Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.4 LAccepted-Finance | ₹82.4 L | L1 | Accepted-Finance OK |
| 2 | L2₹89.3 L+₹6.9 L (8.31%)Accepted-Finance | ₹89.3 L+₹6.9 L (8.31%) | L2 | Accepted-Finance OK |
| 3 | L3₹92.4 L+₹10.0 L (12.1%)Accepted-Finance | ₹92.4 L+₹10.0 L (12.1%) | L3 | Accepted-Finance OK |
| 4 | L4₹96.1 L+₹13.7 L (16.6%)Accepted-Finance | ₹96.1 L+₹13.7 L (16.6%) | L4 | Accepted-Finance OK |
| 5 | L5₹96.8 L+₹14.4 L (17.5%)Accepted-Finance | ₹96.8 L+₹14.4 L (17.5%) | L5 | Accepted-Finance OK |
| Sl No | Description | Qty | Unit | Navjeet Industries L2 | PS ELECTRICALS L6 | Vashu Enterprises L7 | AAYANSH ELECTRICAL SOLUTIONS L4 | M/s HINDUSTAN ENGINEERS L3 | Saraswati Electricals & Contractors L1 | SANJAY POWER PROJECTS PVT LTD L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Erection of PCC Pole 8.5/11 MTR. Long Single Pole with All Accessories complete in All Respect as per RESSPO Norms with cartage from store to site. | 496 | Nos | 3,350 ₹16,61,600 | 4,500 ₹22,32,000 | 7,000 ₹34,72,000 | 4,500 ₹22,32,000 | 3,250 ₹16,12,000 Lowest | 4,000 ₹19,84,000 | 4,500 ₹22,32,000 |
| 2.00 | Concreting /Grouting of PCC Pole 8.5/11 Mtr. Long (with material) of support up to ground level including back filling and ramming as per RESSPO specification. with cartage from store to site. | 496 | Nos | 670 ₹3,32,320 | 650 ₹3,22,400 | 1,500 ₹7,44,000 | 350 ₹1,73,600 Lowest | 1,200 ₹5,95,200 | 600 ₹2,97,600 | 2,000 ₹9,92,000 |
| 3.00 | Fixing & commissioning of 11 KV VCB O/G CTR 400/200/5A 350MVA with all connection properly including all required material for above work with cartage from store to site. | 1 | Nos | 20,100 ₹20,100 | 7,800 ₹7,800 Lowest | 15,000 ₹15,000 | 12,000 ₹12,000 | 15,000 ₹15,000 | 14,000 ₹14,000 | 15,000 ₹15,000 |
| 4.00 | Fixing & commissioning of 33 KV VCB O/G CTR 1250 AMP with all connection properly including all required material for above work with cartage from store to site. | 1 | Nos | 20,100 ₹20,100 | 8,500 ₹8,500 Lowest | 20,000 ₹20,000 | 15,000 ₹15,000 | 15,000 ₹15,000 | 14,000 ₹14,000 | 15,000 ₹15,000 |
| 5.00 | Laying and stringing of ACSR Rabbit Conductor complete in all Respect with cartage from store to site. | 19,890 | Mtr | 27 ₹5,37,030 | 3 ₹59,670 Lowest | 15 ₹2,98,350 | 12 ₹2,38,680 | 20 ₹3,97,800 | 20 ₹3,97,800 | 14 ₹2,78,460 |
| 6.00 | Laying and stringing of ACSR Weasel Conductor complete in all Respect with cartage from store to site. | 19,216 | Mtr | 27 ₹5,18,832 | 3 ₹57,648 Lowest | 12 ₹2,30,592 | 12 ₹2,30,592 | 20 ₹3,84,320 | 20 ₹3,84,320 | 12 ₹2,30,592 |
| 7.00 | Fixing of Stay Set Complete & Stay Wire with cartage from store to site | 109 | Nos | 670 ₹73,030 | 150 ₹16,350 Lowest | 700 ₹76,300 | 400 ₹43,600 | 1,000 ₹1,09,000 | 500 ₹54,500 | 500 ₹54,500 |
| 8.00 | Fixing of 11 KV X Cross Arm Various Type with cartage from store to site. | 300 | Nos | 268 ₹80,400 | 210 ₹63,000 | 150 ₹45,000 | 450 ₹1,35,000 | 400 ₹1,20,000 | 100 ₹30,000 Lowest | 150 ₹45,000 |
| 9.00 | Fixing of 11 KV Polymeric Pin Insulator with Pin with cartage from store to site. | 1,056 | Nos | 12 ₹12,672 | 50 ₹52,800 | 50 ₹52,800 | 10 ₹10,560 | 110 ₹1,16,160 | 2 ₹2,112 Lowest | 50 ₹52,800 |
| 10.00 | Fixing of 11 KV Polymeric Disc Insulator with fiiting with cartage from store to site. | 180 | Nos | 12 ₹2,160 | 80 ₹14,400 | 60 ₹10,800 | 10 ₹1,800 | 300 ₹54,000 | 2 ₹360 Lowest | 50 ₹9,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
10 Jun 2026, 2:00 pmClosed
SUPERINTENDING ENGINEER
33/11 KV SUBSTATION KOYAL ENCLAVE GDA BHOPURA GZB
Strengthening of 33/11 KV line, strengthening of LT line and other works UNDER EDD-I LONI
2026_PVVNL_1156274_1
T-05/W/EDC/LONI/GZB/2026-27
Open Tender
Electrical Works
Item Wise
365 days
EDD-I LONI
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Yes
SUPERINTENDING ENGINEER EDC LONI
₹1.1 L
Yes
19 Jun 2026
1 Jun 2026
10 Jun 2026
1 Jun 2026
10 Jun 2026
1 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Erection of PCC Pole 8.5/11 MTR. Long Single Pole with All Accessories complete in All Respect as per RESSPO Norms with cartage from store to site. | 496 | Nos | - | - |
| 2 | Concreting /Grouting of PCC Pole 8.5/11 Mtr. Long (with material) of support up to ground level including back filling and ramming as per RESSPO specification. with cartage from store to site. | 496 | Nos | - | - |
| 3 | Fixing & commissioning of 11 KV VCB O/G CTR 400/200/5A 350MVA with all connection properly including all required material for above work with cartage from store to site. | 1 | Nos | - | - |
| 4 | Fixing & commissioning of 33 KV VCB O/G CTR 1250 AMP with all connection properly including all required material for above work with cartage from store to site. | 1 | Nos | - | - |
| 5 | Laying and stringing of ACSR Rabbit Conductor complete in all Respect with cartage from store to site. | 19,890 | Mtr | - | - |
| 6 | Laying and stringing of ACSR Weasel Conductor complete in all Respect with cartage from store to site. | 19,216 | Mtr | - | - |
| 7 | Fixing of Stay Set Complete & Stay Wire with cartage from store to site | 109 | Nos | - | - |
| 8 | Fixing of 11 KV X Cross Arm Various Type with cartage from store to site. | 300 | Nos | - | - |
| 9 | Fixing of 11 KV Polymeric Pin Insulator with Pin with cartage from store to site. | 1,056 | Nos | - | - |
| 10 | Fixing of 11 KV Polymeric Disc Insulator with fiiting with cartage from store to site. | 180 | Nos | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
pdf5.pdf
Tender Documents • 0.88 MB
BOQ_2166371.xls
BOQ • 4.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .