Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 CrAccepted-AOC | ₹23.1 Cr Quoted ₹23.8 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹27.9 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹27.9 Cr | L2 | Rejected-Finance Not lowest |
| 3 | L3₹34.0 CrRejected-Finance | ₹34.0 Cr | L3 | Rejected-Finance Not lowest |
| 4 | L4₹35.5 CrRejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹35.5 Cr | L4 | Rejected-Finance Not lowest |
Tender Value
₹23.2 Cr
EMD Value
₹14.8 L
Closing Date
2 Mar 2024, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar, Lekhawada Patia, Chiloda 382042
DEMOLITION AND RECONSTRUCTION OF MD ACCN FOR AIRMEN AT SION AREA AT AF STN MUMBAI (PHASE-II)
2024_MES_638124_1
84199
Open Tender
Civil Works
548 days
GE (AF) Thane
All as per Tender Documents
7 documents required · 7 mandatory
₹3,000
GE (AF) Thane
₹14.8 L
Yes
10 Apr 2024
18 Jan 2024
4 Mar 2024
18 Jan 2024
2 Mar 2024
17 Feb 2024
22 Jan 2024 - 29 Jan 2024
Amount
NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 1.00 to 14.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS / STRUCTURES as listed in Sch 'A’ Part I.
Lump sum price worked out for DEMOLITION as listed in Sch 'A’ Part II.
Lump sum price worked out for EXCAVATION, EARTH WORK & SITE CLEARANCE as listed in Sch 'A’ Part III.
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A’ Part IV.
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A’ Part V.
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A’ Part VI.
Lump sum price worked out for AREA DRAINAGE / RAIN WATER HARVESTING as listed in Sch 'A’ Part VII.
Lump sum price worked out for ROAD/ PATH/ HARDSTANDING as listed in Sch 'A’ Part VIII.
Lump sum price worked out for WALL/ FENCING/ GATE as listed in Sch 'A’ Part IX.
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A’ Part X.
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part XI.
Lump sum price worked out for HOT WATER SUPPLY as listed in Sch 'A’ Part XII.
Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch 'A’ Part XIII.
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A’ Part XIV.
SCHEDULE `A' PART-XV MISCELLANEOUS ITEMS OF WORK (Note: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
DEMOLITION
Taking down carefully ceiling fan, geyser exhaust fan and electric meter from ceiling, wall complete and depositing to MES store yard for safe custody complete all as specified and directed.
Taking down sub main wiring of any size complete all as specified and directed.
Taking down unserviceable DB/ TPN (including MCCB/ MCB), main switch of any capacity complete all as specified and directed.
Taking down old unserviceable LT XLPE cable of any size complete all as specified and directed.
Taking down RCC LT pole including bracket, protection pipe, light fitting, GI clamps and looping box complete all as specified and directed.
Taking up or down GI/CI pipe of any size including all fittings and fixtures complete all as specified and directed.
Taking down LT feeder box, bus bar, MCCB, MCB complete from foundation complete all as specified and directed.
Taking down valve, valve pit chamber of any size complete all as specified and directed.
Disconnection of all electric connections and dismantling of pumping set with motor starter panel/automation panel of any capacity, fresh water to 'P' and A-F block pump 7.5 HP-02 Nos and depositing to MES store yard for safe custody complete all as specified and directed. Note:- General note to be included in UG Sump.
Taking down earthing strip, down conductor, earthing rod etc. complete all as specified and directed.
INTERNAL WATER SUPPLY
Supply, laying, fixing and testing galvanised steel water tubing, ISI marked, medium grade galvanized with and including all tube fittings ISI marked and fixtures such as tees, elbows, diminishing pieces etc. complete fixed to wall and ceiling or laid in floors for 65 mm bore pipe complete all as specified and directed.
Supply and fix stop valve/ angle valve 15 mm bore of pipe, minimum finished mass 0.575 kg each (ISI marked), fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for (externally threaded) for iron pipe or for union complete all as specified and directed. Note: Flow rate should not be more then 2.5 LPM as per GRIHA norms
Supply and fix bib taps for 15 mm bore of pipe, minimum finished mass 0.575 kg each (ISI marked), fancy type, chromium plated with long shank and cup, cast copper alloy screwed down, high pressure with crutch or butterfly handle complete all as specified and directed. Note: Flow rate should not be more then 2.5 LPM as per GRIHA norms
Supply and fix two way bib cock 15 mm dia ISI marked, fancy type, chromium plated complete all as specified and directed. Note: Flow rate should not be more then 2.5 LPM as per GRIHA norms
Supply and fix pillar taps, cast copper alloy with capstan head chromium plated, fancy type, with or without lettered HOT or COLD with long screwed for iron pipe and fixed to 15 mm bore pipe, complete all as specified and directed. Note: Flow rate should not be more then 2.5 LPM as per GRIHA norms
Supply and fix brass chromium plated shower rose with swivel joints, including fixing to steel pipe or union complete all as specified and directed. Note: Flow rate should not be more then 6 LPM as per GRIHA norms
Supply and fix forged brass pressure reducing valve screwed in bonnet spring loaded capable of handling maximum inlet pressure of 3.0 kg/cm2 and capable to deliver outlet pressure 0.5 to 1.5 kg/cm2 for diameter of pipe 80 mm bore complete all as specified and directed.
Supply and fix forged brass pressure reducing valve screwed in bonnet spring loaded capable of handling maximum inlet pressure of 3.0 kg/cm2 and capable to deliver outlet pressure 0.5 to 1.5 kg/cm2 for diameter of pipe 65 mm bore complete all as specified and directed.
Supply and fix forged brass pressure reducing valve screwed in bonnet spring loaded capable of handling maximum inlet pressure of 3.0 kg/cm2 and capable to deliver outlet pressure 0.5 to 1.5 kg/cm2 for diameter of pipe 50 mm bore complete all as specified and directed.
Supply and fix forged brass pressure reducing valve screwed in bonnet spring loaded capable of handling maximum inlet pressure of 3.0 kg/cm2 and capable to deliver outlet pressure 0.5 to 1.5 kg/cm2 for diameter of pipe 40 mm bore complete all as specified and directed.
Supply and fix forged brass pressure reducing valve screwed in bonnet spring loaded capable of handling maximum inlet pressure of 3.0 kg/cm2 and capable to deliver outlet pressure 0.5 to 1.5 kg/cm2 for diameter of pipe 25 mm bore complete all as specified and directed.
INTERNAL ELECTRIFICATION
Supply and fix cable tray perforated aluminium pre-galvanised 200x75x25mm, passing through vertical wall, chiseling, cutting on vertical/ horizontal wall including make good of disturbed surface complete all as directed.
Supply, install, testing and commissioning of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) indoor type, platform mounted, including suitable angle iron (4 Nos leg) for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2.00 mm CRCA sheet 75mm x 30 mm thick MS channel frame, duly powder coated finish, thimbling and cable entry boxes with cable gland including painting with two coat of synthetic enamel paint over a coat of red oxide primer, front and back side opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal and suitable PCC work complete all as specified and directed. The scope of work includes provision of the following:- Incoming:- (a) MCCB 4 pole 100 Amps, 36 KA, 415V - 01 No (b) Bus bar (copper strip) 200 Amp - 4 Nos (c) Digital panel meter (Amp Voltage meter) including CTs - 01 No (d) Digital indication lamp set - 01 Set (e) Slot for electronic energy meter - 14 Nos Outgoing:- (i) MCB TPN 63 Amp 415 V 50 Hz-14 Nos Note:- Contractor shall submit LT panel drawing for approval of GE before procurement.
Supply and fix anti suicide rod for hanging of ceiling fan all as specified and as directed.
AREA DRAINAGE/ RAIN WATER HARVESTING
Material and labour for 150 mm bore PVC slotted pipes single socketed, in any length with rubber ring joints, laid in bore hole for recharge pit or fixed to wall complete all as specified and directed.
Material and labour for boring holes of 300 mm dia in soil/ ground for recharge pits and getting out and removing/ disposal of soil to a distance exceeding 250 metre but not exceeding 500 metre complete all as specified and directed.
ROAD/PATH/HARDSTANDING
Material and labour for Polythene film, black 400 micron laid in floors etc. complete all as specified and as directed.
Material and labour for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘A’ with 20 mm dia mild steel dowel bars 50cm long (25cm in each slab) with ferrules, spaced at 300 mm centres, including boring form work and preformed filler for dowels etc. complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Supply and laying ductile iron pressure pipes, centrifugally cast [spun], class "K-7" of 100mm size with socket and spigot ends conforming to IS - 8329 in standard lengths suitable for push-on rubber gasket jointing with inside cement mortar lining and black bitumen external coating including taking down any description and any size of pipe complete all as specified and as directed. Note: Excavation, earth work and DI special shall be measured and paid separately.
Supply and fix foot valve confirming to IS 4038, 80mm dia to suction line with all necessary fittings complete all as specified and directed.
Material and labour for construction of valve chamber of internal size 900 x 900 x 900 mm, including necessary earthwork in any type of strata, PCC 1:3:6 in base concrete brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS sheet cover with hinges and locking arrangement fixed to angle iron frame made out of 50 x 50 x 5 mm size complete with two coats of synthetic enamel paint over a coat of red oxide onn all steel work and two coats of white washing on plastered surfaces of valve chamber complete all as specified and directed.
Supply, fix and installation of pumping sets, centrifugal, electric driven, 10 HP, 60 mtr 12 LPS head inclusive of starter, priming arrangement for pumps with water tanks and PCC foundation (fresh water) with all necessary fittings complete all as specified and directed.
Supply and fix water disinfection system comprising of the following complete all as specified and directed: (a) Chlorine dosing pump: high pressure single head gear motored adjustable dosing pump with accessories including lead tubing, connecting nuts, injection check valve, clay weight and ferrules - 01 No. (b) Altoc dosing system consisting of 40 Litre PE/ FRP tank with PE/ FRP lid and level gauge along with agitator with shaft and blade in plastic, mounted on tank.
EXTERNAL ELECTRIC SUPPLY
Supply and install, testing and commissioning of transformer as per IS: 1180 Part-I, level-III step down, copper wound 11KV/433 Volts (at no load) AC 3 Phase 50HZ 250KVA capacity, core type, oil immersed naturally air cooled, oil natural, air natural (ON/AN), with external cooling tubes, delta connected on primary side (AV) and star connected on secondary side (LV) in accorance with vector ground DYn-11 with neutral brought out on secondry siede (LV) and having taping at+5% to 10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changegear. The max temp rise should not exceed 50 degree celsius in oil and 55degree celsius in HV/LV winding when measured by resistance method after continuous full load run on and ambient temp of 40 degree celsius. Transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeablity prime grade cargo with M4 grade or better, perfectly insulated and clamped to min noise and vibrations. The transformer shall be IS/IEC 60076 and as per IS-1180 Part-I of 2014 marked and shall comprise of the following:- (a) One cable box on HT side (Primary side consisting of three nos porcelain bushing with copper rods, complete with nuts and washer, with cable glands suitable for reception/taking out 3core 120sqmm, HT 1100 volts grade XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out single core 100sqmm, LT 1100 volts, grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete.
(c) Conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, Oil level guage, Oil drain filter valve, lifting ligs, oil filling hole with cap/plug with connection plate complete, air release valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having max perimeter temp reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal making plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested upto 50KV dielectric strength at 2.5mm air gap between testing electrodes, specific resistance at 27 Degree celsius Ohm-om 500x10 the power 12, water content 50PPM, Dielectric dissipation factor (tan Deta at 90degree celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03 Inter facial tension N/M at 27 degree celsius-.0.04, flash point 140 degree celsius and sluge 0.1% by weight. (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Transformer losses shall not exceed the losses mentioned in Table 6 of IS: 1180 of 2014 Part-I. (n) Oil temperature indicator.
Supply, install, commissioning and testing, outdoor type micro processor based, APFC panel, MD-XL capacitor and MCCB as incomer made of 3.15 mm thick CRCA sheet, front and back openable doors, having key arrangemnet, of capacit 125 KVAR, having 5 stage auto corrector stage in conbination of (2x12.5 KVAR+2x25 KVAR+1x50KVAR) capacitor, ISI marked with suitable incoming and outgoing MCCBs, contactors with protections, voltmeter, ammeter, indication lamps etc. complete and all as specified and directed. Note:- GA drawings of the same is to be submitted to GE prior to procurement.
Suppyling, installing, testing and commissioning in of LT panel (outdoor type) board not less than 120cmx120cmx65cm made out of 3.5mm thick CRCA sheet duly powder coated, completely weather, vermin and dust proof, CPRI approved with colour code PVC sleeves for bus bar, front opened, with locking arrangements, closed bus bar chamber, angle iron frame of size 50x5x6mm for skeleton and support embedded in concrete foundation comprising of the following (Main Panel).
Suppyling, installing, testing and commissioning of outdoor type LT panel (indoor type) board not less than 120cmx120cmx65cm made out of 3.5mm thick CRCA sheet vermin proof, including painting with synthetic enammeled paint CRPI aproved with colour code PVC sleeves for bus bar, front opend with locking arrangmement, closed bus bar chamber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following (water supply & fire fighting panel):-
Suppyling, installing,commissioning in of indoor type LT panel (indoor type) board not less than 120cmx120cmx65cm made out of 2.0mm thick CRCA sheet vermin proof, including painting with synthetic enammeled paint CRPI aproved with colour code PVC sleeves for bus bar, front opend with locking arrangmement, closed bus bar chamber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprisiion of the following (Bldg panel):-
INCOMING (a) MCCB, 415 Volts, 400 Amps rating, 4 pole, microprocessor based, service breaking capacity 50KA - 01 No. (b) Digital voltmeter 0-500 volts- 01 (c) Digital ampere meter 0-300 Amps with and including CTs - 01 OUTGOING (a) MCCB 63 Amp rating 4 pole, 25KA 415 Volts 50Hz- 14 Nos Each floor TPN DB) (b) MCCB, 40 Amp rating 4 pole, 25KA 415 Volts, 50Hz- 02 Nos (Spare). (c) MCB SPN 32 Amp, rating 2 pole- 01 Nos (Bldg security light). (d) Internal wiring of panel wit stranded copper cable of suitable size. (e) Neon phase indicating lamp (set of three)- 01 Set (f) Stenceiling of panel board including making of distributions.
Suppyling, installing,commissioning in of indoor type LT panel (outdoor type) board not less than 120cmx120cmx65cm made out of 3.5mm thick CRCA sheet vermin proof, including painting with synthetic enammeled paint CRPI aproved with colour code PVC sleeves for bus bar, front opend with locking arrangmement, closed bus bar chamber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprisiion of the following (Stand by panel):-
Material and labour for maintenance free chemical gel based earthing, using GI pipe having 75mm dia 3 mtr long with 25kg back fill compound all as required at site including testing on completion and taking down of old earthing all as directed by Engineer-in-charge including FRP cover of suitable size. Note:- Earth resistance of earth pit should be less tha 3.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing shall be redone at no extra cost.
Material and labour for loop out junction box and suitable connection for three phase incoming cable three phase out going cable and single phase connection of light fitting with controlled MCB SP-6Amps-01 No. enclosed in thermo plastic in closed shock proof safe complete all as specified and directed.
Spply and fix GI steel tubing brackets made up of light grade 40mm dia 1.5 meter length and bent to shape at factory of offset angle upto 120 degree for fixing of LED street light fittings including preparing the surface of steel tubing and applying two coats of aluminium paint complete all as specified and as directed.
Supply, laying and testing PVC insulated, PVC sheathed cable galvanished steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm 2 core, 1100 volts grade complete all as specified and as directed.
LIFTS
Suppy, installation, testing, commissioning, putting into operation and final testing of automatic electric operated lift of 8 passengers capacity (544 kg) with a speed of 1.5 mtr/sec, to serve up to (G+13) = 14 floors, with single speed motor 415 Volts, 3 phase, AC 50 Hz, supply confirming to IS 14665, with AC variable voltage & variable frequency drive (VVVF drive), Automatic rescue device (ARD) system, 2D infrared sensor in full height of door & built in announcing system with hand set (04 Nos, one each in car, machine room and near ground floor landing) complete with all standard equipments, accessories and control equipments as per manufacturer design, conforming to NBC/ local by laws and fulfilling the following requirements complete all as specified and directed: (MRS TYPE)
(i) Type: Passenger lift (ii) Load: As specified elsewhere from 2 passenger to 13 Passenger for 13 Passenger lift and 2 passenger to 8 passenger for 8 passenger lift (For each person standard weight of 68 Kg) (iii) Speed: 1.5 metre/sec (iv) Motor/ Machine: AC variable voltage & variable frequency drive (VVVF drive), Electric motor driven mechanism (v) Operation: simplex automatic and manual dual controlled operation with/without attendant (vi) Total rise: 14 stops only (vii) Landing: All floors on the same side (viii) Floor Served:G+14 (ix) Signals: Digital car position indicator, car travel direction indicator inside car and at all landings, voice annuciator with suitable music shall be provide in the lift car (x) Shaft size: As per manufacturer's design specification, shaft to be constructed separately (xi) Guide rail: As per manufacturer's specification (xii) Lift and car size: As per manufacturer's specification (xiii) Car entrance: As per manufacturer's specification (xiv) Car door: Centre opening doors with door drive, sliding stainless steel doors (xv) Landing door: centre opening doors with door drive, sliding stainless steel doors (xvi) Car ceiling and lighting: S.S (Stainless steel) finish with aesthetic appearance with LED ceiling lights
(xvii) Car Ventilation: Pressure fan/ blower fan (Car fan with automatic sleep timer shall be provided) (xviii) Emergency lighting in car: Battery operated emergency lighting in the lift car (xix) Intercom system: Battery operated Intercom system in lift car,machine room and ground floor/ control room (xx) Emergency alarm: Battery operated alarm bell system in lift car and control room/ ground floor (xxi) All car panel buttons and all floor switches must be with brail language as per lift act. (xxii) Audio visual indication in the lift car showing overloading shall be provided such that doors are kept open till excess load removed. (xxiii) Spring buffer/hydraulic buffers shall be provided. (xxiv) Mechanical over speed governor, door key holes in the floor doors shall be provided. (xxv) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxvi) In the hoist way fascia plate shall be provided. (xxvii) Permanent writing in the lift machine room and lift well with proper no. of light point, with fixtures, exhaust fan, plug point and 3 phase 440V power supply shall be made available by the department in the lift shaft, machine room or at desired level (xxviii) Car top safety barricade shall be provided
(xxix) ARD (Automatic Rescue Device): Solid state inbuilt automatic rescue device (ARD) for automatic rescue of passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure Note for item No. 58:- Lift of 8 passenger capacity is to be used as passenger lift and as firemen lift to be effective in fire fighting operation. The firemen lift shall have the following requirements. (i) The firemen's lift may be used by the occupants in normal times. (ii) The firemen's lift shall be provided with a firemen switch. The switch shall be a two position (ON/OFF) switch fixed at the evacuation floor (Normally main entrance floor) for enabling the lift to be put into firemen's mode. The switch shall be situated in a glass fronted box with suitable level and fixed adjacent to the lift at the entrance level. When the switch is on, landing call points shall become inoperative and the lift shall be on car control only or on a priority control device. When the switch is off, the lift will return to normal working.
(iii) The firemen's lift shall be provided with an audio and visual signal in car. (iv) The firemen's lift shall have a floor area of minimum 1.43 sqm. It shall have loading capacity of not less than 544kg (8 person lift). (v) The firemen's lift shall be provided with power operated (automatic) doors of minimum 0.8 mtr width. (vi) The speed of firemen's lift shall be 1 m/s or more such that it can reach the top floor from main floor/ firefighter access level within 1 minute incase of building zoned, the firemen's lift shall operate from the lowest served landing to the top most served landing in 1 min. (vii) The words "Firemen lift" shall be conspicuously displayed in fluorecent paint on the lift landing (viii) All other operation requirements of firemen's lift.
All as per item No. 58 above but lift of 13 passengers capacity (884 kg)
DG SET
Supply, installation, testing and commissioning of Diesel Engine driven Generating Set of capacity 100 KVA with AMF panel including emission control device as per latest Govt policy wih water cooled engine of suitable BHP for 80 KW power generation @ RPM 1500, brushless frame with silencer and canopy for soundless mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/ dynamo and 80 KW/ 100 kVA electric alternator, 415 Volts, 3 Phase, 4 WIre, 50 Hz, Voltage regulation +/- 1, insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components, fuel tank capacity as per OEM recommendations with level indicator installed on suitable steel frame with PCC foundation as per manufacturer instructions, Power command genset controller, fuel pipes, dual spin on fuel filter, Dritype aircleaner, shutoff coil with safeties for LLOP/HWT, bar meter, hour meter, oil temperature gauges, ammeter, ignition switch, radiator with cooling fan, maintenance free battery, including suitable size of copper cable leads with terminals, all mountings, accesories and necessary foundation and AVM pads complete as per manufacturer recommendations and to the complete satisfaction of Engnr-in-charge.
(A) Prime Mover: Suitable for driving 80 kW/ 100 kVA alternator liquid cooled battery start diesel engine of adequate capacity 159 BHP confirming to ISO 8528-5G2 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hour in any 12 hrs operation complete with the following standard accesories:- (a) Fly wheel to match with the flexible coupling (b) Flexible coupling with guard (c) Air cleaner oil bath type/ dry type (d) Lubricating oil filter, fuel filter paper element type (e) Blower type fan and radiator (f) Governor for class 'A' governing as per IS-1601 of DS 649/1958 (g) Starter motor for electric start complete with dynamo alternator, lead acid batteries heavy duty of capacity 12 V 65 Ah or as per OEM recommendations, Nos. and capacity as required with copper conductor leads of adequate size and length not less than 2 M including battery box all as specified
(h) Hour meter and RPM indicator (j) Exhaust pipe brought outside the building and lagging of entire length of exhaust pipe 12 mm dia. (k) Instrument panel duly wired comprising the following including protection for low lub oils high temperature:- (l) Lube oil pressure gauge (m) Battery change indicator meter (n) Starting switch with key (o) Lub oil temeperature (p) Engine temperature indicator (B) Alternator:- 80 kW/ 100 kVA at 0.8 PF brushless self excited, self regulated 3 phase 50 Hz 415 V 1500 RPM 4 wire screen protected drip proof free from simulation problems continuous rating confirming to IS/ IEC 60034-1 complete with automatic voltage regulator O/P voltage regulated between +/- 1 % or set voltage from no load to full load
(C) Automatic Mains Failure Panel:- AMF panel for 80 kW/ 100 kVA DG set fabricated out of sheet steel factory made suitable for floor mounting hinged from panel for easy accessibility with suitable rated bus bar internal wiring and with provision for connecting incoming/ outgoing leads with the following accesories:- (a) HRC fuse (06 Nos) of proper rating for both incoming and MCCB 200 Amps 4 Pole - (03 Nos) for incoming (b) Auxillary contactors 200 Amps, 415 Volt, 3 Phase, 4 Pole with timer (on delay) - 02 Nos (c) Multi functional meter - 01 No. (d) KWH meter electronic digital type - 01 No. (e) Two set of indicator lamps 6 Nos LED type for main and DG indication (f) Master switch for auto/ manual/ test/ off (g) One set of lamps for indicating "load on set", " load on mains", "set fails to start", "low oil pressure", "high cylinder tamp", "battery low" (h) Alarm/ hooter (j) Battery charger connected to main supply side to charge battery comprising the following:- (k) Indicator lamp for battery (l) Set for easily accesible control fuses (m) Set for relays to auto-start the engine on main failure and low voltage (n) Emergency trip
AVIATION OBSTRUCTION LIGHT
Supply and fix aviation obstruction LED light 18 Watts with control box of sheet metal enclosure including MCB SP 10 Amps 10 KA 230 Volts AC with timet, contactor complete all as specified and directed by Engineer-in-charge.
FIRE FIGHTING
Supply and fixing strainer Y type confirming to IS, size 250mm (10") dia complete all as specified and as directed.
Supply and fix 200 mm dia double flanged flexicon expansion joint (expansion bellows) of standard length as per manufacturer's specifications including rubber gaskets, flanges, nuts, bolts and washers etc. complete as per standard specification and as directed.
Supply and fix 65 mm dia double flanged flexicon expansion joint (expansion bellows) of standard length as per manufacturer's specifications including rubber gaskets, flanges, nuts, bolts and washers etc. complete as per standard specification and as directed.
Supply and erection of autostart panel (24V) for the diesel engine complete with auto/manual switch, indication lamps protective fuses with battery charger, suitable of working on 230v AC, single phase enclosures being vermin and dust proof, also potential free conducts shall be provided for connecting to the building automation system, Battery shall be 2x12V, 180AH. Two sets of battery bank controlled by a suitable change over swiich, DC control on/off switch, Battery charger on/off switch, Hooter, Push button, terminal block, supply of 100mm cable tray, supply of panel to main pump 70sqmm/3core cable (2 Run), supply of panel to jockey pump 25sqmm/3core, supply of diesel panel to engine control panel 2.5sqmm/10core, supply of 70sqmm gland, supply of 25sqmm gland, supply of 70sqmm lugs, supply of 25 sqmm lugs, supply of 2.5 sqmm/10core gland, supply of dressing material etc. complete all as per standard specification and as directed by Engineer-in-charge.
Supplying and erecting of pre-fabricated MS structural steel supports such as angle, channel, plate etc. confirming to relevant IS standards for laying above ground hydrant pipes in Pump Room, Raiser, Yard Hydrant and Sprinkler System etc. complete as per standard specifications and as directed.
Material and labour for providing Sight Glass 100 mm at alocations where directed complete all as directed.
Providing, fixing, testing and commissioning of spring loaded relief valve suitable for pressure of 16 Kg/sq.cm including flanges, nuts, bolts and washers etc., including painting etc. complete all as per standard specification and as directed.
Providing, fixing, testing and commissioning of quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat and water bammer effect, upright type and temperature rating 68 deg C complete all as specified and directed.
Providing, fixing, testing and commissioning of quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat and water bammer effect, sidewall type and temperature rating 68 deg C complete all as specified and directed.
Providing, fixing, testing and commissioning of quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat and water bammer effect, concealed type and temperature rating 68 deg C complete all as specified and directed.
Material and labour for RCC core cutting of 100 mm dia in slab, floor, wall, beam etc. with RCC core cutting machine without damaging the structure etc. complete all as per standard specification and as directed.
Material and labour for RCC core cutting of 200 mm dia in slab, floor, wall, beam etc. with RCC core cutting machine without damaging the structure etc. complete all as per standard specification and as directed.
Providing, laying, jointing and testing of NP2 class RCC Hume pipe (IS-458) to cover and overlap correct levels below ground with soil, in road crossing area in 4 places x 6 metres etc. complete all as per standard specifications and as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of ISI marked (IS 2878) fire extinguisher, carbon-di-oxide type capacity 4.5 kg, flat base including valve, discharge hose of not less than 10 mm dia, 1 metre long and complete in all respect including initial fill with CO2 gas conforming to IS-307 -1966 filled to a filling rate of not more than 0.667with provisions of wall bracket (flexed with anchor fastener) etc. complete all as per standard specifications and as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of ISI marked (IS 2878) fire extinguisher, carbon-di-oxide type capacity 2 kg, flat base including valve, discharge hose of not less than 10 mm dia, 1 metre long and complete in all respect including initial fill with CO2 gas conforming to IS-307 -1966 filled to a filling rate of not more than 0.667with provisions of wall bracket (flexed with anchor fastener) etc. complete all as per standard specifications and as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of ISI marked (IS 15683) portable ABC type fire extinguisher squeeze grip nozzle type capacity 6 kg, complete in all respect including initial fill with povisions of wall suspension bracket etc. complete all as per standard specifications and as directed by Engineer-in-charge.
Supply and installation at approved location, approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter FIRE in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (4 Nos) etc. complete all as per standard specifications and as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of following types of trolley (wheel) mounted extinguishers CO2 type fire extinguisher of 22.5 Kgs, capacity assembled out brand new cylinders with wheel valve arrangement fitted with discharge hose and horn duly charged and ready for use manufactured to IS: 2878 with ISI mark etc. complete all as per standard specification and as directed by Engineer-in-charge.
Material and labour for 2 x 1.5 sqmm copper armoured FRLS PVC cable etc. complete all as specified and directed.
Supplying and installing in position sign boards made out of 3mm thick Opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, with mirror fasteners complete all as specified and directed for signages printed "IN CASE OF FIRE USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5 cm height letters in red with white background. The size of the board shall be 25cm x 30cm and shall be fixed at the height of 2 mtr from finished floor near manual call points.
Supplying and installing in position sign boards made out of 3mm thick Opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, with mirror fasteners complete all as specified and directed for floor indentification signage (ie. GROUND FLOOR, FIRST FLOOR, SECOND FLOOR etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from background and size shall be 15 cm x 60 cm.
Supplying and installing in position sign boards made out of 3mm thick Opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, with mirror fasteners complete all as specified and directed for signage of "FIRE EXTINGUISHER" to be pasted immediately above the every extinguisher, sticker type.
Supplying and installing in position sign boards made out of 3mm thick Opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, with mirror fasteners complete all as specified and directed for signage of "FIRE HYDRANT & HOSE REEL" to be pasted on door of every fire shaft at all floors, sticker type.
Supplying and installing in position sign boards made out of 3mm thick Opaque PVC foam board with computer cut, PVC non-reflective self ahesive vinyl painted foam board, with mirror fasteners complete all as specified and directed for sign board of "ASSEMBLY POINT" complete with 1mm thick rigid plastic board size of 400mm x 300mm to be fixed on ground by the using a steel rod/ pipe at designated places as per drawing.
Supplying and installing in position signages of "FIRE ORDER" containing the following matter on 3mm thick Opaque PVC foam board of computersied cut, PVC non-reflective self adhesive vinyl painted foam board of 3' x 4', Type-I comprising of the following: (A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. (B) EVACUATE THE OCCUPANTS BY USING FIRE EXISTS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VAIROUS ASSEMBLY POINTS. (C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST/ SUITABLE PORTABLE EXTINGUISHER OF WATER FROM NEAREST WET RISER. (D) BE CLAM AND DO NOT GIVE ANY ROOM FORM PANIC, WALK, DO NOT RUN. (E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
Supplying and installing in position signages of "FIRE ORDER" containing the following matter on 3mm thick Opaque PVC foam board of computersied cut, PVC non-reflective self adhesive vinyl painted foam board of 3' x 4', Type-II comprising of the following: (I) ACTION BY SECURITY/RECETION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM (A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. (B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: xxxxxxxxxxxxxxxxxx (C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. (D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. (E) IN CASE OF THE CASUALITIES, CALL AMBULANCE BY DIALLING NUMBER: xxxxxxxxxxxxxxxxx (II) TOTAL BUILDING PLAN (EVACUATION PLAN FOR INDIVIDUAL FLOOR IN 25'' x 25" SIZE BOARDS
Supply and fix In-Vessel organic composting machine (capacity- 150 kg) consisting of In-Vessel Reactor with geared motor, heating system, provision for aeration- blower, manual feeding door, sliding gate for outlet, temperature controller, control panel complete all as specified and directed.
NOTE : Amount of credit of Rs. 7070609.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 74(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
SOOD ASSOCIATES PVT LTD
Hariom Projects Pvt Ltd
Idustrial products India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid