Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC AT MAIN ROAD KATHARA PO KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | ₹3.0 L Quoted ₹2.5 L | L1 | Accepted-AOC ACCEPTED AS PER NIT |
| 2 | L2₹2.6 LRejected-Finance AT WASHERY ROAD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | ₹2.6 L | L2 | Rejected-Finance REJECTED AS PER NIT |
| 3 | Rejected-Technical AT JHIRKEY PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | 829116 | - | - | Rejected-Technical Technically Rejected, as per NIT |
| Sl No | Description | Qty | Unit | M/S ATRACON ELECTRICALS L1 | M/S SHYAM ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | A. 6.6 KV, VCB switch, 1250 Amps, make-Andrew Yule, SI. No.1725 installed at 03 no. quarry
(put zero against this row in rate column) | 1 | Job | - | - |
| 1.01 | Supplying and fixing Trip coil | 1 | No. | 2,865 ₹2,865 | 9,800 ₹9,800 |
| 1.02 | Supplying and fixing Close Coil | 1 | No. | 2,865 ₹2,865 | 9,800 ₹9,800 |
| 1.03 | Supplying and fixing Limit switch | 1 | No. | 1,763 ₹1,763 | 4,500 ₹4,500 |
| 1.04 | Supplying and fixing Auxiliary switch 110 V | 1 | No. | 4,160 ₹4,160 | 18,900 ₹18,900 |
| 1.05 | Supplying and fixing Brass stud with bushing, washer, clamp etc. as required (1" x 23.5") | 4 | set | 12,000 ₹48,000 | 4,500 ₹18,000 |
| 1.06 | Supplying and fixing Heavy duty resin cast current transformer 400-200A/5-5A | 1 | Set | 27,963 ₹27,963 | 25,200 ₹25,200 |
| 1.07 | Supplying and fixing of P.T. fuse 6.6KV/1A | 1 | Set | 3,482 ₹3,482 | 1,200 ₹1,200 |
| 1.08 | Supplying and fixing Core Balance Transformer moulded type square | 1 | set | 20,250 ₹20,250 | 35,000 ₹35,000 |
| 1.09 | Supplying and fixing CONTROL SWITCH (TNC), 32A 110V | 1 | set | 3,717 ₹3,717 | 4,500 ₹4,500 |
Tender Value
Refer Docs
EMD Value
₹3,600
Closing Date
19 Mar 2026, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
P.E. (EnM), Office of the PO, Kathara Colliery
repair of (A) one no. 6.6 KV, VCB switch, 400 Amps, make-Meditron, SI. No.7741 installed at 03 no. quarry and (B) one no. 3.3 KV, 400A.VCB Switch make WNP installed at 4 no. pani tanki for power supply to colonies under Kathara Colliery.
2026_CCL_356115_1
KTC/PE/EnM/25-26/121, dated-09.03.2026
Open Tender
Electrical and Maintenance Works
15 days
P.E. (EnM), Office of the PO, Kathara Colliery
As per NIT
5 documents required · 5 mandatory
₹3,600
28 Mar 2026
9 Mar 2026
20 Mar 2026
10 Mar 2026
19 Mar 2026
10 Mar 2026
10 Mar 2026 - 15 Mar 2026
A. 6.6 KV, VCB switch, 1250 Amps, make-Andrew Yule, SI. No.1725 installed at 03 no. quarry (put zero against this row in rate column)
Supplying and fixing Trip coil
Supplying and fixing Close Coil
Supplying and fixing Limit switch
Supplying and fixing Auxiliary switch 110 V
Supplying and fixing Brass stud with bushing, washer, clamp etc. as required (1" x 23.5")
Supplying and fixing Heavy duty resin cast current transformer 400-200A/5-5A
Supplying and fixing of P.T. fuse 6.6KV/1A
Supplying and fixing Core Balance Transformer moulded type square
Supplying and fixing CONTROL SWITCH (TNC), 32A 110V
Supplying and fixing Rectifier Unit 110V DC
Supplying and fixing Wiring with ferruls & Lugs
Supplying and fixing of copper strip, including holes of the required size along with a nut and washer
B. 3.3 KV, VCB switch, 400 Amps, make-WNP installed at 4 no. pani tanki (put zero against this row in rate column)
Supplying and fixing Trip coil
Supplying and fixing Close Coil
Supplying and fixing Limit switch
Supplying and fixing Auxiliary switch 110 V
Supplying and fixing Brass stud with bushing, washer, clamp etc. as required (1" x 23.5")
Supplying and fixing Heavy duty resin cast current transformer 400-200A/5-5A
Supplying and fixing of P.T. fuse 3.3KV/1A
Supplying and fixing Core Balance Transformer moulded type square
Supplying and fixing CONTROL SWITCH (TNC), 32A 110V
Supplying and fixing Rectifier Unit 110V DC
Supplying and fixing Wiring with ferruls & Lugs
Supplying and fixing of copper strip, including holes of the required size along with a nut and washer
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.02 MB
BOQ_368969.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid