Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-Finance Rate quoted is lowest | |
| 2 | L2₹12.5 L+₹1.5 L (13.5%)Accepted-Finance | L2 | Accepted-Finance Rate quoted is second lowest | |
| 3 | L3₹13.4 L+₹2.5 L (22.4%)Accepted-Finance | L3 | Accepted-Finance Rate quoted is highest | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹20.8 L
EMD Value
₹21,000
Closing Date
21 Jan 2021, 4:00 pmClosed
Superintending Engineer
SE ETC Sultanpur 400KV S/S Campus Payagipur Sultanpur
CONSTRUCTION OF NEW 132KV TSS RAGHURAJ SINGH BAY (ALONG WITH CARRIAGE OF STRUCTURE 132KV SWITCHYARD EXTENSION AND EARTHING, LIGHT ENHANCEMENT IN EXTENDED SWITCHYARD) AT 132KV S/s, SARENI UNDER ETD, RAEBARELI
2020_UPTCL_541802_1
T. NO. 97/ETCS/2020-21
Open Tender
Electrical Works
Item Wise
90 days
Sultanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,478
SE ETC Sultanpur
₹21,000
27 Jan 2021
29 Dec 2020
22 Jan 2021
29 Dec 2020
21 Jan 2021
29 Dec 2020
29 Dec 2020 - 21 Jan 2021
Amount
Carriage of structure/materials from Electy. fabrication unit Naini Prayagraj/other Substations To 132 KV S/S Sareni.
Sorting, counting, stacking mark wise and head loading of structure on truck/tralier (12.68 MT)
Safe carriage of loaded structure from electy. fabrication unit Naini Prayagraj To 132 KV S/S Sareni-Raebareli. Distance approx. 150 km (12.68 MT X150 km=1502MT-KM)
Unloading of carriage structure from Truck/Trailer its Sorting, Counting and proper Stacking at the S/S premises as per direction of supervisioning engineer (12.68 MT)
Loading of 145 KV SF-6 Circuit breaker at 132 KV S/S Tripula, Raebareli & unloading of same at 132 KV S/S Sareni with the help of hydra, labour and T&P to be arranged by the contractor at his own cost.
Carriage of 145 KV SF-6 Circuit breaker from 132 KV S/S Tripula, Raebareli to 132 KV S/S Sareni, Raebareli including cost of Truck/trailer, labour and T&P to be arranged by the contractor at his own cost.
Cutting of length of MS round bar for suitable length, loading and unloading on truck/heavy vehicle for carriage at 220KV S/S Hardoi road, Lucknow/Designated place including cost of labour and T&P required for same.
Carriage of 02MT 40mm MS round bar from 220 KV S/S Hardoi road, Lucknow to 132 KV S/S Sareni, Raebareli including cost of Truck/trailer, Labour and T&P required for same.
Erection of following structure/equipments as per instruction of various equipments manuals and technical specifications including shifting of structures/equipments from store to erection site including all other associated works for completion of erection work satisfactorily:-
Main structures (ATMS(with Peak & Mast)-02Nos., BTM-02Nos., AXM-03Nos.)
Auxiliary structures (BBL-02 Nos, BTI-01 Set., BCT-06 Nos., ALP-05 Nos)
132 KV SF-6 Circuit Breaker
132 KV C.Ts
132 KV Bus Isolator without earth blades
132 KV Line Isolator with earth blades
132 KV Tandem Isolator
120 KV Lightening Arresters
132 KV C.T./P.T. Junction box
145 KV Post Insulators
Gear box mechanism of 145 KV LSI, BSI & TI
Main & check ABT Meters in ABT meter cubicle.
Extension of 132 KV Main & Transfer bus by Stringing of single Moose conductor bus including fixing of clamp, tension fitting & all other associated works. (3PhaseX 02Nos=06)
Jumpering of all equipments of 132 KV feeder bay with ACSR Panther conductor between Main & Transfer bus including all droppers with help of suitable clamps/fittings to be provided by department including hoisting of 120 KN disc insulator on each phase on 132 KV gantry with suspension clamps and required cutting and bending of conductors.
Earthmat laying in extended switchyard for 132 KV TSS Bay.
Fabrication of 3M long 40mm diameter electrode with following MS Rod having 150mm long conical shape and then its piercing vertically inside the ground with top 50mm below ground level and its welding with earth mat excluding the cost of MS Bar.
Extension of MS Round Bar Earth Mat 40mm by digging of earth cutting, laying, welding and back filling of earth and doing all other associated work to complete the job satisfactorily excluding cost of MS Round Bar.
Cutting, straightening & laying of following MS flat 700 mm below inside ground and above ground of 50 mm x 6 mm size and 25 mm x 6 mm size MS Flats for earthing of main auxiliary structures, equipment and cable trenches including welding with main earthmat and with the object to be earthed excavation of trenches its back filling painting and all other associated work to complete the earthing work satisfactorily as per technical specification.
Earthing of main structures with 75 mm x 6 mm size MS Flat.
Earthing of main structures with 50 mm x 6 mm size MS Flat.
Earthing of auxiliary structures and equipments with 25 mm x 6 mm size MS Flat.
Earthing of cable trenches/Racks with 25 mm x 6 mm size MS Flat.
Prepartion of Interconnection diagram of cable schedule as per drawings to complete job including C.B., C.T., Isolators etc. & submission of same in hard bound sets of 03 copies to the department.
Laying of following size of control cables in the cable trenches and relay panels in control room to various equipments, junction boxes, etc. in switchyard as per cable schedule its saddling with 25X3mm size including carriage of cable drums from stores to work site and shifting back to store with all other associated works to complete the job satisfactorily as per technical specifications:-
Laying of 2X2.5 sqmm size control cable
Laying of 4X2.5 sqmm size control cable
Laying of 6X2.5 sqmm size control cable
Laying of 10X2.5 sqmm size control cable
Supply & laying of following size of GI pipe B class for conduiting of control cable (metering) complete with elbow, Tee, socket reducer as per site requirement in the switchyard.
50 mm dia GI B class (medium) pipe for conduiting.
40/25 mm dia GI B class (medium) pipe for conduiting.
Shifting of 132 KV Distance Protection Panel from store of substation to the control room/kiosk room and fixing of panels by grouting new bolts etc. with all associated works i.e. earthing of panel alongwith all terminations with neat dressing of cables at control room end at new panels.
Shifting of 132 KV ABT Meter Cubicle from store of substation to the control room/kiosk room and fixing of panels by grouting new bolts etc. with all associated works i.e. earthing of panel alongwith with terminations of cables with neat dressing of cables at control room end at new panels.
Delta earthing of 120 KV LA consisting of 06 nos. electrode its placing inside the ground and connecting all three electrodes with M.S. flat and connecting the same with main earthmat at two place required excluding cost of MS strip and MS roud bar.
Lighting enhahcement in extended switchyard for 132 KV TSS Bay.
Providing & fixing of new generation energy & environment friendly long aluminium outdoor beam street light with high power 120 watt LEDs as light source & exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 Volt AC input supply of CGL/Havells/ Surya/Philips/Bajaj etc. Including wiring from junction box to light fitting point and checking of healthyness of LED lights.
Supply and fixing of steel round pole (B Class) 9.0 mt long with 1.5 meter long bended at 1 meter at an angle of 300 for light in switchyard.in 1:4:8 cement concrete with 40 mm brick ballast in size of 450x450x1900 and plastering of 300 mm length of concrete above ground level.
Supply and installation of junction box of size 280x225x150 mm made of 16 SWG sheet with grey painting suitable for 2x4x6 C sq mm incoming cable and 2x4x6 C sq mm outgoing cable fitted with 03 Nos. HRC fuse link of 5 Amp. cable glands, nutral link, terminal block etc and fixing of junction box on columns with the help of 50x6 mm GI Clamp.
Supply and fixing of pipe bend of 50/35 mm dia GI 'B' Class pipe 1.5 meter long bended at 1 meter at an angle of 30o for light in switchyard.
Taking out 2C x2.5, 4Cx2.5 sq mm copper control cable from junction box light fittings fixed over the column by fixing G.I. clamps of 40x5mm flat with each crossed bracing on structures.
Providing & Fixing of outdoor type AC power supply cubical of 16 SWG MS sheet Vermin proof having 03 Nos. Alu. Bas Bar for RY B-Phase and 01 No. netural bas bar of size 25x12 mm and 25x6 mm respectively. The cubical will have 16 Nos. 32 Amp. 3 Phase MCB And 08 Nos. 06 Amp. Singal Phase MCB of Havell's make with indication Lamp wiring detail as per tech. specification.
Termination of ACDB by L.T. power cable of size 95/50 sq. mm includes laying and termination of cable with crimping of lugs etc.
Laying of L.T. power cable of size 95/50 sq. mm for ACDB from control room to designated point for ACDB.
Providing & Fixing of Name Plate made of 2mm Thick Alu. sheet with covering of 3M HIP/ Equivalent retro reflective sheet of size 300mmx150mm plate to fixed with the help of Nut & Bolts already installed equipement (C.B.-01No., BSI-01 No., LSI-01No., DPP Panel-01No., Metering Panel-01No., Shutdown Board-01No.) (content to be printed on Name Plate will be provided by department)
Providing & Fixing of Phase Plates made of 2mm Thick Alu. sheet with covering of 3M HIP/ Equivalent retro reflective sheet of size 300mmx150mm plate to fixed with the help of Nut & Bolts already installed equipement (C.T. - 02 Nos., P.T.-02 Nos., L.A.-02 Nos., B.T.I.-03 Nos.) (content to be printed on Phase Plate will be provided by department)
Painting of all sizes of M.S. flat/strips above ground with one coat of red oxide primer and two coat of synthetic enameled green Japan paint after thorough rubbing and cleaning of strips including the cost of paint.
Assisting in complete testing and commissioning of all equipments of bay
Supply:- PG Clamp (As per sample)
Moose To Moose
Moose To Panther
Panther To Panther
Five Bolted Single tension fitting suitable for Moose type conductor (as per sample)
Complete set of Single Suspension fitting suitable for Panther type conductor (as per sample)
Copper Bond of Length 500 mm and 16mm dia crimped on both sides with copper lug of 16mm dia.
145 KV Bus Post Insulator (BPI) clamp for Twin Panther (as per sample).
145 KV C.T. clamp for Twin Panther (as per sample).
145 KV P.T. clamp for Twin Panther (as per sample).
145 KV Isolator clamp for Twin Panther (as per sample).
SHIVAM ENGINEERS
M/s Janta Charan
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .