Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.4 Cr+₹56.8 L (31.8%)Admitted-Finance 2277 RAJA PARK RANI BAGH RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹2.4 Cr+₹56.8 L (31.8%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Qualified |
| 4 | Rejected-Technical 1ST FLOOR FLAT NO 103 SCHEME NO 51 234 AVANTIKA NAGAR INDORE INDORE MADHYA PRADESH 452006 | INDORE | MADHYA PRADESH | 452006 | - | - | Rejected-Technical Not Qualified |
| 5 | Rejected-Technical 173 SHAMLI SHIV VIHAR RAIL PAR SHAMLI UTTAR PRADESH 247776 | SHAMLI | UTTAR PRADESH | 247776 | - | - | Rejected-Technical Not Qualified |
| Sl No | Description | Qty | Unit | Budhiraja Electricals L1 | Advanced Sport Technologies LLP L2 |
|---|---|---|---|---|---|
| 1.00LED SPORTS LIGHTS FOR GROUND (Two Grounds) | |||||
| 1.01 | SITC of high-quality integrated LED Flood Lights with a typical system wattage of 1000 W with a nominal system efficacy >100Lm/W. Luminaire should have CCT of 5700K with SDCM <5 and CRI 80 with different beam angle. The housing should be of non-corrosive high pressure die-cast aluminum to stand with extreme environments, having corrosion resistant powder coating with lifetime of 50K hours@L70. The Ingress protection should be minimum IP66 with IK rating of 07. The luminaire should have a 10 KV /5 KA SPD in the luminaire, with PF >0.95 & THD<10%. The SPD should comply to IEC 61643. The luminaries should be designed with optimum heat exchanger and fins in order to ensure optimum thermal dissiaption. The Drivers should be a potted driver and with aluminium casing and mounted inside the luminaire | 170 | Nos | 37,750 ₹75,72,650 Lowest | 58,800 ₹1,17,95,280 |
| 1.02 | SITC of motorized climbing mechanism ie manrider unit for accessing the head frame for repair /maintenance purpose like free fall arrester /overload protection etc. the unit shall be suitable for safe load carrying capacity of 300kg with clip speed not exceeding 9 m/min The unit shall be of galvanized steel construction with twin cage arrangement along with spring loaded wheels encasing the mast shaft for proper balancing and avoid swaging of cage while climbing suitabley rated motor and double drum winch shall be installed in the base of high mast. Main rider unit shall be common for all high mast as per drawing and specification duly vetted and approved by the engineer in charge. | 2 | Complete Job | 2,45,000 ₹5,78,200 Lowest | 12,75,000 ₹30,09,000 |
| 1.03 | NS) Supply and Laying of 1.1kv grade 3 core*2.5 sq mm copper conductor PVC / XLPE insulated un- armoured and PVC sheathed flexiable cable in between high mast DB/CG rack and luminaries including accessories. | 6,720 | RM | 282 ₹22,36,147.2 | 135 ₹10,70,496 Lowest |
| 1.04 | NS) SITC of outdoor type Highmast Lighting
Distribution board (HMLDB), along with control gear rack (CGR) fully compartmentalized cubical type made out of 2mm thick CRCA Sheet having IP65 protection with canopy, pedestal mounted, suitable for use on 415V 3Phase 4wire 50 HZ and complete with powder coated painting, of suitable size for accommodating the following component, Including providing detachable gland plate for incoming and outgoing cables entry, erected on cement concrete foundation made, complete with painting, interconnections, earthing, complete as required erected on Cement concrete foundation. HMLDB and CGR shall be installed near the base of High mast.
High mast lighting distribution board : BUSBAR: 150A rating TP & N AL Bus bar. INCOMER:- 1No.125A, 4P, MCCB(25kA) with thermomagnetic releases and all required
accessories
1 Set phase indication lights (R,Y,B) Solid state type (LED).
1 Set of push buttons for ON/OFF and selector
switch
1No. 0 to 500V, AC, digital Volt Meter & control
MCB
1 No. 0 to 125A, digital Ammeter with CT's of ratio 150/5A and class-1 accuracy OUTGOINGS:-
32 A DP MCB (16kA) with themno-magnetic releases - 21 Nos.
Winch motor starter with power contactors
,forward, reverse push button control, bypass facility in case of manual operation, overload tripping as per manufacturer’s recommendation and approved drawings. | 8 | Nos. | 1,54,000 ₹14,53,760 | 1,02,000 ₹9,62,880 Lowest |
| 1.05 | NS) Supply, installation testing and commissioning of Outdoor Double Door Kiosk type weather proof distribution feeder pillar box of suitable size with a tapered at top (for protection from rain water) and made out of not less than 2.0 mm thick for load bearing members & 1.6 mm thick for doors, compartmentalized, IP 65, epoxy powder coated treated in 7 tank process finish with following items, front and back both side openable, duly hinged doors with locking arrangement by providing both sides hold drafts and all hardware for fabrication of box. The cubical panel should be mounted with hardware on angle iron frame long legs duly primered and black painted. Frame be grouted with cement concrete 1:3:6 ratio and providing brick masonry along angle iron frame above ground level complete with connecting strips, Bakelite sheet, earth stud etc. cable entry from bottom suitable for 3.5Cx 240/120/70 Sq.mm I/c & O/g respectively. The panel should comprise of as per following (Panel shall be fabricated in CPRI approved panel builder with approval of the IWD. Drawing of the High Mast feeder pillar shall be submitted for approval prior to fabrication.
INCOMER
300 A, 4P, 36 KA TM Release MCCB with rotary
handle - 1 No. (Make: Havells, ABB,
Siemens,L&T)
350 A, TPN Aluminum bus bar.
OUTGOING (Make: Havells, ABB, Siemens,
L&T)
150 A 4P 25 KA TM Release MCCB rotary
handle- 4 Nos
Digital multifunction meter- I set
LED- RYB indicator lamps- 1 set
CT-400/5A, Class-1, 15 VA - 3nos
Control circuit MCB of adequate rating | 2 | Nos. | 1,73,729 ₹4,10,000.44 Lowest | 2,03,000 ₹4,79,080 |
| 1.06 | NS) Applying on steel structural elements 210 DFT anti-corrosive protection PU coating using Jotun paint / Akzonoble or approved equivalent with first coat of primer with Penguard HSP/ Interseal 1052, 150 microns thick and final two coat of polyurethane paint with Hardtop XP/Interthane 990, white 60 microns thick of which first coat shall be at ground and second coat after erection including touching of damaged portion of the already painted surface if any, upto all heights including preparation of surface with grit/sand blasting upto Sa 2.5 grade (at least) of the structural steel member and thorough cleaning of the surface to the satisfaction of the Engineer-in-Charge including all scaffolding, safety measures, tools and plants as per manufacturer’s recommendations and specifications and as per the directions of Engineer-in-Charge all complete.
(Note: The work shall be executed as per manufacturer's specifications wherever applicable, relevant code of practice and sound engineering practice). | 120 | Sqm | 3,898 ₹5,51,956.8 | 350 ₹49,560 Lowest |
| 2.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. | |||||
| 2.01 | All kind of Soil Footing | 192 | Cum | 136 ₹30,812.16 Lowest | 150.4 ₹34,074.62 |
| 2.02 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.8) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Under Footing & Plinth Beam)
a) Footings (4m +.150m) | 20.67 | Cum | 5,508 ₹1,34,343.42 | 4,411 ₹1,07,586.94 Lowest |
Tender Value
Refer Docs
EMD Value
₹7.5 L
Closing Date
2 Jul 2025, 3:00 pmClosed
DD INFRA
SAI HQ NEW DELHI
TENDER FOR REPLACEMENT OF WARMUP AND THROWING AREA LIGHTS WITH LED AT JLN STADIUM, NEW DELHI
2025_SAI_862663_1
SAI/INFRA/ENGINEERING WING/004/25-26
Open Tender
Construction Works
Item Rate
NEW DELHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7.5 L
Yes
12 Jul 2025
31 May 2025
3 Jul 2025
31 May 2025
2 Jul 2025
4 Jun 2025
31 May 2025 - 4 Jun 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1LED SPORTS LIGHTS FOR GROUND (Two Grounds) | |||||
| 1.01 | SITC of high-quality integrated LED Flood Lights with a typical system wattage of 1000 W with a nominal system efficacy >100Lm/W. Luminaire should have CCT of 5700K with SDCM <5 and CRI 80 with different beam angle. The housing should be of non-corrosive high pressure die-cast aluminum to stand with extreme environments, having corrosion resistant powder coating with lifetime of 50K hours@L70. The Ingress protection should be minimum IP66 with IK rating of 07. The luminaire should have a 10 KV /5 KA SPD in the luminaire, with PF >0.95 & THD<10%. The SPD should comply to IEC 61643. The luminaries should be designed with optimum heat exchanger and fins in order to ensure optimum thermal dissiaption. The Drivers should be a potted driver and with aluminium casing and mounted inside the luminaire | - | Nos | 1.25 | - |
| 1.02 | SITC of motorized climbing mechanism ie manrider unit for accessing the head frame for repair /maintenance purpose like free fall arrester /overload protection etc. the unit shall be suitable for safe load carrying capacity of 300kg with clip speed not exceeding 9 m/min The unit shall be of galvanized steel construction with twin cage arrangement along with spring loaded wheels encasing the mast shaft for proper balancing and avoid swaging of cage while climbing suitabley rated motor and double drum winch shall be installed in the base of high mast. Main rider unit shall be common for all high mast as per drawing and specification duly vetted and approved by the engineer in charge. | - | Complete Job | - | - |
| 1.03 | NS) Supply and Laying of 1.1kv grade 3 core*2.5 sq mm copper conductor PVC / XLPE insulated un- armoured and PVC sheathed flexiable cable in between high mast DB/CG rack and luminaries including accessories. | - | RM | 100 | - |
| 1.04 | NS) SITC of outdoor type Highmast Lighting
Distribution board (HMLDB), along with control gear rack (CGR) fully compartmentalized cubical type made out of 2mm thick CRCA Sheet having IP65 protection with canopy, pedestal mounted, suitable for use on 415V 3Phase 4wire 50 HZ and complete with powder coated painting, of suitable size for accommodating the following component, Including providing detachable gland plate for incoming and outgoing cables entry, erected on cement concrete foundation made, complete with painting, interconnections, earthing, complete as required erected on Cement concrete foundation. HMLDB and CGR shall be installed near the base of High mast.
High mast lighting distribution board : BUSBAR: 150A rating TP & N AL Bus bar. INCOMER:- 1No.125A, 4P, MCCB(25kA) with thermomagnetic releases and all required
accessories
1 Set phase indication lights (R,Y,B) Solid state type (LED).
1 Set of push buttons for ON/OFF and selector
switch
1No. 0 to 500V, AC, digital Volt Meter & control
MCB
1 No. 0 to 125A, digital Ammeter with CT's of ratio 150/5A and class-1 accuracy OUTGOINGS:-
32 A DP MCB (16kA) with themno-magnetic releases - 21 Nos.
Winch motor starter with power contactors
,forward, reverse push button control, bypass facility in case of manual operation, overload tripping as per manufacturer’s recommendation and approved drawings. | - | Nos. | 53 | - |
| 1.05 | NS) Supply, installation testing and commissioning of Outdoor Double Door Kiosk type weather proof distribution feeder pillar box of suitable size with a tapered at top (for protection from rain water) and made out of not less than 2.0 mm thick for load bearing members & 1.6 mm thick for doors, compartmentalized, IP 65, epoxy powder coated treated in 7 tank process finish with following items, front and back both side openable, duly hinged doors with locking arrangement by providing both sides hold drafts and all hardware for fabrication of box. The cubical panel should be mounted with hardware on angle iron frame long legs duly primered and black painted. Frame be grouted with cement concrete 1:3:6 ratio and providing brick masonry along angle iron frame above ground level complete with connecting strips, Bakelite sheet, earth stud etc. cable entry from bottom suitable for 3.5Cx 240/120/70 Sq.mm I/c & O/g respectively. The panel should comprise of as per following (Panel shall be fabricated in CPRI approved panel builder with approval of the IWD. Drawing of the High Mast feeder pillar shall be submitted for approval prior to fabrication.
INCOMER
300 A, 4P, 36 KA TM Release MCCB with rotary
handle - 1 No. (Make: Havells, ABB,
Siemens,L&T)
350 A, TPN Aluminum bus bar.
OUTGOING (Make: Havells, ABB, Siemens,
L&T)
150 A 4P 25 KA TM Release MCCB rotary
handle- 4 Nos
Digital multifunction meter- I set
LED- RYB indicator lamps- 1 set
CT-400/5A, Class-1, 15 VA - 3nos
Control circuit MCB of adequate rating | - | Nos. | 10 | - |
| 1.06 | NS) Applying on steel structural elements 210 DFT anti-corrosive protection PU coating using Jotun paint / Akzonoble or approved equivalent with first coat of primer with Penguard HSP/ Interseal 1052, 150 microns thick and final two coat of polyurethane paint with Hardtop XP/Interthane 990, white 60 microns thick of which first coat shall be at ground and second coat after erection including touching of damaged portion of the already painted surface if any, upto all heights including preparation of surface with grit/sand blasting upto Sa 2.5 grade (at least) of the structural steel member and thorough cleaning of the surface to the satisfaction of the Engineer-in-Charge including all scaffolding, safety measures, tools and plants as per manufacturer’s recommendations and specifications and as per the directions of Engineer-in-Charge all complete.
(Note: The work shall be executed as per manufacturer's specifications wherever applicable, relevant code of practice and sound engineering practice). | - | Sqm | 11 | - |
| 2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. | |||||
| 2.01 | All kind of Soil Footing | - | Cum | 10 | - |
| 2.02 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.8) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (Under Footing & Plinth Beam)
a) Footings (4m +.150m) | - | Cum | 22 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.39 MB
Tenderdocument.pdf
Tender Documents • 1.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .