. • Wi-Fi Tablet 64GB, Space Grey-1Year Warranty (as provided by OEM) - Service by Customer Service of OEM only.HSN:8471. Training for installation and demonstration shall be provided at Olympian Balbir Singh senior International Hockey Stadium, Sector- 63, Mohali, Punjab.
The system should be supplied with minimum 16 high speed Wireless EMG Channel with built in IMU sensor. • Should Have Analog+ Digital base station • Should have analogy output option to facilitate integration with third party hardware and software • Sensor should have fixed inter sensor delay of 0.5 milliseconds or less Sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk • Sensor contacts should be made up of a metal for better contact and better-quality signal • Should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength • Sensors, Sensor skin interface, cable, power adapter and accessories • Sensors facilitate EMG and IMU measurements • EMG data analysis software for stand-alone usage with live recording of at least 32 channels and analysis for both online and offline modes. • Trigger module package • Analog adapter with cable for dynamometer integration. • Should have option for real time data streaming to computational software’s such as mat lab. • Mobile EMG suite for outdoor applications • Technical support for the lifetime or at least for a period of 05 years. The system should be supplied with sensor docking unit and charging system • The system should be supplied with double sided adhesive stickers (at least 5000) and double-sided adhesive tape rolls (at least 20). • The system should be supplied with at least 2000 Hz of sampling rate or more per sensor. • The system should have a baseline noise < 1 µV or better. • The EMG System should have +20,000 µ VEMG input range or better. • The system should have Software controlled digital filtering, the system should have shielded cables for minimal artifact. • The software should allow video recording during EMG data recording • Should have at least 8 hours of battery backup • Should have wireless working range of at least 40m or more to capture data during various sport specific movements, should be configurable to 32 channels in future. • The EMG system should be integrated with 3D motion analysis, Force plate, Isokinetic dynamometer, Instrumented treadmill, IMU, eye tracking, video analysis etc. • The necessary third-party hardware/ software should be supplied by the seller for integration of EMG with other systems. • Laptop i7 (latest generation) with 32GB ram or more, 2TB SSD, at least 15.6-inch screen and Laser Printer with copy/scan/print to generate and view report and additionally a 32-inch Monitor for dual display. • USFDA, ISO & EUIEC certificates or equivalent. Installation at the Institute and training to the users by experts Training for installation and demonstration shall be provided at Olympian Balbir Singh senior International Hockey Stadium, Sector- 63, Mohali, Punjab.
It should be a wireless speed gate with 12 gates and provision for increasing gates up to 15 gates/splits or more with “split distance” fully customizable to perform variety of testing (can have splits at 1 meter or 10 meters or customized distance). • It should be Photocell & reflector system only (light or laser based) considering flexibility it offers to use variety of testing protocols with visual cue (light system provide a cue to the athlete to change direction) i.e. single or dual feedback functions for athletes. • It should have an accuracy of minimum 1 hundredth of a second (1/1000th of a second) or beyond, with a system to eliminate errors caused by hands, feet and other body parts, equipment (to provide most accurate data) Must have Error Correction Processing (ECP) inside the timing unit. • Wireless Range: - Should be able to control gates wirelessly with a range up to 180-200 meters. • It should have functionalities to provide 6 Options when using different accessories a. Auto Beam Break b. In-Beam c. Reactive d. Start Pad e. Vibration (Reaction Time measures) f. RFID Various accessories should be integrated with Timing gates thus providing various testing possibilities of athletes. • It should integrate with a Jump Mat (accessories) for plyometric training and explosive power measurement with multiple jump testing option on Jump Mats. • Tests & Drills to be measured System must be able to measure- i. Linear (straight line sprints), shuttles with customized split distance. ii. Yoyo, Beep Tests (with custom customized time interval for endura
Kinematic Analysis System (Open)
analysis: Rear-foot eversion/inversion, lateral pelvic drop, Trunk side bending, crossover gait, knee flexion, leg inclination angle, knee toe-alignment, hip extension, ankle plantar flexion, net vertical oscillation of center of mass, knee ab /adduction, Ground contact time etc.. Data to be measured for both left and right extremities. (c) Posture Analysis: Major postural deviations like rear-foot eversion /inversion, forward head posture, shoulder protraction, genu recurvate, lateral head tilt, shoulder level, lateral pelvic drop, lateral trunk sway, Q angle (d) Sitting posture Angle: Viewing angle, Viewing distance, forward head angle, Elbow flexion/extension, Trunk flexion/extension, Knee flexion/extension, Hip knee alignment (e) Bike fitting: Major parameters like Ankle plantar flexion /dorsiflexion, knee flexion/ extension, Hip flexion, Hip vertical travel, back angle, elbow angle, armpit angle, KOPS, knee tracking. (f) Squat Analysis: Major parameters like Descent: Ascent ratio, Squat stance width, heel rise detection, head tilt, shoulder tilt, Lateral trunk tilt, pelvic tilt, frontal knee alignment, knee-toe alignment, trunk inclination (sagittal plane), tibia inclination (sagittal plane), knee flexion (depth of squat). 6. It should be able to generate organized reports with following features: (a) Data represented in tabular & photographic form (b) In built reference ranges for every parameter measured. (c) All data lying outside reference ranges to be highlighted in bold (d) Automatic documentation of all observations and abnormal biomechanics in form of notes (with choice of Hindi or English language if needed). (e) Automatic Summary of all reports should be generated. 7. It should have an option to export all data to excel sheets 8. It should have an inbuilt comparison feature that generates post comparison reports to monitor changes in patient’s posture and gait. 9. It should have an in-built data base feature for storing analysis data. 10. Software should use AI (Artificial intelligence) models to provide markerless analysis. 11. Software should also use AI (Artificial intelligence) models to aid in marker digitization in case of marker based analysis. 12. Motion Capture cameras supporting video capture in outdoor conditions (running track) as well as indoor conditions (floor, walkway & treadmill). Camera specifications: (a) Wired Cameras–04 in numbers with capture rate up to 60 fps. (b) WirelessCameras-02 in numbers with capture rate up to 240 fps. 12. The system should have data transfer cables and connector cables for camera along with Tripods for mounting of cameras. 13. Marker Set (with marker placement guide) for Standing posture, walking gait analysis, running gait analysis and Bike Fitting with reusable markers or disposable markers (adequate in number for conducting at least 100 tests each) 14. Compression Clothing for lower body & upper body should be provided. 15. Quality Clearance for cameras: USFCC/ EUCE/ ISOBIS (either of the certifications). 16. Should be safe and non-invasive, easy to use. 17. Carry case/bag for storing and carrying all hardware equipment to be provided. 18. In person training, virtual assistance & Technical support for System operation. 19. The biomechanical analysis software should have license validity along with all updates and bug fixes for a minimum period of 10 years. 20. The system should come with a hardware warranty of 3 years. 21. Computer specifications: Intel 5th generation processor or better, 8 GB RAM, windows 10/11, at least 2 USB ports.
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_311332.xls
BOQ • 0.32 MB
sbd.pdf
Tender Documents • 1.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .