CWE
HQ CWE Rajouri PIN-900129 C/o 56 APO
REPAIR /REPLACEMENT OF UNSV HT POLES, OH CONDUCTOR AND CONNECTED WORKS AT NARIAN UNDER GE 862 EWS
2022_MES_505148_1
CANO-CWE/RAJ-63/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
Narian AOR of GE 862 EWS
Class E category b(ii)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹32,000
Yes
1 Apr 2022
1 Feb 2022
9 Mar 2022
1 Feb 2022
2 Mar 2022
15 Feb 2022
60 days
Amount
Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse of serviceable ACSR conductor in the work & removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of GI earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and as directed.
Dismantling of old, unserviceable HT (PCC) concrete pole of any size with necessary demolition of concrete, complete all as specified and as directed.
Takig down old unserviceable HT cable any size from any position complete all as specified and directed.
HT XLPE insulated , screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor ,11000 volts grade cross sectional area 120 Sq mm 3 core complete all as specified and directed.
Taking down old unserviceable HT GOD any type and size complete all as specified and directed.
Air break gang operated isolator triple pole mechanically operated from ground mounted on insulators and steel frame including all fixing arrangement on HT pole, connection with ACSR, aluminium lugs, meggering & testing for current rating upto 200 amp 11000 Volts all as specified and directed.
Taking down old unserviceable GI pipe any size complete all as specified and directed.
80mm GI pipe light grade laid in trenches under road/foot path or fixed on pole with necessary clamps with nut, bolts etc complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation of stay/poles, laying of cable etc.and getting out in any type of soil complete all as specified and as directed.
Description all as per item No. 10 above, but for each additional 1.5 mtr or part thereof in depth beyond the first 1.5 mtr for foundation of poles, complete all as specified and as directed.
Removing excavated material(soils) n.exc 50 m and depositing where directed at a level n. exc 1.5 mtr above the starting point, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm, complete all as specified & directed.
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- (i) Dry fine sand of best available quality shall be used. (b) Punned thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for foundation around poles/stay, including necessary form work, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete and removing the same from site complete all as specified & as directed.
Steel tubular poles, swaged type, 410 SP-55, 11m long with 300x300x6mm thick MS base plate continuously welded to pole & MS sheet 2mm thick finial tapper plug welded at top, bolts, nuts and screws all as specified including two coats of black bituminous paint internally throughout and externally for embedded portion and two coats of aluminium paint over a coat of red oxide primer on exposed surfaces including painting up to 1.5 mtr height from ground level or above coping with two coats of synthetic enamel paint in 30cm strip, alternate balck & yellow starting with black at ground level, complete all as specified and directed. (Note:- Excavation and earth work and PCC shall be measured & paid separately)
Stay assembly for electric pole complete with accessories as shown in electrical plate No. 1 of SSR Pt-I and drg using stay rod of 20mm dia fixed including loop type isulator, stay bow complete all as specified. Note : Excavation, earthwork and PCC shall be measured and paid separately.
ACSR condutor of any size including stretching, fixing and binding to insulator on OH over head line including necessary aluminium binding wire or tape, jumpering, maintaing proper sag as per IE Rule including cutting of tree branches around the ACSR with in area of 2 mtr dia all as specified and as directed.
Description all as per item No. 22 above, but restraining of old serviceable ACSR conductor of any size including maintaining proper span sag complete all as specified and directed by Engr-in-Charge.
Galvanised steel wire 3.15/4 mm dia as in contenious earth wire/guard or cradle wire made to shape hexagonal/rectangular fixed on poles for LT feeder including binding the same with new GI binding wire not less than 2 mm dia complete all as specified & as directed.
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting a side serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
Cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT/LTover head line and painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed by Engr-in-Charge.
Fixing only old serviceable cross-arms obtained from ser itm No 25 ave with providing new bolts, nuts and washers as reqd including painting with one coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting a side serviceable insulators for reuse in the work & removing unserviceable insulator from site, complete all as specified & as directed.
Pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for 11000 volts grade, complete all as specified & as directed.
Description all as per item No. 29 above but fixing only old serviceable pin type insulator as obtained from item No 28 here-in-before after through visual checking and testing with HT megger all as directed by Engr-in-Charge.
Description all as per item No. 29 here-in-before, but for 33000 Volt grade, complete all as specified & directed by Engr-in-Charge.
Disc type insulator, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brown or green "two in series" assembly for tension with tension clamps for conductors working pressure 11000 Volts, complete all as specified & as directed.
Description all as per item No. 32 above but fixing only old serviceable single disc assembly as obtained from item No 28 here-in-before after thorough visual checking and testing with HT megger all as directed by Engr-in-Charge.
Description all as per item No. 32 here-in-before, but for 33000 Volt grade, complete all as specified & as directed.
40mm GI pipe light grade laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified & as directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and CI cover and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, complete all as specified and directed.
Description all as per ser item No 36 above but using GI earth lead strip of 32 x 6 mm as earth lead with and including 40mm dia GI light grade protection pipe, complete all as specified and directed.
Painting to old painted HT poles, 11m high with cross arms, bracing and clamps with two coats of synthetic enamelled paint including scrapping the old paint carefully to make smoothen complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30cm height, complete all as specified and directed.
Cable jointing kit for 11 KV grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
Cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed.
Cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm, complete all as specified and directed.
Lightening arrester expulsion type complete with all fittings transmission class, discharge capacity 65 kilo Amps suitable for 11000 Volts complete all as directed by Engr in Charge.
Lightening arrester expulsion type complete with all fittings transmission class , discharge capacity 65 kilo Amps suitable for 33000 Volts complete all as directed by Engr in Charge.
Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint for XLPE (screened)of size 50 to 95 sqmm 3 core cable, complete all as specified and directed.
Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint for XLPE (screened)of size 120 to 185 sqmm 3 core, complete all as specified and directed.
Testing & calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system through authorised dealer for smooth functioning and VCB should be tripped at any type of fault developed in feeders complete all as specified and directed by Engr in Charge. Note :- (a) Contractor will submit primary and secondary test record at the time of calibration of HT VCB duly signed by the technical staff of authorised dealers. (b) Replacemnt of unservicable items mentioned under item No-47 to 49 required to be replaced will be measured and paid separatly as supply only under relevent items & other unsv items if any are included in rates to be quoted by the contractor.
Supply only 1250 Amp Voacume interupter Make - Electric feild / ABB/ CG
Supply only Amp Meter 96 x 96 mm with MS plate with accuracy 1.00 with CT s Make - Electric feild / ABB/ CG / Schneider
Supply only Volt Meter 96 x 96 mm with MS plate with accuracy 1.00 with CT s Make - Electric feild / ABB/ CG / Schneider
Replacement of stay wire stranded 7/3.15mm including stay clamp and fixing arrangement complete all as specified
Jiwan Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .