Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 7 2 S F ARIHANT ARCADE CENTRAL MARKET SHASTRI NAGAR MEERUT U P 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.7 L+₹2.3 L (7.18%)Rejected-AOC DEHRADUN | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.9 L+₹3.4 L (11.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical 93 1 PREMPURI KANKER KHERA MEERUT INDEX NO E MER 81 HQ CWE MEERUT | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
26 Jul 2021, 6:00 pmClosed
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
CLEANING, PAINTING AND MARKING OF OVER HEAD RESERVOIR AT VARIOUS PUMP HOUSE OF SOUTH AREA OF AGE E/M WS UNDER GE(U) E/M MEERUT CANTT.
2021_MES_452161_1
8339
Open Tender
Civil Works
Item Rate
150 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(U) E/M Meerut Cantt
₹84,000
Yes
18 Sept 2021
18 Jun 2021
2 Aug 2021
18 Jun 2021
26 Jul 2021
12 Jul 2021
18 Jun 2021 - 26 Jun 2021
Amount
Dismantling of old existing unserviceable/ broken valve pit and M&L for construction of Brick masonry valve pit of 1200mmx1200mmx1200mm internal size consisting of Mild steel frame and cover complete complete all as specified and shown in drawing No. CEBZ drg No. TD/EM/12
M&L Earth filling under floors/ pathways etc. or in foundations including watering and consolidation complete all as specified. ( Note:- Earth for filling shall be arranged by Contractor from outside defence land and the cost thereof shall deem to be included in the unit rate quoted by Comntractor.)
M&L broken bricks hardcore of gauge n exc. 63 mm , deposited , spread and levelled in layer n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L Plain cement concrete type C2 (1:3:6), using 40 mm graded crushed stone aggregate,75 mm thick , as in floor/path/ plinth protection,top finished even and fair complete all as specified.
M&L rendering 10 mm thick on concrete or on fair faces of brickwork walls , in cement and sand mortar 1:4 top surfaces finished fair and even complete all as specified
Taking down cement plaster on brick or stone walls , concrete block walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. and removing of the rubbish complete all as specified .
M&L two coats of exterior emulsion paint , white or tinted on old surfaces of RCC reservoir walls at any height including prepration of old decorated plastered/ unplastered surfaces aincluding washing, rubbing down and stopping of distempered and painted surfaces, washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L two coats of exterior emulsion paint , white or tinted on old surfaces of RCC reservoir ceiling at any height including prepration of old decorated plastered/ unplastered surfaces aincluding washing, rubbing down and stopping of distempered and painted surfaces, washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L preparation of old painted steel and iron surfaces of any description , not otherwise described ,over 10 cm width or girth and painting two coats with synthetic enamel including cleaning, stopping and rubbing down and removing all drops , , dirts etc. complete all as specified.
M&L Writing letters or figures ( Block , Roman, Italic or Indian ) n exc 30 cm high with thick synthetic enamel paint with out showing signs of brushes mark ( if necessary they shall be repainted until the desired result obtained) all as specified.
Taking out stored water from chlorination sump well ( 1500mmx1500mmx1200mm) and removing to a distance not exceeding 50M and depositng where directed completed all as specified.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 25000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where directed by Engineer-in-Charge including S&F Flex Board of size 450mmx300mm duly printed with details e.g Tank Cleaned on:- date, month and year to be mentioned, complete all as specified and indicated.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 50000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where directed by Engineer-in-Charge including S&F Flex Board of size 450mmx300mm duly printed with details e.g Tank Cleaned on:- date, month and year to be mentioned, complete all as specified and indicated.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 100000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where directed by Engineer-in-Charge including S&F Flex Board of size 450mmx300mm duly printed with details e.g Tank Cleaned on:- date, month and year to be mentioned, complete all as specified and indicated.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 200000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where directed by Engineer-in-Charge including S&F Flex Board of size 450mmx300mm duly printed with details e.g Tank Cleaned on:- date, month and year to be mentioned, complete all as specified and indicated.
Cleaning of internal surafces of RCC overhead tanks/ Reservoirs of 450000 gallons capacity at 21 M height by using high pressure rotary jet machine and pumping out/ flushing out water, mud, sludge, dirt etc by any means of industrial vaccum cleaner including brooming down or steel wire brushing; scrapping down, moulds, moss and efflorescent salts and washing the inside surfaces including pipes, ladders etc. and treating the surfaces by spraying sodium hypochlorite (anti bacterial agent) in a concentration as directed by means of high pressure rotary jet machine & UV radiation disinfactant, disposing off the spoils to a distance not exceeding 50 M in a safe manner where directed by Engineer-in-Charge including S&F Flex Board of size 450mmx300mm duly printed with details e.g Tank Cleaned on:- date, month and year to be mentioned, complete all as specified and indicated.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 25 x 4 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 40mm thick precast RCC 1:2:4 type B-1, duly reinforced with 8mm dia TMT bars @ 150mm C/c and 6mm dia bars in lifting handles amd MS angle frame of angle iron 40x40x5 mm thick, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Taking down existing wornout Flex Board and S&F of PVC sheet weighing 350gm/sqm flex duly fixed on a aluminium pipe frame work made out of 40mmx40mmx2mm thick pipe by suitable means.Flex Board of size 900mmx1200mm fixed to walls with and including stainless steel nuts, bolts and washers duly printed (embossed) with the line diagram in desired colour of water supply and allied connections of Pump house as per sample format provided by Engineer-in-charge complete all as specified..
Taking down existing wornout Flex Board and S&F of PVC sheet weighing 350gm/sqm flex duly fixed on a aluminium pipe frame work madeout of 40mmx40mmx2mm thick pipe by suitable means.Flex Board of size 900mmx1200mm fixed to walls with and including stainless steel nuts, bolts and washers duly printed (embossed) with the specifications of pump, including its year of commissioing, capacity, make, MES /Machine No., supplied areas, interconnection etc. in desired colour of water supply and allied connections of Pump house as per sample format provided by Engineer-in-charge complete all as specified..
Sampling of chlorinated water from various pump houses under AOR of AGE E/M WS Meerut as and when directed by Engineer-in-Charge and testing the water for bacteriogogical , Physical and chemical as per IS-1622 and 3025 from any Government/NABL approved laboratories and submission of test report to Engineer-in-Charge complete all as directed. Note:- Sampling shall be done by the authorised rep of the approved laboratory from whom the testing of water is to be carried out in presence of JE/EIC).
Taking down of unserviceable /wornout LED aviation light fitting with GI strips of any size including wiring and S&F LED aviation obstruction light luminaires , die cast aluminium alloy housing with red polycarbonate dome, integral driver, min 5mm x 302 Nos LEDs, IP-65, short circuit and serge protection, 100V -270 V AC operating input voltage, life time 50000 Hrs , system wattage at 240V-10 to 12 watts comprising 5 parallel circuit maximum 10-12 W consumption and fixed with and including bracket made out of 20mm or higher dia of GI pipe light grade, 1.2M long having suitable fixing arrangement at botton made out of FI 50x6mm , fixing bolts etc, M&L wiring with two single core ,1.5 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including stove enamelled rigid mild steel surface conduit and conduit fittings not less 20mm noiminal dia with 1.5 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire (length of wiring from aviation light fitting to panel of Pump house 25M Approx) complete all as specified.
Sampling of non chlorinated water from various pump houses under AOR of AGE E/M WS Meerut as and when directed by Engineer-in-Charge and testing the water for bacteriogogical , Physical and chemical as per IS-1622 and 3025 from any Government/NABL approved laboratories and submission of test report to Engineer-in-Charge within 10 days of direction for testing complete all as directed by Engineer-in-Charge . Note:- Sampling shall be done by the authorised rep of the approved laboratory from whom the testing of water is to be carried out in presence of JE/EIC).
Sunil Enterprises
M/S KRISHNA KAVYANSH BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .