Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC R2 612 GOPAL NAGAR BLOCK A DHANSA ROAD NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | ₹36.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹42.8 LRejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹42.8 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹46.3 LRejected-Finance 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | ₹46.3 L | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S Anand Enterprises L2 | Truly Technos LLP L3 | Poorvi Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 conforming to CPCB IV+ Norms and alternator as per IS : 13364 of capacity 82.5 KVA at site complete with control panel having meters, sound proof canopy etc including all accessories and standard fittings and foundation as per manufactures design /recommendation and and as per the details given below and independent relay panel for automatic on mains failure:-
Note : The capacity of generator set shall be net after all derating factor as per relavent IS design. | 1 | Each Job | 16,85,000 ₹16.9 L | 13,90,000 ₹13.9 L | 14,99,999 ₹15.0 L |
| 1.01(A) Alternator : Standard design alternator rated at 82.5 KVA (66 KW) net output at site after considering all derating factors, site conditions and at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B) DIESEL ENGINE : Developing a net directed output of 105 BHP or higher nearest available @1500 RPM suitably matched with alternator to give a net directed output of 82.5 KVA vertical diesel engine of suitable capacity ,water cooled,closed circuit as per BS-649 or IS-1002 direct injuction type turbo charged, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for 01 hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following Specifications :- (a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions . (b)Cooling system (i) Radiator with fan belts &guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . (c)GOVERNER : Electronic Governer. | ||||||
| 1.02(d) ELECTRIC STARTING SYSTEM : Electric Self starter , 12/24 volts DC with suitable rating battery as per manufacture's recommendations . (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES: AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (h) EXHAUST SYSTEM : Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size all as directed. (j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturer's design. (C) . ACOUSTIC ENCLOSURE : All as per CPCB IV+norms and OEM of DG Set's design. Make of acoustic enclosure | ||||||
| 1.03(D) AMF Panel :Design, supply, install, test & commissioning of factory made AMF Panel board suitable for carrying current up to 110% of full load of 82.5 KVA DG set having IP 54 protection, Out door, free standing, floor mounted, dust and vermin proof, cubical type, made out of CRCA sheet 3.15 mm thick and shall be painted with epoxy powder paint by means of electro static gun after rigorous pretreatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces, totally enclosed with front and rear opening, hinged doors, locking arrangements. [ Panel - CPRI Approved or OEM of manufacturere of DG set) Control panel shall be provided with suitable internal wiring with copper cable of suitable size, main contactors with 415 Volt coil, switch gears (4 pole MCCB in incoming main supply & DG set supply and out going with Ics = 100% Icu) , copper bus bars with colour coded heat shrinkable PVC sleeves with suitable inter connecting copper wire DG supply and main supply / copper strips, control wires, relays, timers, bakelite control fuses, measuring devices such as Voltmeter, Ammeters both for AC & DC, mulitifunction meter for displaying various parameters of DG sets all as required & current transformer of suitable ratio, Selector switches, HRC fuses, earth bus and bolts etc. The panel shall be with standard functional system with necessary accessories for automatic start of DG set on main supply failure and stop when mains restore after necessary cooling. The control panel shall be provided with standard over load, earth fault relay, indicating lamps and manual control switches / push button switches for DG Set ON / OFF, DG Contactor ON / OFF, Mains Contactor ON / OFF, RESET, ACK, TEST, TRIP with indicating lamps, including battery charging system with rectifier bridge, transformer of suitable size and capacity to charge batteries trickle / boost and unbalanced voltage tripping system all as specified including taking out of old panel complete all as specified and as directed by the Engineer - in - Charge. Note : (i)The Out door AMF panel shall be with by pass arrengements with on load chageover switches of same rating as per MCCB. (ii) The contractor to submit the drawing of panel for approval of accepting authority. | ||||||
| 2.00 | Supply, install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 conforming to CPCB IV+ Norms and alternator as per IS : 13364 of capacity 30 KVA at site complete with control panel having meters, sound proof canopy etc including all accessories and standard fittings and foundation as per manufactures design /recommendation and and as per the details given below and independent relay panel for automatic on mains failure:-
Note : The capacity of generator set shall be net after all derating factor as per relavent IS design. | 1 | Each Job | 8,85,000 ₹8.8 L | 6,95,000 ₹7.0 L | 7,99,999 ₹8.0 L |
| 2.01(A) Alternator : Standard design alternator rated at 30 KVA (24 KW) net output at site after considering all derating factors, site conditions and at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B) DIESEL ENGINE : Developing a net directed output of 42BHP or higher nearest available @1500 RPM suitably matched with alternator to give a net directed output of 30 KVA vertical diesel engine of suitable capacity ,water cooled,closed circuit as per BS-649 or IS-1002 direct injuction type turbo charged, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for 01 hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following Specifications :- (a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions . (b)Cooling system (i) Radiator with fan belts &guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . (c)GOVERNER : Electronic Governer. | ||||||
| 2.02(d) ELECTRIC STARTING SYSTEM : Electric Self starter , 12/24 volts DC with suitable rating battery as per manufacture's recommendations . (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES: AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (h) EXHAUST SYSTEM : Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size all as directed. (j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturer's design. (C) . ACOUSTIC ENCLOSURE : All as per CPCB IV+norms and OEM of DG Set's design. Make of acoustic enclosure | ||||||
| 2.03(D) AMF Panel :Design, supply, install, test & commissioning of factory made AMF Panel board suitable for carrying current up to 110% of full load of 30 KVA DG set having IP 54 protection, Out door, free standing, floor mounted, dust and vermin proof, cubical type, made out of CRCA sheet 3.15 mm thick and shall be painted with epoxy powder paint by means of electro static gun after rigorous pretreatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces, totally enclosed with front and rear opening, hinged doors, locking arrangements. [ Panel - CPRI Approved or OEM of manufacturere of DG set) Control panel shall be provided with suitable internal wiring with copper cable of suitable size, main contactors with 415 Volt coil, switch gears (4 pole MCCB in incoming main supply & DG set supply and out going with Ics = 100% Icu) , copper bus bars with colour coded heat shrinkable PVC sleeves with suitable inter connecting copper wire DG supply and main supply / copper strips, control wires, relays, timers, bakelite control fuses, measuring devices such as Voltmeter, Ammeters both for AC & DC, mulitifunction meter for displaying various parameters of DG sets all as required & current transformer of suitable ratio, Selector switches, HRC fuses, earth bus and bolts etc. The panel shall be with standard functional system with necessary accessories for automatic start of DG set on main supply failure and stop when mains restore after necessary cooling. The control panel shall be provided with standard over load, earth fault relay, indicating lamps and manual control switches / push button switches for DG Set ON / OFF, DG Contactor ON / OFF, Mains Contactor ON / OFF, RESET, ACK, TEST, TRIP with indicating lamps, including battery charging system with rectifier bridge, transformer of suitable size and capacity to charge batteries trickle / boost and unbalanced voltage tripping system all as specified including taking out of old panel complete all as specified and as directed by the Engineer - in - Charge. Note : (i)The Out door AMF panel shall be with by pass arrengements with on load chageover switches of same rating as per MCCB. (ii) The contractor to submit the drawing of panel for approval of accepting authority. | ||||||
| 3.00 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge. | 351.54 | Cum | 120 ₹42,184.80 | 80 ₹28,123.20 | 59 ₹20,740.86 |
| 4.00 | Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge | 194 | Cum | 40 ₹7,759.92 | 50 ₹9,699.90 | 9.99 ₹1,938.04 |
Updated dates
Tender Value
₹43.7 L
EMD Value
₹87,340
Closing Date
12 Jan 2026, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_744804_1
GE/SP/TOKEN-64/2025-26
Open Tender
Electrical and Maintenance Works
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹87,340
Yes
18 Mar 2026
16 Dec 2025
15 Jan 2026
16 Dec 2025
12 Jan 2026
31 Dec 2025
Amount
Supply, install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 conforming to CPCB IV+ Norms and alternator as per IS : 13364 of capacity 82.5 KVA at site complete with control panel having meters, sound proof canopy etc including all accessories and standard fittings and foundation as per manufactures design /recommendation and and as per the details given below and independent relay panel for automatic on mains failure:- Note : The capacity of generator set shall be net after all derating factor as per relavent IS design.
(A) Alternator : Standard design alternator rated at 82.5 KVA (66 KW) net output at site after considering all derating factors, site conditions and at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B) DIESEL ENGINE : Developing a net directed output of 105 BHP or higher nearest available @1500 RPM suitably matched with alternator to give a net directed output of 82.5 KVA vertical diesel engine of suitable capacity ,water cooled,closed circuit as per BS-649 or IS-1002 direct injuction type turbo charged, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for 01 hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following Specifications :- (a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions . (b)Cooling system (i) Radiator with fan belts &guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . (c)GOVERNER : Electronic Governer.
(d) ELECTRIC STARTING SYSTEM : Electric Self starter , 12/24 volts DC with suitable rating battery as per manufacture's recommendations . (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES: AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (h) EXHAUST SYSTEM : Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size all as directed. (j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturer's design. (C) . ACOUSTIC ENCLOSURE : All as per CPCB IV+norms and OEM of DG Set's design. Make of acoustic enclosure
Supply, install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 conforming to CPCB IV+ Norms and alternator as per IS : 13364 of capacity 30 KVA at site complete with control panel having meters, sound proof canopy etc including all accessories and standard fittings and foundation as per manufactures design /recommendation and and as per the details given below and independent relay panel for automatic on mains failure:- Note : The capacity of generator set shall be net after all derating factor as per relavent IS design.
(A) Alternator : Standard design alternator rated at 30 KVA (24 KW) net output at site after considering all derating factors, site conditions and at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B) DIESEL ENGINE : Developing a net directed output of 42BHP or higher nearest available @1500 RPM suitably matched with alternator to give a net directed output of 30 KVA vertical diesel engine of suitable capacity ,water cooled,closed circuit as per BS-649 or IS-1002 direct injuction type turbo charged, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for 01 hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following Specifications :- (a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions . (b)Cooling system (i) Radiator with fan belts &guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . (c)GOVERNER : Electronic Governer.
(d) ELECTRIC STARTING SYSTEM : Electric Self starter , 12/24 volts DC with suitable rating battery as per manufacture's recommendations . (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES: AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (h) EXHAUST SYSTEM : Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size all as directed. (j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturer's design. (C) . ACOUSTIC ENCLOSURE : All as per CPCB IV+norms and OEM of DG Set's design. Make of acoustic enclosure
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm.
Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid in in trenches as protection to cable all as specified and directed by Engineer-in-charge
Supply, laying and testing of XLPE LT 1100 Volt Grade, armourd under ground cable size of 6 Sqmm 4 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and directed.
All as per item no 8.00 but for cable size 10 sqmm 4 core
All as per item no 8.00 but for cable size 16 sqmm 4 core
All as per item no 8.00 but for cable size 25 sqmm 4 core
All as per item no 8.00 but for cable size 50 sqmm 3.5 core
All as per item no 8.00 but for cable size 70 sqmm 3.5 core
All as per item no 8.00 but for cable size 120 sqmm 3.5 core
All as per item no 8.00 but for cable size 185 sqmm 3.5 core
Supply and fixing of FRP Pole Junction box three phase type with one no MCB SP 10 Amp complete all as specified and directed.
Supply and fixing PVC insulated FRLS 1.5 sqmm 3 core,1100 volt round copper wire passing through steel tubular pole and connecting with light and juction box with necessary lugs complete all as specified and directed .
S& F 3 phase Automatic transfer switch suitable for 20 amp complete all as specified and directed.
M/S Anand Enterprises (BID ID -3521880)
Truly Technos LLP (BID ID -3516307)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_833975.xls
BOQ • 0.30 MB
Tender64.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid