| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.8 L+₹5.8 L (20.8%)Rejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹34.5 L+₹6.5 L (23.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.9 L+₹8.0 L (28.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | Rejected-Technical 0 | - | Rejected-Technical Rejected |
Tender Value
₹27.6 L
EMD Value
₹55,200
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
PROVISION OF CERTAIN SANCTION AND MINOR WORKS UNDER GE (AF) BAMRAULI
2021_MES_464018_2
8671
Open Tender
Civil Works
Works
120 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹55,200
Yes
1 Sept 2021
16 Aug 2021
24 Aug 2021
16 Aug 2021
23 Aug 2021
18 Aug 2021
60 days
Amount
Taking down Tower AC 3.0 Ton from its original postion and refix the same to another location after servicing and charging of gas (M410a/R134a/R-22) by testing the leakage in system by filling of Ntrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work , cleaning and flushing out the complete system leak proof , vacuuming the system and as existing and testing etc complete all as specified and directed
Dismantling and taking down and depositing to MES Store yard of old unserviceable split type AC of 1.5 ton capacity
Supply & fixing testing and commissioning Casette type AC having energy efficient fixed speed Compressor, Copper Condenser & Evaporator Coil. Factory Charged Eco Friendly Refrigerant (Environment Friendly). 3.0 TR Nominal Capacity (3 Phase Operation). Make :CARRIER/VOLTAS/BLUE STAR
Supply & fixing of Refrigerant Copper Piping of follwing sizes and all as specified and directed.
(a) Dia size of 6/8 ''
(b) Dia size of 3/8 ''
Supply &fixing of Insulation Copper Piping for following sizes and all as specified and directed.
(a) Dia size of 6/8 ''
(b) Dia size of 3/8 ''
Supply fabrication and Fixing of MS angle, straight channel, U channel all as specified and directed.
Supply and fixing of medium class insulated Hard PVC Drain Water pipe with 6mm nitile rubber insulation with fittings for 25 mm dia all as specified and directed.
Supply and laying of contral cum transmission wiring between ODU & IDU of copper (4 core x 2.5 sqmm) all as specified and directed.
S & F sheet metal enclosure of suitable size with CRCA sheet wall mounted bus bar panel comprising 125 Amp 4 pole 25KA MCCB as incomer,04 No copper bus bar 150 Amp duly mounted on epoxy base insulater with including locking arrangement all as specified and directed.
Supply, laying, jointing & testing of underground LT cables XLPE insulated, PVC sheathed, aluminium conductors, multistranded, armoured heavy duty 1100 Volt grade cross sectional area 25 Sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs including taking out Note :- (i) Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. (ii)Fastner,clip etc minor spare parts including in quoted rate all as specified and directed. Make : RR Kable/Finolex/Gloster
Excavation in trenches/Pits in any type of soil(soft soil), n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete, all as specified & directed .
Returning filling in with the earth obtained from Item here-in-before including spreading, leveling and well ramming in layers n.exc. 25cm thick complete all as specified & directed.
Supply and spreading clean and dry sand (unwashed) in trenches around the cable for cushioning all as specified & directed.
Removal of surplus excavated material to a distance n.exc. 50 Mtr and depositing where directed at a level n.exc. 1.5 Mtr above starting point complete all as specified & directed
Supply and laying sub class 'B' bricks (Old Size) laid flat in trenches as cable covers all as specified and directed
Supply and laying Pipes galvanized, “Light grade class”, supplied And laid complete including fittings 40 mm dia all as specified and directed.
S&F sheet metal enclousre for DB's for triple pole and neutral 4 way double door type 415 Volt ,50 Hz complete all as specified and directed by Engineer –in-Charge
S& F MCB TP & N 40 Amps ,415 volts 50 Hz as specified and directed
M&L for Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
S&F Sub main wiring with four run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete.
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete.
S&F sheet metal single pole and neutral enclosure with two pin and earth plug and socket capacity 20-32 Amps complete with one No SP MCB capacity 20-32 Amps complete all as specified and directed by Engineer –in-Charge.
M& L for boring holes (manually) under road ,hard standing,without damaging surface for 50 mm dia GI pipe etc complete all as specified and directed. Note : Depth of hole shall be metre below the top surface of road/hard standing.
Supply installation commissioning and testing hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rated, invertor type and capacity 2.0 ton including breaking necessary hole in wall any type for fixing indoor and outdoor unit and making good disturbed surfaces with cement mortar and paint to match existing surface, all as required including necessary connections complete all as specified and directed . Make : Carrier/Voltas/Blue Star.
Supply installation commissioning and testing hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rated, invertor type and capacity 1.5 ton including breaking necessary hole in wall any type for fixing indoor and outdoor unit and making good disturbed surfaces with cement mortar and paint to match existing surface, all as required including necessary connections complete all as specified and directed . Make : Carrier/Voltas/Blue Star.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled outdoor type,Built-In Thermal Overload Protection,Low & High Voltage cut-off Protection & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. Make : V GUARD (Model No. VND500)/ BLUEBIRD (Model No. BA514A) or equivalant
S&F copper tubing of dia 1/2" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed by Engineer-in-Charge
S&F copper tubing of dia 1/4" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed by Engineer-in-Charge
S&F low density polyether pipe (LDPE) of pressure rating 6Kg/cm2 drain pipes of size 40 mm from indoor unit to exist point as per design including accessories clamps fastners complete all as specified and as directed by Engineer –in-Charge
M&L for outdoor unit stand for wall mounting type or floor mounted complete factory made as recommended for make Airconditioner and approved by Engr-in-charge.
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete.
S&F MCB, SP, 32 Amp rating, 230 volt, 10 KA, 'C' series suitable for fixing in DBs as specified and directed.
Supplying and fixing of 90W LED street light fitting with luminare made up of pressure die cast aluminium housing with toughned glass and individual LED lenses complete making connection with 1.5 Sqmm, 3 core, copper round wire. (i) The driver should be potted ant vibration type, IP66 should be sustain 440 volt for 2-4 hrs (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour Rendering Index of fixture shall be greater then 70 (iv) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt complete all as specified and directed.
S&F LED Flood light fitting 250 watt, with surge protection 4KV inbuilt in driver and minimum 10 KV separate, IP66 having Pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses complete making connection with 1.5 Sqmm, 3 core, copper round wire and suitable for mounted on angle iron frame. (i) The driver should be potted ant vibration type, IP66 should be sustain 440 volt for 2-4 hrs (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour Rendering Index of fixture shall be greater then 70 (iv) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt complete all as specified and directed.
S&F steel tubular swaged poles complete with MS base plate of size 300 mm x300mm x 6 mm thick ,final taper plug,bolts,nuts and screws as specified type 410 SP-31 (09 meters long) Including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type (C-2) (using 40 mm graded stone aggregate ) in foundations of size 1.20 m X 0.60 m X 1.65 m below GL, PCC 1:2:4 type (B- 1 )(using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and and providing 3 Nos of 30cm wide circular bands with Aluminium & blue paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete( M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents.)complete inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
S&F perimeter lights bracket complete with 1.2m long GI pipe 40 mm dia medium grade, one no 60 degree bend, MS clamp and nuts bolts complete all as specified and directed by Engineer-in- charge.
M&L for GI tubing 50 mm dia light grade with all necessary fittings laid in trenches flxed to walls, poles, under road/floor etc for cable protection complete all as specified and directed.
S&F in replacement LED Flood light fitting 80 watt, with surge protection 4KV inbuilt in driver and minimum 10 KV separate, IP66 having Pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for mounted on angle iron frame. (i) The driver should be potted ant vibration type, IP66 should be sustain 440 volt for 2-4 hrs (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour Rendering Index of fixture shall be greater then 70 (iv) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt complete all as specified and directed.
S&F in replacement LED Flood light fitting 150 watt, with surge protection 4KV inbuilt in driver and minimum 10 KV separate, IP66 having Pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for mounted on angle iron frame. (i) The driver should be potted ant vibration type, IP66 should be sustain 440 volt for 2-4 hrs (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour Rendering Index of fixture shall be greater then 70 (iv) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt complete all as specified and directed.
Supply and fix junction box [FRP] of size 250x200x100mm complete with 100 Amp AL bus bar, 4 way, fixed on SMC insulator alongwith 01 No MCB SP 06 amps capacity with necessary fixing arrangements by providing MS clamps 2 nos made out of MS flat 25 x 5mm including nut bolts etc complete.
Supply & Laying PVC insulated, FR PVC Round sheathed, heavy duty electric cable with Copper conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 Core.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 Core all as specified and directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
bharat construction
M/s Techno India and Company
M/s Hanspal Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .