| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹46.1 L+₹6.1 L (15.2%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹46.4 L+₹6.4 L (16.0%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹53.5 L+₹13.5 L (33.9%)Rejected-Finance | L4 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
10 Jan 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE I KNHED PW Dte.
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Covid Specific infrastructure in Proposed Hybrid CCU at Ground floor CB Building under RG KAR MCH Electrical Sub Division PWD Electrical Installation work
2021_WBPWD_357442_1
WBPWD/EE/KNHED/NIQ-107/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.1 L
29 Aug 2024
23 Dec 2021
13 Jan 2022
25 Dec 2021
10 Jan 2025
25 Dec 2021
120 days
Amount
LT Cubical Panel for Hybrid CCU :-
Preperation New Feeder Piller BOX Supply & installation of outdoor type Feeder pillar box having over all dimension 2050 x 1450 x 1600 mm fixed on 50mm x 50mm x 6mm base angle channel on brick foundation. The pillar box to be made of 2 mm sheet steel should be fabricated work with necessary angle iron and flat iron duly welded bolted inside the pillar box for fixing different accessories having suitable size of angle iron for legs. The top sheet of the box (3mm) will be necessary to extend from the body of the box and also conical shape for rain water shed, it should have proper ventilation system for circulation of air and two part hinged type door with 2 nos. (Dust & Vermin proof) ,canopy arrangement for ventilation.
Railway type locking arrangement of both sides and providing 2 nos. handle for opening & closing the door. It is painted by two coats of Al. paint over one coat of R.O primer. the pillar box to be installed on brick foundation (200mm x 1800 mm x 750mm) after keeping the box on brick bedded by brick ships & thereafter bricks foundation with neat cement finishing.
Part B Supply & installation of suitable size cubical type L.T distribution panel mounted by wall cum floor. It is fabricated from 1.6mm thick rust proof CRC sheet with all necy. flat/angle support, both ends of cable end/throat box of all main switches and welded at all edges having hinged door with rubber gasket in each compartments to protect from dust & moisture Necessary interconnection with bus bar and bottom Cabel entry and side exit .
There should be approved painted inside &outside. The interconnection between incoming & outgoing main switch and bus bar by suitable size cu wire, strips and bars & also the ends by crimping arrangement. It should be comprising with the following BBC & incoming & out going mains witches.
a) 1000 Amp capacity bus bar (4 no Cu. bar on FRP insulator)
b) 415V, 630 Amp on 4 pole load Change over Switch -1 nos.(Mke-C&S ,Model-CSCS800K4CO/ L& T/ABB)
c) 415V,400 Amp SDSFU with suitable size cable end box -1 nos.)(Mke-C&S ,Model-CSCS800K4CO/ L&T/ABB) -2 Nos
c)S&F 415V,250Amp ,4 Pole ,Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make- Legrand/LT/ABB/Cabtree)MCCB (Thermal trip type)suitable size terminal spreader connection -2 nos
d)S&F 415V,200 Amp MCCB Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make- Legrand/LT/ABB/Cabtree) (Thermal trip type)suitable size terminal with spreader connection -2 Nos
d)S&F 415V,315 Amp SDSFU (Open Execution)suitable size cable end box -1 nos (Make -L&T)(Mke-C&S ,Model-CSSD315DM)
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (AVH & ICCU ,CB LIFT Panel)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
LT Cubical Panel at DG room (flor mounted Mounted on angel iron frame ) :-Supply & Installation of LT Cubicle type fully compartmentalized Floor mounted panel board of size(7'x6.5'x1.6), with multi-tier arrangement, having rigid & self supporting structure fabricated with sufficient no. of channels (50x15x15mm) and covered by 14 SWG CRCA sheet with two coated enamalled paint along with IP55 protection combined with Louver arrangement at side with base structure by 75x40x4mm channel.Cable entry at bottom of the panel & cabel exit at top of the panel with two sided cabel alley .All incoming, outgoing SFUs are to be open execution & housed in respective compartments with hinged & gasketted doors at the front.
All the doors should have panel lock arrangements in such a fashion that it can not be unlocked unless the respective feeder remains OFF. The rear of panel should have gasketted wire net guard for ventilation and arrangement shall be made for easy access to each compartment by providing rear doors with locking system. The panel is to be properly gasketted to prevent the dust & vermin. All vertical & horizontal bus-bar chambers are to be properly arranged & all electrical switches, bus-bars are to be fixed by MS nut-bolts on suitable hylam board / non-hygroscopic insulators of adequate size & dimension. The outgoing feeder connections from respective switches are to be made at the rear side by means of bus-bar / multicore copper cables, to be terminated on bolted type terminals for cable connections or bush insulators for bus connection.There should be plate for making hole to fix different size glands.
Incomer-3 PH,415 V, 400 Amp,TPN ON LOAD(front operate) Change over switch .(Make-LT/HPL) Bus-Bar Chamber :600 A 4 bar Copper BBC made of 99.99 % electrolytic tinned copper flats .The bus-bar is to be rigidly supported on suitable SMC/DMC moulded non-hygroscopic insulating materials(or FRP Chair ) of robust fashion to withstand electro- mechanical stresses in the event of earth fault. All connection to bus is to be made by suitable nut-bolts. The bus-bar is to be wrapped with heat sinkable PVC tape (Red, Yellow, Blue & Black) for identification.(Make-Birla cupper/HCL).
Outgoing- Switch disconnector fuse conformto IS :13947 ,Three pole & nutral,50 Hz AC ,415 V ,with 3 nos DIN type HBC fuse Link( Make - L&T/ABB/Siemense) -
200 Amp 4 pole SDSFU (open execution) = 4 set
Power Terminal /Connector ( 3 phase,415 V,TPN) to be fixed at cabel alley on FRP chair with proper rating against the respestive outgoing SFU.
c)R-Y-B LED Indicator Lamp =3 Nos
d)Slide Lock Fuse 20A backelite fuse base,4A HRC Fuse link(make-GE) =3 set
e)400/5A CT [make AE/Kappa] =3 set
f) Danger Board =1 no
Inter conection :-The outgoing feeder connections from respective switches are to be made at the rear side by means of rated size to be terminated onor bush insulators for bus connection or Power wiring shall be done from 95/70/50 Sq. mm flexible copper wires with Socketing & control wiring shall be done from 1.5 Sq.mm copper wires with bolted type terminals for cable connections duct,ferul, socket, etc.
Earthing :-A separate continuous aluminium earth bus-bar of size 50x5 mm is to be provided at the inside bottom of the panel and run across the full length of panel board. All electrical switches, C/O switches etc. are to be properly earthed with suitable GI wire.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ABB/Cabtree/L&T) up to 160A [ D-11 /15] i) 8 way Enclosure
ii) 6 way Enclosure
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.(Make- Legrand/ABB/Cabtree)[D-8/ 10] A) 160A (AC , Negative unit)
B) 125A (UPS)
Supplying and fixing 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ABB/Cabtree) [D-6/7] A) 40A
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ABB/Cabtree) [ D-10 /14 ] ii) 6 way Enclosure (607716)
Supplying and fixing 240/415 V FP MCB Isolator on din rail of existing DBs and necessary connection. (Make-Legrand/L&T) [D-5/ 6] i) 63 A
Supplying and fixing 240/415 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/ABB/Cabtree) [D-6/ 7] i) 25A
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand) [ D-9 /13] i) 2+12 way Enclosure (607712)
Supplying and fixing 240/415 V DP MCB Isolator on din rail of existing DBs and necessary connection. (Make-Legrand) [D-5/ 6] i) 40A
Supplying and fixing 240/415 V SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make-Legrand) [D-6/ 7] i) i) 6A-16A
ii) SF Cabel entry box for VTPN
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand Polycab/Finolex/RR cable) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required [E-14/ 1(a)] a) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
b) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
c) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
d) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
e) 4x80/0.4 (10 sqmm) + 2x84/0.3 (4 sqmm) as ECC
f) 4x80/16 sq. mm+ 2x84/0.3 (4 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9] i) 2.5 sq mm
ii) 4 sq mm
iii) 6 sq mm
iv) 10 sq mm
v) 16 sq mm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Avg run 8 mtrs
do-do-on board 6A modular plug point
Supply & delivery of 4ft T8 22W single LED fitting complete with 1×18W LED tube on ceiling with ceiling plate down rod etc. as required. ( Philips- Cat No. TMC 501/Magik LED/ Crompton- LTT8-20 & IGP131LT8/ Wipro)
Supply & delivery of 4ft 22W twin LED fitting complete with 2×22W LED tube on ceiling with ceiling plate down rod etc. as required. ( ( Philips- Cat No. TMC 501/ Crompton- LTT8-20 & IGP132LT8/ Syska )
Fixing only fluorescent light fitting suspended 25 cm bellow theceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl.S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.[ C-2/15]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ C-2/16]
S & D of ceiling fans (make - Orient summer king/ Usha Striker) of following dimensions: 48''
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ C-3/21.(a)]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
S & F 30cm (12'') sweep A.C. exhaust fan (EPC-heavy duty) after cutting after cutting holes in the wall and making good the damages and smooth cement finsh etc. as practicble as possible and providing necy length of PVC insulated Cu wire and making connections incl. S& F louver shutter necy. nut & bolts.
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mmdia x 62 mm long) Aluminium [D-14/32.(a)] i) 30 cm Exhaust fan (12")
Supply and fixing of 3 phase Singel Timer mini control panel on wall comprising of i) 415 V AC, 4 Pole 100A Power contractor Make-L&T and Simense ii) Digital Timer Dial type analogue timer 24 hour C capacity, 230 V AC Supply, iii) 415 V, 80 A,4 POLE MCB C-type, Make-Siemense, legrand iv) 230 V AC toggle switch Single pole double through, 6 A 230 V, v) 415 V, 63 A, 3 way terminal vi) 15 A, 8 way phase & natural bar to be mount on DIN rail vii)Singel phase preventor with necessary inter connection with 1.5 (control & sq. mm cu flexible 16 sq. mm(power) wire (finolex/havels/kei) including ferrule marking & socketing with in the 16 way 4 way TPN Enclosure Box( Make- Legrand / L&T)
Supply & Fixing separate Power plug Board :- MS Box 3 mm Sheet,12''x8" with Backelite Top Cover Comprising of 4 x5/15 Amp Switc & socket with necessary interconnection (Make Anchor) on WallWith i)230 V LED indicator = 1 No ii) 20 Amp SP MCB, 10KA , C-Curve =1 No iii)with 63 Amp Nutral Bar on insulating chair car ,Earth Busbar
Supply & Fixing separate Power plug Board :- MS Box 3 mm Sheet,8''x6" with Backelite Top Cover Comprising of 1x5/15 +1x5 Amp Switc & socket with necessary interconnection (Make Anchor) on Wall with 63 Amp Nutral Bar on insulating chair car ,Earth Busbar
Supply & Fixing 240 V, 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supplying & laying of 1.1 KV. Gr. armored XLPE Al. LT cable of following rating on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting for connection from meter loop to LT main panel, from LT panel to VTPN as reqd. complete with necessary gland and terminator as per GS. Make- Ploycab/ Gloster/Finolex i) 1Cx630 sq. mm
ii) 4core X 400 sq.mm.
iii) 4core X 120 sq.mm.
iv) 4core X 95 sq.mm.
v) 4 core X 50 sq. mm.
vi) 4 core X 25 sq. mm.
vii) 1 core X 150 sq. mm.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables. [F4/7©] i) 1Cx630 sq. mm
ii) 4core X 400 sq.mm.
iii) 4core X 120 sq.mm.
iv) 4core X 95 sq.mm.
v) 4 core X 50 sq. mm.
vi) 4 core X 25 sq. mm.
vii) 4 core X 16 sq. mm.
viii) 1 core X 150 sq. mm.
Finishing of the XLPE/PVC insulated armoured cable ends by crimping method with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. [F-5/8.(b)] i) 1Cx630 sq. mm
ii) 4core X 400 sq.mm.
iii) 4core X 120 sq.mm.
iv) 4core X 95 sq.mm.
v) 4 core X 50 sq. mm.
vi) 4 core X 25 sq. mm.
vii) 4 core X 16 sq. mm.
viii) 1 core X 150 sq. mm.
S&F Out door type loop box ,canopy tupe ,air vent,dust and vermin proof rubbr gasketed,throughly painted,16 SWG CRC sheet, Bakelite back cover,DIN Chanel,415 v,4 pole,63Amp TPN MCB isolator (Make-legrands) including cabel entry & Exit hole
S&F Door limit switc (1no+1nc Type) 230v, 6 Amp
S&F 4.5' Air Curtain fan ,Metal body, 230 V , Make =Aeroteck
S&F DOL starter LT/LK MK1 wih over load Relay ,415 V ,4 pole ,12-18 AMP on angel iron frame.
S&F 4 pole onload Change Over Switch 415 V ,200 AMP on angel iron frame for UPS
S&F TPN SDSFU 415 V ,40 AMP on angel iron frame
Repair of defective Numeric make UPS at different location under R.G. Kar MCH Premises [concern agency have to be deputed experience person for repairing of UPS as per direction of EIC] a) Replace the defective UPS Module of 80 KVA and 40 KVA UPS module of 6.7 KVA rating , Make-Numeric
b) Replace the defective control card of UPS 40 KVA and 2nos 80 KVA UPS
c) Replace the defective back panel PCB of UPS
d) Replace the defective 84 Amp hour UPS battery , Make Exide
S&F 4 pole MCB ,415 V AC ,10 KA with in metalenclosure box
Supply & fixing of 250V single phase (OLP-30) 25A capacity motor starter complete on wall including its enclosure box.Make - Ultra tech after concealing the wall and mending good the damages as to G.S.
S&D of 240v , 3 pin 240v, 16 amp plug top with indicator . Make- ANCHOR
Supply & Fixing of Timer mini control panel on wall comprising of - i) 230 V AC Mini Power contactor , Coil Voltage -230 Volt AC , ii)Digital timer /Dial type analogue timer 24 Hours capacity , 230 V AC Supply. iii)230V ,25 A DP MCB , C-type , iv) 230 V ,AC toggel switch ,Single pole Double throw , 6A, 230 Volt .V)230 V ,15 Amp ,3 Way terminalvi) 15 amp ,8 way nutral bar , to be mount on DIN rail with necy. interconnection with 1.5 sq. mm cu. flexible wire(Finolex/Haveels).including Ferrule marking & Socketing With in the 12 way SPNDB MCB Enclosure Box . Make- ABB /Cabtree .
Supply & fixing of 10" x 8" x 2½ sizes of sheet steel board with 3mm. Thick bakelite cover including S&F over it the following accessories and making necessary interconnection with copper connections wire as required . Concealing in wall & mending the damages to its original finish. i) 250V 16A 5/3 pin plug socket (Anchor) - 1no. ii) 250V 16A piano key type switch (Anchor) - 1no. iii) 250V 6A 5/3 pin plug socket (Anchor) - 3nos. iv) 250V 6A 5/3 pin plug socket (Anchor) - 3nos. v) 250V Superior type Indicator (Anchor) + Fuse - 1no. vi) 250V 6way brass neutral bars inside it - 3nos.
Minor CIVIL WORK FOR errection of feeder piller box (CONNECTING DUCT Preperation) a) Excavation of soil and rmove the soil from site to out of campus
b) Cost of 125mm thick brick works with 1st Class bricks in cement morter (1:3) in ground floor . Location- Anatomy Plant Room Single brick flat soiling of pickul Jhama Bricks incl. ramming & dressing bed to proper level & filling joints with local sand .Location- Anatomy Plant Room Plaster with sand & cement morter incl. corner as directed with 1:6 cement morter .Location- Location- Anatomy Plant RoomAnatomy Plant Room
c) 4 inch Slab thick RCC Concrete as duct cover is made from cement concrete grade (1:2:3) with 10 mm MS rod Singel NET . On the angel iron rectangular frame is made of 40x40x5 mm
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
Prava Enterprise
Electromech Engineers Co-Operative Society Ltd.
GEETALI ENGINEERING SERVICES
technical_690879.pdf
PDF • 0.28 MB
techsummary_690879.pdf
PDF • 0.28 MB
finance_690879.pdf
PDF • 0.28 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_690879.pdf
PDF • 0.27 MB
AOC.pdf
PDF • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .