Loading…
Loading…
Tender Value
₹13.9 Cr
EMD Value
₹8.4 L
Closing Date
3 Feb 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TENDER
15 conditions · 4 needing a document upload
Financial Eligibility Criteria: Financial Eligibility Criteria: Shall be as per Para 10.2 of Advance Correction Slip No. 1 dtd 14-07-2022 of GCC April - 2022. The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderer shall submit requisite information as per Annexure - VIB, along with copies of Audited Balance Sheet duly certified by the Chartered Accountant / Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria - Shall be as per Para 10.1 of GCC April - 2022. a)The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender. b)In case of composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completedor substantially completedany of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(i) : Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 (a) (ii) of Part-II of GCC or through subcontractor fulfilling the requirements as per clause 7 of Part-II of GCC or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing
However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 1.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. NOTE: The definition of "Similar Nature of Work" for this work is as under:- "Any Indoor or combined Indoor & Outdoor Signalling work including Design, Supply, Installation testing and commissioning of Electronic interlocking system for passenger carrying lines." OR "Any Indoor or combined Indoor & Outdoor Signaling work including Supply, Installation testing and commissioning of relay interlocking (RRI/PI) system/ABS/IBS for passenger carrying lines."
•Works executed for Central /State Govt. /Semi Govt. organizations Authorities, PSUs and Govt. of India Undertaking, will be considered for assessing the suitability of tenderers. Authentic certificates from the concerned Government authorities shall be produced by the tenderer(s) to this effect, along with the tender offer. •The subcontractor engaged by main contractor / concessionaires / SPVs who executed work for a Central /State Govt. /Semi Govt. Organization /Authorities /PSUs and Govt. of India undertakings will be considered for assessing the suitability, provided authentic certificate is issued by the concerned Government Authorities., subject to followings : (i)For Sub -Contractor of Concessionaires /SPV's, the similar work given by the Concessionaires /SPV's to the Sub-contractor will be considered as completed single similar work for eligibility. (ii) For all other Sub-Contractors: (a)For linear works of Railways, Roads, Canals and Dams only, similar work given to the subcontractor will be considered as completed single similar work for eligibility. (b)For all other contractors, works given to the subcontractor will be considered for eligibility only if the entire work awarded to the main contractor is physically completed and subcontractor completes the similar work allotted to him. •Total value of similar nature of work completed during the qualifying period, and not the payments received within the qualifying period alone, shall be considered. •In case, the final bill of the similar nature of work has not been passed and final measurement has not been recorded, the paid amount including statutory deductions will be considered. If the final measurements have been recorded and work has been completed with negative variation then also the paid amount including statutory deductions will be considered. However, if final measurements have been recorded and work has been completed with positive variation but variation has not been sanctioned, original agreement value or last sanctioned agreement value, whichever is lower shall be considered for judging eligibility. •Value of a completed work done by a member in all earlier Partnership firm or JV firm shall be reckoned only to the extent of the concerned member's share in that Partnership firm /JV firm for the purpose of satisfying his compliance of the above mentioned condition, in the tender consideration. •Tenderers should submit clear certificate(s) giving name of the contractor, PAN No., description of work, organization for whom executed agreement no. & date, approximate value of contract at the time of award, date of schedule completion of work, date of actual start, date of actual completion (as recorded in MB), date of final measurement, date of final bill and final value of contract & working report issued by an officer of rank not below JAG in - charge of work, separate certificate should be submitted for every single similar work. Certificates must also contain name, postal address & telephone / FAX No. of issuing authority.
4 conditions · 2 needing a document upload
As per Tender Document.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
As per Tender Document.
Supply, Installation, Testing & commissioning of Indoor & Outdoor equipment's and Provision of Electronic Interlocking at Sainagar Shirdi Station in connection with provision of 5 stabling line in Pune Division of Central Railway.
SUR-NC-CR-SNT-C-S-01-2026~CR
SUR-NC-CR-SNT-C-S-01-2026
Open
Works - General
8 Months
Jalgaon, Maharashtra
₹0
₹8.4 L
3 Feb 2026
10 Jan 2026
20 Jan 2026
561 items across 5 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 11,27,23,617.02 | ||
| — | 115.00 | — | — | ||
| Design, manufacture and supply of Electronic Interlocking (EI) system (Hot Standby) architecture complete as per RDSO specification No.RDSO/SPN/192/2019 Ver. 2.0 / RDSO/SPN/203/2011 ver. 1.0 with latest amendment or latest version or latest specifications. RDSO Technical Advisory Note No.STS/E/TAN/3012 Ver. 4.0 dated 23.07.2025 or latest regarding Technical system Application Approval for Electronic Interlocking (EI) installations, STS/SSI/General dated 07.12.2018 TSAA as per the technical requirements and tentative approved Signaling Plans & Diagrams with OEMs specifications. Electronic Interlocking (EI) system mainly consisting of Central Processing Equipment, Interface Equipments and all types of required Relays, EI racks etc. as per requirements, dual operator Industrial Grade Embedded PC (as per CI 5.3.2 of RDSO specification or latest) with VDU panel (52" LED 2 nos. or bigger) with Redundancy as per the RDSO technical advisory Note No.STS/E/TAN/3007 Version 1 dt. 02.112.12 or latest (Hot standby dual VDU Normally one system will be online and other system will be in standby mode), All types of required relays suitable for EI, interconnecting cables and jumper wires. It also includes provision of Industrial grade maintenance Terminals (as per CI 5.3.2 and 7.2 of RDSO specification or latest) (42" LED or Bigger with UPS minimum 2 hr back up), required power supply DC-DC converters for EI equipments, Housing for EI equipments and enclosures, fuses, screw less disconnecting type terminals, fixture mounting arrangements and accessories necessary make the EI system functional as per approved signaling plan."It does not include supply of Data logger , however Protocol Convertor for Data logger to be supplied. The tenderer should furnish complete details of cards/modules/sub-modules connectors, relays etc, for each station. For System ""A & B"" segregation between theDC-DC convereters should be made so that in case of failure only one system is affected. The system design shall incorporate details of approved SIP and its subsequent alteration/modification till its commissioning. It included supply of essential spares of the EI modules at 10% - Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/module, interface relays, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. FOR ------------------------- STATION." A) 20 TO 50 ROUTES. (Inspection by RDSO) | — | — | — | 7,06,23,843.7 | |
| — | 1.00 | — | — | ||
| Supply of tool kit- required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations as per schedule item 1 above. (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose plier etc. & measuring instruments with carrying case/ holders/cabinet for technicians/ J.E. or testing, Maintenance and repair at site). Each set comprises of the following (a) Crimping tools for all types of special cable assembly used in EI system. (b) Insertion tool for all types of special cable assembly used in EI system. (c ) Removal tools for all types of special cable assembly used in EI (d) Digital multimeter (Tektronics/Fluke/MEGGER/RISHAV or better) system. (e) Steel cabinet / Almira (Godrej/Durian/Transteel) of good quality to store tool, spare cards and documents. (f) Clamp Earth Tester. (Fluke 287/MEGGER/RISHAV or better) (g) Clamp Current Meter. (Fluke 287/MEGGER/RISHAV or better) (h) 6 nos. Electrostatic Discharge Wrist Band for cards modules protection. ( (Inspection by consignee) | — | — | — | 1,25,155.52 | |
| — | 1.00 | — | — | ||
| Supply of as made documents (Manuals for Installation, Testing, and maintenance of the system) (One set consists of 6 set of following drawings per station). (i) Manual for installation, Testing, Commissioning and maintenance of the system for Technicians/Jr. Engineers. (Installation and maintenance level ) (ii) Functioning and system overview (Higher Management Level) (iii) Completion documents as per special conditions of contract. (iv) Design & supply of circuits and plans to suit layout given in the signaling plan for Hot Standby Architecture Electronic Interlocking (EI) system. All plan and wiring diagram shall be prepared on AutoCAD Drawing and supplied with C D . This will include supply of Control-cum-Indication Panel/VDU diagram, Square sheet, wiring diagrams (Application Logic and Interface circuit), Fuse Analysis, Contact Analysis, Tag Block Analysis, Power supply Distribution / Power Equipment arrangement (with program switch) Diagram, Auto change over diagram (if supplied by the contractor), and all other relevant drawings. NOTE : The contractor shall initially supply 1 set of documents (Paper Prints) for approval of Railways. He shall ensure that each sheet has a block for signature of Railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. After approval of comments by Railways, the Contractor will make copies of the approved documents and return the approved documents to Railways. The contractor will then make necessary correction to Application Logic Software duly incorporating Railways' alterations/corrections/comments, if any. After complete testing/ commissioning of the station, tracings of completion documents as mentioned above will be submitted to Railways for approval. Along with the completion application logic, difference report (showing addition & deletion in different colors) as compared to earlier approved application logic should also be submitted. After approval of completion application logic by Railways, 5 sets of copies of duly approved completion tracings will be submitted to Railways. (Inspection by consignee) | — | — | — | 1,58,869.3 | |
| — | 1.00 | — | — | ||
| Supply of Portable work station for Data input & configuration with necessary software/AutoCAD latest version programmes/Accessories, simulation and functional Testing, diagnostics and trouble shooting and commissioning of EI system. Suitable Table & Chair or reputed make shall be supplied by the contractor. The specifications of the PC / Laptop should be got approved from the Engineer in charge before supply. Note : Portable work station should strictly adhere to specification as per annexure. (Inspection by consignee) | — | — | — | 1,73,081.22 | |
| — | 1.00 | — | — | ||
| Modification in existing EI system as per latest TAN, it includes:- Design and modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP, MT, Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signaling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses etc.) The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies (6 sets.)NOTE : If the alteration involves modification of routes up to 10, fixed cost as per the Rate mentioned in (i) above shall be paid. If the alteration involves modification of routes are more than 10 up to 20 routes, then, fixed cost as per the Rate mentioned in (ii) above shall be paid. i) Alteration involving modification in more than 11 and up to 20 routes (Inspection by RDSO) | — | — | — | 26,23,308.74 | |
| — | 4.00 | — | — | ||
| Supply of Relay rack assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 way Bus bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure and Rack arrangement as per sketch no SK-727 and Rack plan as approved by Engineer in charge.(Inspection by consignee) | — | — | — | 1,43,134 | |
| — | 5.00 | — | — | ||
| Supply of Main cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure and rack arrangement shall be as per sketch No.SK-727 with latest alterations.(Inspection by consignee) | — | — | — | 1,53,435.4 | |
| — | 1.00 | — | — | ||
| Supply of Data logger for monitoring status of important relays, complete with processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec. No: IRS:S- 99/2006 (Amdt-3) with latest amendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module (computer) as per Annexure shall be placed in President rack of suitable size to be supplied. This also includes supply of one no. composite computer & printer table (work station table-Godrej/Durian/Transteel) for keeping processor module and one no. Godrej/Durian/Transteel make operator chair. i) 2560 digital and 32 analog inputs.(Inspection by RDSO) | — | — | — | 9,70,217.24 | |
| — | 1.00 | — | — | ||
| Multi port front end processor with two nos. of dual card modems with and 230/12V charger and 24V, 42AH maintenance free battery. SPN NO.Spc. No.: IRS:S-99/2006 (Amdt-3) or latest (Inspection by RDSO) | — | — | — | 2,33,034.66 | |
| — | 1.00 | — | — | ||
| Failure analysis software for 1024 digital and below (Inspection by RDSO) | — | — | — | 43,143.16 | |
| — | 1.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x2.5 Sq.mm (50 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.(Inspection by consignee) | — | — | — | 46,427.1 | |
| — | 1.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x6 Sq.mm (84 conductor each diameter 0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest .Inspection by consignee) | — | — | — | 89,846.38 | |
| — | 2.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. ( Inspection by consignee) | — | — | — | 2,81,363.92 | |
| — | 2.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. Inspection by consignee) | — | — | — | 4,17,984.32 | |
| — | 2.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. Inspection by consignee) | — | — | — | 6,59,981.08 | |
| — | 20.00 | — | — | ||
| Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. Inspection by consignee) | — | — | — | 1,32,278 | |
| — | 160.00 | — | — | ||
| Supply of low maintenance Lead Acid secondary cells 2V 80AH as per spec. IRS 88/2004 version 1.0 with latest amendments. ( Inspection by RITES) | — | — | — | 3,10,576 | |
| — | 60.00 | — | — | ||
| Sealed maintenance free VRLA Battery/Cell 2 volt, 300AH IRS: S-93/96 (A) (Amd.1) or latest.( Inspection by RITES) | — | — | — | 2,65,854 | |
| — | 10.00 | — | — | ||
| Supply of Program switches with acrylic cover, snap action, base mounting type along with cover and mounting bracket 25A-7 pole 3 position Siemens (3 LAO-25/7Y)/ L&T/HEVELS type. Drg. No.RST.C.106.(Inspection by consignee) | — | — | — | 74,611.4 | |
| — | 10.00 | — | — | ||
| Supply of Program switches, snap action, base mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens (3 LAO-63/7Y)/L&T/HEVELS type Drg.No.RST.C.106. (Inspection by consignee) | — | — | — | 77,821 | |
| — | 1.00 | — | — | ||
| Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 110 V DC, 40 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO) | — | — | — | 90,393.9 | |
| — | 3.00 | — | — | ||
| Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC,30 A t o spec.IRS.S.86/2000 (Amndt-1) with latest amendment for Axle counter application (Amd.4) (Inspection by RDSO) | — | — | — | 1,90,413.06 | |
| — | 300.00 | — | — | ||
| Supply of Rubber Mat 5mm thick for use in signaling installation..(Inspection by consignee) | — | — | — | 39,648 | |
| — | 30.00 | — | — | ||
| Supply of Key Lock Relay with different ward combinations (Three extra set of ward plate for point Machine to be supplied with each relay). Siemens make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 version 1.0 with Amendment No.1 or latest.(Inspection by RDSO) | — | — | — | 2,81,359.2 | |
| — | 40.00 | — | — | ||
| Supply of QNA1 AC immunized relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1(Inspection by RDSO) | — | — | — | 1,58,544.8 | |
| — | 20.00 | — | — | ||
| Supply of QN1 Non AC immunized neutral relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930, IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1(Inspection by RDSO) | — | — | — | 82,765.2 | |
| — | 10.00 | — | — | ||
| Supply of QN1 Non AC immunized neutral relay, 12F-4B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1(Inspection by RDSO) | — | — | — | 45,736.8 | |
| — | 50.00 | — | — | ||
| Supply of QTA2 AC immunized track relay, 9 Ohm, 2F.1B, along with plug, board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1)(Inspection by RDSO) | — | — | — | 1,91,219 | |
| — | 10.00 | — | — | ||
| Supply of QBAT track Relay, AC immunized, 2F-2B, contacts, 9 ohms. Complete with plug, board, retaining clip and connectors as per RDSO/SPN/84 Ver. 2.0 with Amendment No.1 or latest.(Inspection by RDSO) | — | — | — | 65,265.8 | |
| — | 10.00 | — | — | ||
| Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B, AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL)(Inspection by RDSO) | — | — | — | 39,140.6 | |
| — | 10.00 | — | — | ||
| Supply of QBCA1 AC immunized relay, 2FHD 4F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:943 POINT CONTACTOR RELAY. And RS S46/74 with Amendment No.1 & firms specification(Inspection by RDSO). | — | — | — | 47,931.6 | |
| — | 10.00 | — | — | ||
| Supply of QL1 LATCH relay, 11F-4B or 8F-6B along with plug board, retaining clip and connectors conforming to BRB:935A.(Inspection by RDSO) | — | — | — | 47,270.8 | |
| — | 50.00 | — | — | ||
| Supply of QNA1K relay 1000 ohm, 6F/6B 24V DC as per BRS :931A, IRS:S60, IRSS354 & IRS:S23 and RDSO Spec. STS/E/Relays/UEA (PI) dtd.30.05.1997 Annexure II (IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1)(Inspection by RDSO) | — | — | — | 2,01,485 | |
| — | 10.00 | — | — | ||
| Supply of Desk type Electronic Magneto Telephone as per spec No. IRS TC-79/2000 (Amd.4) with Amendment No.02 or with latest amendments.(Inspection by consignee) | — | — | — | 29,511.8 | |
| — | 1.00 | — | — | ||
| Supply of Test Board & circuit progress board for relay room as per Drg No RST/C/105 A&B(Inspection by consignee) | — | — | — | 11,214.72 | |
| — | 2.00 | — | — | ||
| Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Micowave Radio.(Inspection by consignee) | — | — | — | 70,856.64 | |
| — | 2.00 | — | — | ||
| Supply of Modems for UFSBI (For use with secondary media and OFC/Quad.) (Inspection by consignee) | — | — | — | 1,31,938.16 | |
| — | 2.00 | — | — | ||
| Supply of MODEM compatible with existing UFSBI system to work on back up media (either VF channel on OFC P/Mux or 2 Mbps E1 channel from STM or direct dark single mode optic fibre cable upto 30 km distance.(Inspection by consignee) | — | — | — | 1,45,491.64 | |
| — | 200.00 | — | — | ||
| Supply of PPTC Fuse GP 60-185 UL-94 certification (1.6 Amps) for internal / external current. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc..(Inspection by RDSO) | — | — | — | 1,888 | |
| — | 200.00 | — | — | ||
| Supply of PPTC Fuse GP 60-400 UL-94 certification (12V/4A) TF, TR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc..(Inspection by RDSO) | — | — | — | 1,652 | |
| — | 200.00 | — | — | ||
| Supply of PPTC Fuse GP 30-100 (24V/1.4A) TPR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc..(Inspection by RDSO) | — | — | — | 1,652 | |
| — | 200.00 | — | — | ||
| Supply of PPTC Fuse GP 250-185 UL-94 certification (24V/4A)110V AC for track chargers. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc..(Inspection by RDSO) | — | — | — | 1,652 | |
| — | 30.00 | — | — | ||
| Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.(Inspection by consignee) | — | — | — | 38,161.2 | |
| — | 150.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs)(Inspection by consignee) | — | — | — | 10,089 | |
| — | 30.00 | — | — | ||
| Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.(Inspection by RDSO) | — | — | — | 8,19,403.8 | |
| — | 6.00 | — | — | ||
| Design, fabrication and supply of fuse Auto changeover system for 24 Nos external non detorating type fuses or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operation circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.(Inspection by RDSO) | — | — | — | 2,38,680.96 | |
| — | 15.00 | — | — | ||
| Supply of Main signal post 140 mm outer dia 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments.(Inspection by consignee) | — | — | — | 1,05,828.3 | |
| — | 5.00 | — | — | ||
| Supply of Main signal post 140 mm outer dia 5.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments.(Inspection by consignee) | — | — | — | 47,902.1 | |
| — | 20.00 | — | — | ||
| Supply of Shunt signal post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.) (Inspection by consignee) | — | — | — | 62,540 | |
| — | 20.00 | — | — | ||
| Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice.(Inspection by consignee) | — | — | — | 1,87,478.4 | |
| — | 20.00 | — | — | ||
| Supply of Cast Iron Shunt signal surface base 80 mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, as per RDSO Drg. No.SA- 23156/ Drg. No.RST/11413 as per extant C. Rly practice. (Inspection by consignee) | — | — | — | 41,347.2 | |
| — | 50.00 | — | — | ||
| Supply of Signal No.Plates as per Drg No RST-11393/ SK-842(Inspection by consignee) | — | — | — | 26,373 | |
| — | 5.00 | — | — | ||
| OFF set bracket 5-1/2" to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg No SA-23080 for signals & Routes.(Inspection by consignee) | — | — | — | 4,843.9 | |
| — | 5.00 | — | — | ||
| OFF set bracket 3-1/2' for signals & Routes. Drawing No.SA23840(Adv) Alt-2 as per extent C.Rly practice.(Inspection by consignee) | — | — | — | 24,361.1 | |
| — | 20.00 | — | — | ||
| Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment.(Inspection by consignee) | — | — | — | 11,233.6 | |
| — | 8.00 | — | — | ||
| Supply of Stop Board / IB Board as per RST-11791 (STOP BOARD)/ RDSO Drg No 7235/B as per extent C.Rly practice.(Inspection by consignee) | — | — | — | 26,082.72 | |
| — | 10.00 | — | — | ||
| Supply of different warning Board as per Goods warning Board (SK-784) RDSO Drg No. SA 2380 (Adv), SA 2370/M-, Block section limit Board RDSO Drg No. SA 2373 - Paint and retroreflective arrangement as per Railways drawing.(Inspection by consignee) | — | — | — | 32,981 | |
| — | 200.00 | — | — | ||
| Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys.(Inspection by consignee) | — | — | — | 57,820 | |
| — | 15.00 | — | — | ||
| Supply of "2 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost(Inspection by RDSO) | — | — | — | 4,57,084.8 | |
| — | 5.00 | — | — | ||
| Supply of "3 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoide any extra paint cost(Inspection by RDSO) | — | — | — | 1,57,164.2 | |
| — | 20.00 | — | — | ||
| Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps.(Inspection by RDSO) | — | — | — | 2,76,851.6 | |
| — | 2.00 | — | — | ||
| Supply of 2 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps(Inspection by RDSO) | — | — | — | 86,066.84 | |
| — | 3.00 | — | — | ||
| Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps(Inspection by RDSO) | — | — | — | 25,325.16 | |
| — | 6.00 | — | — | ||
| Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extent practice & as per instruction of Rly engineer at site DRG - No.SK- 844(Inspection by consignee) | — | — | — | 31,017.48 | |
| — | 20000.00 | — | — | ||
| Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3.(Inspection by RITES) | — | — | — | 15,34,000 | |
| — | 300.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses.(Inspection by RITES) | — | — | — | 50,976 | |
| — | 70.00 | — | — | ||
| Supply of Tik-tak, piano type switches, 5 A (as per IS Specification).(Inspection by consignee) | — | — | — | 2,478 | |
| — | 70.00 | — | — | ||
| Supply of three pole plug and socket 5 Amp (as per IS Specification).(Inspection by consignee) | — | — | — | 16,933 | |
| — | 80.00 | — | — | ||
| Supply of Lamp 110V / 24W, 2 pin for Loc.(Inspection by consignee) | — | — | — | 1,888 | |
| — | 50.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration.(Inspection by RITES) | — | — | — | 8,40,868 | |
| — | 20.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors. b) Half Case as per Drg No SK 783-1 & 2. with latest alteration.(Inspection by RITES) | — | — | — | 2,66,373.2 | |
| — | 80.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815 (Inspection by consignee) | — | — | — | 89,774.4 | |
| — | 1.00 | — | — | ||
| A CLASS EARTHING - Supply of ESR ALTEC TERRA STREAMER Lightning Arrestr with SS adaptor (TSP30, 50 Mtr. Radius) SPN : NFC-17-102-2011.(Inspection by RITES) | — | — | — | 60,706.28 | |
| — | 1.00 | — | — | ||
| Supply of Lightning strike recorder LSC 6 digit shall be weather proof type. It should have 6 digit event count & the capacity to count smallest strike (3KA). It should be voltage sensing type counter. So that it will register nearby strikes & static discharge due to induction effect. as per IS 2309:1989..(Inspection by RITES) | — | — | — | 14,239.06 | |
| — | 500.00 | — | — | ||
| Supply of 35 Sq. mm. multistrand single core PVC insulated copper for connecting earth bus bar to earth electrode.Inspection by consignee) | — | — | — | 2,15,350 | |
| — | 100.00 | — | — | ||
| Supply of copper Tape 25x6 mm (Bonding ring conducter) mounted on insulated standoff (1 round).Inspection by consignee) | — | — | — | 83,898 | |
| — | 2.00 | — | — | ||
| Supply of 300x25x6 mm Cu equipotential Bus Bar.Inspection by consignee) | — | — | — | 2,787.16 | |
| — | 5.00 | — | — | ||
| Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments.Inspection by RDSO) | — | — | — | 7,00,005.5 | |
| — | 120.00 | — | — | ||
| Supply of Track Lead juction Boxes as per C.Rly Drg.No.RST 11509 made from fiber glass alongwith terminal blocks.Inspection by consignee) | — | — | — | 1,24,324.8 | |
| — | 70.00 | — | — | ||
| Supply of B type choke amendments.Inspection by consignee) | — | — | — | 2,55,977.4 | |
| — | — | — | ) | ||
| — | 60.00 | — | — | ||
| Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments ( with phenolic moulded base).Inspection by consignee) | — | — | — | 77,101.2 | |
| — | 70.00 | — | — | ||
| Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn. No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery.Inspection by RITES) | — | — | — | 1,65,282.6 | |
| — | 10000.00 | — | — | ||
| Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3.Inspection by consignee) | — | — | — | 23,600 | |
| — | 6000.00 | — | — | ||
| Supply of PVC jacketed wire rope for Track lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed for recycled material should not be used.Inspection by consignee) | — | — | — | 3,25,680 | |
| — | 500.00 | — | — | ||
| Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@Inspection by consignee) | — | — | — | 44,250 | |
| — | 30.00 | — | — | ||
| Supply of Hydrometer, Exide make similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxses. Consignee inspection under manufacturer certificate.Inspection by consignee) | — | — | — | 8,566.8 | |
| — | 60.00 | — | — | ||
| Supply, Installation, testing and commissioning of track battery charger monitoring system for 2V/4V/6V/8V batteries with accessories at nominated stations. General scheme to be approved by Engineer-in-charge.Inspection by consignee) | — | — | — | 99,615.6 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of remote indication unit along with all accessories for above item.Inspection by consignee) | — | — | — | 2,322.24 | |
| — | 3.00 | — | — | ||
| Supply of single section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO/SPN/177/2012 Ver.03 or Latest. Each set consist of following:- a) High frequency TX coil and RX coil (Each set consist of web mounting type TX coils-2 Nos. RX coils-2 Nos along with 10 mtr cable-2 sets),b)Track side digital axle counter unit.-2 nos. c) 24V 6F/4B, 1000 ohm "Q" type relay Box duly wired - 2 Nos. d) Clamp with detector plates and hardware etc-4 Nos e) Reset Box 2 Nos ii) Mushroom/Location Box suitable for housing Track side equipment (2 Nos.) 2) Transportation, Installation testing & commissioning:- Transportation, Installation testing & commissioning of equipment field training (one man day per set) at site or as desired by site Engineer. These includes:- a) Foundation & erection of Track side Equipment i.e. Mushroom/ Location Box (If required). This includes supply of all associated materials., b) Individual Earthing of all detection Point for the OEM recommended earth value certified by OEM site engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec.no: RDSO/SPN/197/2008 or latest. Resetting equipment to the connected to the EI Ring earth. c) Installation to be carried out by OEM certified Engineer. 3) Tool Kit consisting of :-a) Digital True RMS multi meter of suitable make for above Digital Axle counter system with probe set- 1nob) Train Simulator (High frequency)-1 no c) Extender Card - 1 no d) Dummy wheel-1 no e) Different type of spanners suitable for above Digital Axle counter - 1 set f) Torque wrenches suitable for the aboe-1 no g) Screw driver set suitable for the above - 1 set. h) Carrying Bag for Tools - 1 no i) 6 nos Electrostatic Discharge Wrist Band for cards/ modules protection. (Inspection by RDSO) | — | — | — | 13,94,129.88 | |
| — | 30.00 | — | — | ||
| Supply of Digital Axle counter Multi section type complete system including the central Evaluator and final track clearance relay for each section, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specifiction No.RDSO/SPN/176/2013 (ver.3) or latest and manufacturers specification. The equipment must also include the following:I a) System must have remote monitoring and health diagnostics feature as per RDSO specification.b) Surge protection device, c) 20% spare slots for the both detection heads and track section in the evaluator for future and emergency provision. Each set also consisting of a) Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safe guard Rail contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC as per specification and other accessories (as per Annexure) e) Pre-wired cabinet/rack - No. as per site requirement. f) 6 nos. Electrostatic Discharge Wrist Band for cards/modules protection. (Inspection by RDSO) | — | — | — | 1,02,08,156.4 | |
| — | 4.00 | — | — | ||
| SUPPLY of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC(642X A programmable electronic timer switch) make. (Inspection by CONSIGNEE) | — | — | — | 11,266.64 | |
| — | 500.00 | — | — | ||
| Supply of Multi strand twin twisted core shielded cable of 28 - 30/0.2 mm for Axle counter as per IRS spec. 76/89 with Amendment No.03 or latest amendments, if any. (Inspection by RITES) (Unit Meter = Per 100 Meter) | — | — | — | 74,37,540 | |
| — | 5.00 | — | — | ||
| Supply of Pre-wired Crank Handle cum key lock relay box (of metal) alongwith LEDs, with approved type push buttons, 8-way terminal strips, string rod, etc. as per Drawing No.RST.C.114 (Inspection by CONSIGNEE) | — | — | — | 52,456.9 | |
| — | 50.00 | — | — | ||
| Supply of William stretcher nylong insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23/88 with Amendment No.01 & 40/84 with Amendment No.01 or latest amendements. (Inspection by RITES) | — | — | — | 26,668 | |
| — | 50.00 | — | — | ||
| Supply of Tongue attachment nylon insulation set consisting of one inlsulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692Inspection by RITES) | — | — | — | 16,933 | |
| — | 50.00 | — | — | ||
| Supply of Gauge Tie Plate nylong insulation as per RDSO drg No: T-10372 Alt2, T- 10368, T-10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23/88 with Amendment No.01 & 40/84 with Amendment No.01 or latest amendements.Inspection by RITES) | — | — | — | 12,213 | |
| — | 25.00 | — | — | ||
| Supply of Ground connections, complete set suitable for IRS type/appd. Point Machine for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg.S/3361@47>47?40@for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout.Inspection by RITES) | — | — | — | 2,07,031 | |
| — | 10.00 | — | — | ||
| Supply of Ground connections, complete set suitable for IRS type/appd. Point Machine for derail switch with tounge attachment insulation as per RDSO Drg.S/3361@47>47? 40@for IRS type point machine) or RDSO Drg No.SA-9151/52 with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout.Inspection by RITES) | — | — | — | 67,342.6 | |
| — | 50.00 | — | — | ||
| Supply of GI bend pipe, B class, 50mm dia for cable entry in point machine alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835.Inspection by CONSIGNEE) | — | — | — | 12,449 | |
| — | 300.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make.Inspection by RITES) | — | — | — | 3,21,432 | |
| — | 2000.00 | — | — | ||
| Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest.Inspection by RITES) | — | — | — | 6,79,680 | |
| — | 6000.00 | — | — | ||
| Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4..Inspection by CONSIGNEE) | — | — | — | 25,84,200 | |
| — | 3000.00 | — | — | ||
| Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only..Inspection by RITES) | — | — | — | 3,54,000 | |
| — | 300.00 | — | — | ||
| Supply of DIN Channel for the terminals 1 Mtrs eachInspection by CONSIGNEE) | — | — | — | 66,198 | |
| — | 300.00 | — | — | ||
| Supply of End plates for modular terminal block Inspection by CONSIGNEE) | — | — | — | 7,080 | |
| — | 600.00 | — | — | ||
| Supply of End Clamp for modular terminal block Inspection by CONSIGNEE) | — | — | — | 10,620 | |
| — | 2.00 | — | — | ||
| Operating tool (operating tool, screw driver & stripper) as per Annexure. Inspection by CONSIGNEE) | — | — | — | 17,147.76 | |
| — | 2.00 | — | — | ||
| Tool bag complete with Megger as per Annexure. ADD AC / DC clamp meter, with Hand Held Tool Bag. Inspection by CONSIGNEE) | — | — | — | 1,01,456.4 | |
| — | 1.00 | — | — | ||
| Supply of Digital measuring wheel for measuring cable trench/route make: Stanley or Freemens make or similar reputed make. Inspection by CONSIGNEE) | — | — | — | 4,550.08 | |
| — | 2.00 | — | — | ||
| CABLE ROUTE TRACER for tracing existing cable route and depth make: Stanley/MEGGER/Rycom. Inspection by CONSIGNEE) | — | — | — | 2,91,478.88 | |
| — | 100.00 | — | — | ||
| Supply of Adhesive Tapes rolls, PVC (18mm x 25 Mtr) Steel Grip/SCOTCH/ANCHOR. Inspection by CONSIGNEE) | — | — | — | 3,304 | |
| — | 20.00 | — | — | ||
| Supply of 4.5 kg CPO2 type fire extinguisher along with all accesories, extinguisher testing certificate has to be supplied along with - Supply of ISI marked Carbon Dioxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer.Inspection by CONSIGNEE) | — | — | — | 1,01,975.6 | |
| — | 1.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm control Panel with LCD display complying to RDSO/SPN/217/2025 Ver 3.1 or latest modular, 1 loop (minimum 125 detector/devices per loop-expandable to 2 loops) with 320 Character with soft keys for displaying alarm, events and operating functions, Day/Night operation function, Remote maintenance service feature etc. The panel should be multi-protocol i.e. able to support at least 2 different makes of addressable detectors. The panel should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 230 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condition. Panel should be Vds Certified. (Inspection by RDSO) | — | — | — | 65,451.06 | |
| — | 60.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. (Inspection by RDSO) | — | — | — | 1,94,558.4 | |
| — | 2.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed.(Inspection by RDSO) | — | — | — | 10,178.68 | |
| — | 400.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of Resettable, Analogue Type Liner Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed.(Inspection by RDSO) | — | — | — | 5,50,824 | |
| — | 1.00 | — | — | ||
| Suply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed.(Inspection by RDSO) | — | — | — | 1,30,655.5 | |
| — | 3.00 | — | — | ||
| — | 3.00 | — | — | ||
| — | — | — | 25,314.54 | ||
| — | 1.00 | — | — | ||
| — | — | — | 7,544.92 | ||
| — | — | — | strobe | ||
| — | 300.00 | — | — | ||
| — | — | — | 33,276 | ||
| — | 2.00 | — | — | ||
| — | — | — | 7,247.56 | ||
| — | 1.00 | — | — | ||
| — | — | — | 8,747.34 | ||
| — | — | — | 1,33,87,606.22 | ||
| — | 1.00 | — | — | ||
| Installation, testing & commissioning of EI system complying to RDSO Technical Advisory Note No STS/E/TAN/3012 Ver 2.0 dated 10.08.2016 and Supply, Installation, testing & commissioning of earthing arrangment for EI as per RDSO/SPN/197/2008 at locations/Gumtis/Cabins/EI Huts/Auto Hut of the yard, Earthing of EI equipment, relay racks and power equipment etc to be done with Class A protection, Earthing shall be in the form of perimetric/Ring Earth conforming to RDSO specification and RDSO technical advisory note for earthing and bonding scheme of EI No.STS/E/TAN/3006 Ver.1 Dt. 02.11.2012 or latest, with earth resistance less than 1 ohm. | — | — | — | 4,92,052.92 | |
| — | 24.00 | — | — | ||
| Training of Technician / Engineers/ Senior Engineer in installation, for trouble shooting & repairing, commissioning, Testing, Repairs Troubleshooting. (Hard copies of training material/ course modules to be given to each participant). | — | — | — | 18,82,090.56 | |
| — | 4.00 | — | — | ||
| Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site. | — | — | — | 5,937.76 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .