Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.2 LAccepted-AOC | 1 | Accepted-AOC 1st Lowest | |
| 2 | 2₹37.5 L+₹2.9 L (8.28%)Rejected-Finance | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹37.8 L+₹3.2 L (9.09%)Rejected-Finance | 3 | Rejected-Finance Other than lowest | |
| 4 | 4₹38.7 L+₹4.1 L (11.8%)Rejected-Finance | 4 | Rejected-Finance Other than lowest | |
| 5 | 5₹47.4 L+₹12.7 L (36.7%)Rejected-Finance | 5 | Rejected-Finance Other than lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
9 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mhow
HQ CWE Mhow cantt Mhow-453441
REPAIR MAINTENANCE OF HT DISTRIBUTION SYSTEM AND OTHER ALLIED WORKS UNDER GE MCTE MHOW
2022_MES_565114_2
CWE(MHOW)/16(T)OF2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE Mhow
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (MCTE) Mhow
₹84,000
9 Mar 2023
19 Jan 2023
11 Feb 2023
19 Jan 2023
9 Feb 2023
25 Jan 2023
Amount
Supply and fix cable jointing kit for 11 KV grade (E) cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm all as directed.
Ditto all as per item No 01 above but for cable 120 to 185 sqmm.
Ditto all as per item No 01 above but for cable 240 to 300 sqmm.
Supply and fix cable jointing kit for 11 KV grade (E) cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm all as directed.
Ditto all as per item No 04 above but for cable 120 to 185 sqmm.
Ditto all as per item No 04 above but for cable 240 to 300 sqmm.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core 50 to 95 sqmm XLPE armoured aluminium conductor all as directed.
Ditto all as per item No 07 above but for cable 120 to 185 sqmm.
Ditto all as per item No 07 above but for cable 240 to 300 sqmm.
Supply & fix in replacement of Avana meter make 3 OC + 1 EF relay fixed type at 33 KV control panel all as directed.
Taking out defective/wornout parts from RMU 3 way 11 KV complete repairing work including unmounting of gas chamber, checking of interrupter and replacement of required spares, (Opening of gas chamber and refilling of SF 6 gas is carried out in factory only) and testing for smooth operation all as specified and as directed . NOTE: SF 6 gas, lubrication, cleaning agent, coating of insulation will be included in this scope.
Taking out defective/wornout parts from RMU 5 way 11 KV complete repairing work including unmounting of gas chamber, checking of interrupter and replacement of required spares, (Opening of gas chamber and refilling of SF 6 gas is carried out in factory only) and testing for smooth operation all as specified and as directed . NOTE: SF 6 gas, lubrication, cleaning agent, coating of insulation will be included in this scope.
M&L for providing under ground boring using mechanical pneumatic drilling equipment / manually for passing electric cables through by providing HDPE pipe of 100mm dia heavy quality, pressure rating 6 kg/cm2 under the existing bituminous/WBM road/PCC hard standings, depth range not more than 1.5mtr deep and making good the distrubed surfaces is to match with its existing specifications all as specified and directed. Note : Any damage to the existing cables/water pipes/structures shall be made good by the contractor at his own expense.
S&F GI tubing, light grade, ISI marked 100 mm bore pipe laid in trenches/duct or in road crossing or fixed to wall/poles for protection of cable incl taking out old pipe of any grade complete all as specified and directed.
Supply and fixing cable route indicator, made of MS sheet of size 200 mm x 150 mm x 3 mm thick, spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2( using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint showing size of cable LT complete all as specified & directed .
M&L for detection/ determination of HT cable fault by using high pot cable fault detecting machine to determine exact location of fault including necessary megger testing etc complete. (Note: Cost of T&P transportation, testing kit etc deemed to be included in unit quoted rate.)
Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep in hard dense soil for cables, stay etc and getting out complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned/consolidated thickness complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type-1, flat, size 300mm x 180mm x 40mm, ISI marked, laid flat across the cable length all as per specification and all as directed. (Make: Mahtab tiles / Alankar Tiles/Pearlers Industries/SIND Mozaic Gujrat/JJ Concrete Lucknow).
Taking down carefully old rusted / damaged switch air break, gang operated any type and size complete.
Supply,installing in repairs, connecting and commissioning switch air break gang operated triple pole for current rating 200 Amp at 11 KV, out door type , mechanically operated, mounted on insulators with 9 insulator and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe medium grade from ground level, with locking arrangements, complete all as specified.
Supply and install in repairs HT 33KV outdoor type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulator and with earth switch upto 200/400 Amps, with suitable GI pipe pipe medium grade required for operation, all as specified and directed.
Supply & laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored earth, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sqmm complete, including taking down existing cable, all as specified.
Ditto all as per item No 25 above but for cable 120 sqmm.
Ditto all as per item No 25 above but for cable 185 sqmm.
Sppply & Laying in repairs PVC insulated, unarmoured, electric copper cable of size 25 sqmm 1 core with multi stranded copper conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes & making necessary connection complete all as specified and directed.
Sppply & Laying in repairs PVC insulated, unarmoured, electric copper cable of size 10 sqmm 1 core with multi stranded copper conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes & making necessary connection complete all as specified and directed.
Dehydration of HV/EHV grade transformer oil minimum three cycles to achieve di electric strength not less than 40 KV for 1 minute with 2.5mm Gap as per IS - 335 - 1983 for EHV grade including topping up with new transformer oil all as directed. Note :- (i) Centrifuging Machine with all T&P & testing machine of oil, required for dehydration shall be arranged by contractor. (ii) Oil required for topping up the transformer will be measured & paid separately.
Supply and filling (topping up) of transformer oil EHV as per IS 335 of 1983 Part II after dehydration & testing complete all as specified and directed. (Make : Savita / power Oil)
Material and labour for disconnecting electrical connections of transformer of 11 KV / 433 V of any make & any type, capacity upto 100 KVA loading the transformer on heavy vehicle (open chassis) type from existing platform/four pole structure, by heavy crane long boom type suitable for shifting and loading transformer and transporting of transformer for repair at civil workshop at Indore city from MCTE area Mhow including unloading of transformer from vehicle at workshop & opening up transformer by unscrewing all nuts/bolts and washers of top cover duly draining out complete transformer oil and kept aside for re-use. Disconnecting of all HT/LT wiring tap changer, complete LT/HT bushing, air breather etc and kept aside for re-use the serviceable parts and removal of unserviceable parts and taking out complete core assembly of transformer with help of chain pully to carry out the following works:-
Deslurring of transformer tank by taking out the complete deposited transformer oil sludge and cleaning thoroughly the transformer tank by washing & wiping out all dirt/rust accomolated including making preparation of old painted internal/external surfaces of transformer. Painting the internal surfaces of transformer with two coats of high grade anticorrosive varnishing paint over a coat of red oxide primer. Painting to external surfaces of transformer with two coats of Ist grade synthetic enamelled paint over a coat of red oxde primer, all as shown and directed by Engr-in-charge.
Cleaning the transformer core assembly using electric blower and making the core free from sludge, dirt and any other foreign materials from its surfaces including provision of high grade insulation varnish and raising insulation of the core through heat chamber and raising of IR valve /LV-E > 500 Mega ohms HV-E >1000 Mega ohms.
Assembling the transformer complete including supply of complete set including replacement of defective accessories such as oil seal , gasket , LT/HT bushing, stud, air breather, tap changer, including making necessary LT/HT wiring as dismantled( New spares as required will be measured & paid separately under relevant items, rate of oil seal & gasket will be deemed included in the quoted rate ). Powering of dehydration/filtered transformer oil (dehydration charges will be measured and paid separately) as obtained during dismantling and top up balance quantum with new transformer oil as required (New transformer oil will be measured & paid under relevant item) after successfully repairing the transformer re-loading the same & place to its original location and installation complete including making LT/HT side cable connection, earth connection and testing complete.
Ditto all as per item No 32 above but for transformer of 11 KV/433 Volts capacity greater than 100 KVA & upto 250 KVA, of any make & any type all as directed.
Ditto all as per item No 32 above but for transformer of 11 KV/433 Volts capacity from 300 to 630 KVA of any make & any type all as directed.
M & L in replacement of worn out winding made out of paper covered super enamelled copper wire as per existing guage/size complete.
M & L in replacement of worn out winding made out of tripple paper covered solid copper wire as per existing guage/size complete.
Supply & fixing HV bushing with brass metal connecting rod, nut, bolt and washer suitable for transformer upto 630 KVA 12 KV as per IS 3347/1967 in replacement of worn out stud complete .
Supply & fixing LV bushing of transformer with brass metal connecting rod, nut, bolt and washer,suitable for 63 KVA to 100 KVA capacity of tranaformer 1100 Volt as per IS 3347/1967 complete.
Supply & fixing LV bushing of transformer with brass metal connecting rod, nut, bolt and washer,suitable for 200 KVA to 315 KVA capacity of tranaformer 1100 Volt as per IS 3347/1967 complete.
Supply & fixing LV bushing of transformer with brass metal connecting rod, nut, bolt and washer,suitable for 400 KVA to 750 KVA capacity of tranaformer 1100 Volt as per IS 3347/1967 complete.
Supply & replacement of silica gel crystal complete in all type of capacity of transformer all as directed.
Supply and fixing in replacement of Silica gel breather assembly complete with silica gel crystal complete for the capcity of transformer 50 KVA to 250 KVA all as directed.
Supply and fixing in replacement of Silica gel breather assembly complete with silica gel crystal complete for the capcity of transformer 300 KVA to 400 KVA all as directed.
Supply and fixing in replacement of Silica gel breather assembly complete with silica gel crystal complete for the capcity of transformer 500 KVA to 750 KVA all as directed.
Supply and fix in replacement DO fuse unit 3 pole 11 KV, upto 200 Amp channel mounted complete all as specified and directed.
Supply and fix in replacement DO fuse unit 3 pole 33 KV, upto 400 Amp channel mounted complete all as specified and directed.
Supply and fix in replacement of DO fuse element 5 Amp for 11 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 15 Amp for 11 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 25 Amp for 11 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 35 Amp for 11 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 40 Amp for 11 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 25 Amp for 33 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 30 Amp for 33 KV complete all as specified and directed.
Supply and fix in replacement of DO fuse element 40 Amp for 33 KV complete all as specified and directed.
Supply and fix in replacement of AB switch handle for 11 KV line complete all as specified and directed.
Supply and fix in replacement of AB switch female contact for 11 KV complete all as specified and directed.
Supply and fix in replacement of AB switch male contact for 11 KV complete all as specified and directed.
Supply and fix in replacement of AB switch pipe for 11 KV complete all as specified and directed.
Supply and fix in replacement of AB switch square bar for 11 KV complete all as specified and directed.
Supply & fixing in replacement lightning arrestor suitable for 11 KV grade, thyrester type, complete with all fitting transmission class for outdoor discharge capacity 65 KA complete.
Supply & fixing in replacement lightning arrestor suitable for 33 KV grade, thyrester type, complete with all fitting transmission class for outdoor discharge capacity 65 KA complete.
Supply and fix in replacement disc type insulator, porcelain, vitreous, white brown or green, 145mm high, and 255mm dia ball and socket type single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as directed. Make : Rashtriya /Jaipuria / Pactil /Alstom.
Supply and fixing in replacement 150 mm high and 150 mm dia pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for working pressure 11000 Volts grade complete all as directed. Make : Rashtriya /Jaipuria / Pactil /Alstom.
Supply and spreading graded stone aggregate of size 40 mm for transformer yard complete all as directed .
Dismantling and taking out damaged/rusted cross arms, MS channel or angle section etc complete and setting aside for reuse within 50 mtrs.
M&L for cross arms, bracings, supports, clamps and back plates from existing poles and structures and material and labour for cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed.
Fixing only cross arms of any type & size obtained from item No.66 here-in-above.
Material and labour for danger notice plate for HT of size 25x20cmx1.5mm thick mild steel sheet, synthetic enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts complete all as specified.
Material and labour for painting of 11 m steel pole with cross arms, clamp of any length and shape for HT overhead line with two coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking three black & two yellow bands width 30 cm by fluorescent paint, from bottom of pole to 1.5 mtr height, complete all as directed.
Labour charges for servicing/overhauling/repairing & testing of all protection relays , CTs,PTs and 33KV VCB breaker 1250 A out door type, including all circuit control wiring complete all as follows:- (a) CTs primary current injection test . (CT Testing) (b) Ratio test of PTs (c) Protection relays testing through secondary current injection kit (Relay testing) (d) Voltmeter,ammeter functional tesing (e) Breaker tesing for tripping time, closing time , contact resistance , IR values and physically healthyness of Vaccum interuptor.
Ditto all as item No 70 above but 11KV 630/800 A (Make : CG) indoor VCB panels all as specified and directed.
Taking out defective/wornout parts from 33 KV VCB at the time of overhauling and S&F in replacement, for the following all as specified and directed.
Closing coil
Tripping Coil.
Auxillary switch
Spring charging motor assy
PT Fuse
Motor cutoff switch
Breaker control switch
Taking out defective/wornout parts from 11 KV VCB at the time of overhauling and S&F in replacement, for the following all as specified and directed.
Closing coil
Tripping coil
PT Fuse Unit
Motor cutoff switch
Breaker control switch
Roller
Spring charging motor assy
Painting of transformer of capacity upto 250 KVA, 11/.433 KV with two coats synthetic enamelled spray painting after preparation of transformer surface complete all as specified and directed.
Ditto all as item No 74 above but capacity 300 to 630 KVA 11/0.433 V.
Taking down defective indication lamps and replace with new LED pilot lamps complete .
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for lectrical shock safety of sizes 2m x 1m complete.
Ditto all as per item No 77 above, but 2.5 mm thick for voltage upto 11 kv (size 2 x 1m)
Ditto all as per item No 77 above, but 3.0 mm thick for voltage upto 33 kv (size 2x1m).
Supply, installation¸ testing & commissioning of waterless and maintenance free earthing with earth (grounding) electrodes and PCC pit with cover. (a) Earth Electrode: 17.2 mm dia copper bonded MS rod shall be in-situ cast in electrically conductive concrete earth enhancing material mixed with cement. Size of embedding of electrically conductive concrete earth enhancing material shall be 85 mm dia. The electrode of 3000mm should be able to withstand a fault current upto 35kA (Peak) for 1 second duly tested from recognized National Test laboratories like CPRI, ERDA, ERTL, MSME etc (not more than 18 months old). The ratio of mixing of conductive concrete to cement should be 3:1. Other hardware like nut, bolts and washers should be of stainless steel.
M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32x6mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge.
M&L for painting to old chain link fencing and steel sections post with two coats aluminum paint over a coat of aluminium red-oxide complete including preparation of old steel or iron surfaces all as specfied and directed.
ENVIRO TECH SERVICES
ms shrilaxminarayan and sons
Auto Traders
R.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .