Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 CrAccepted-AOC | ₹5.7 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.9 Cr+₹13.6 L (2.37%)Rejected-Finance B XI 746 STREET NO 6 BHARAT NAGAR BARNALA 148101 | BARNALA | BARNALA | PUNJAB | 148101 | ₹5.9 Cr+₹13.6 L (2.37%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹6.9 Cr+₹1.2 Cr (20.7%)Rejected-Finance NOT SPECIFIED | ₹6.9 Cr+₹1.2 Cr (20.7%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹8.1 Cr+₹2.4 Cr (41.4%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹8.1 Cr+₹2.4 Cr (41.4%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹9.6 Cr+₹3.9 Cr (67.7%)Rejected-Finance F 31 INDUSTRIAL AREA PHASE VIII SAS NAGAR MOHALI 160071 | S A S NAGAR | PUNJAB | 160071 | ₹9.6 Cr+₹3.9 Cr (67.7%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹5.5 Cr
EMD Value
₹6.0 L
Closing Date
23 Sept 2022, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT-110010
PROVISION OF STP/CSS AT AF STN SARSAWA
2022_MES_528310_1
CEWAC/SAR/T-07/2022-23
Open Tender
Civil Works
Lump-sum
1545 days
GE (AF) SARSAWA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE(AF) SARSAWA
₹6.0 L
Yes
6 Jan 2023
9 Jun 2022
30 Sept 2022
9 Jun 2022
23 Sept 2022
16 Sept 2022
9 Jun 2022 - 27 Jun 2022
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
STP MECHANICAL, CIVIL COMPONENTS AND BUILDINGS Supply,installation,testing & commissioning of 760KLD capacity STP at AF Stn Sarsawa suitable to treat the sewer with treated water quality as mentioned in annexure 'A', Details of STP main components are shown in drg & are as under:- (a) INLET CHAMBER - 01No. (i) Minimum Size : 1.76m(L)x1.5m(W)x0.3m water depth + 0.5m free board (ii)Material & grade of construction : RCC M-30 concrete (iii) Quantity of flow (Ave) - 760 cum/day, (iv) Peak flow - 2280 cum/day or 0.0264 Cum/Sec, (v) Asummed detention period - 30 sec, (vi) Velocity at outlet required - 1.5 m/s, (vii) Outlet size - 150 x 120mm, (b) FINE BAR SCREEN CHAMBER - 01No. (i) Minimum Size : 3.6m long with 16 bars of 6mm thick made of SS 304 + 0.3 m free board (ii) Material & grade of construction : RCC M-30 concrete (iii) Peak Design Flow - 0.0264 Cum/Sec, clear spacing between bars - 0.01 m (iv) Velocity ahead of screen - 0.60 m/sec(maximum permissible) (v) Area of Screen Channel - 0.05 Sqm (vi) Considered width of channel before screen - 0.20m (vii) Water depth upstream - 0.25m (viii) Each opening of width - 6mm (ix) Total number of opening - 17 Nos(x) Total number of Bar - 16 Nos (xiii) Assume angle of inclination - 60 deg, (xiv) Inclined height of screen H1(Liquid depth) - 0.23m, (xv) Velocity through the screen (Vs) - 1.20 m/sec, (c) GRIT REMOVAL CHAMBER -01No (i) Minimum Size 3.5m(L) x 0.7m(W) x 0.6m water depth + 0.5m free board (ii). Material & grade of construction : RCC M-30 concrete. (iii) Peak flow - 2280 cum/day.
(d) EQUALIZATION TANK (COLLECTION CHAMBER)-1No (i) Minimum Size 9.0m(L) x 8.5m(W) x 2.5m water depth + 0.75m free board (ii). Material & grade of construction : RCC M-30 concrete. (iii) Peak Design flow - 2280 cum/day, (iv) Depth of liquid column - 2.5m, (v) Air requirement in equalization tank - 2.85 Cum/min. (vi) Item also includes provn of suitable size MS Ladder with railing and Air grid of suitable size as per approved drg. (e) RAW SEWAGE PUMPS- 02Nos (1W+1S/by) Non clog ,vertical submersible pumps with chrome steel impeller and cutter, non-clog to pass 40 mm size with guide rail and lifting chain, cables etc., for pumping sewage from Equalisation Tank to MBBR reactor having characteristic as specified below :- (i) Average flow - 760 cum/day, (ii) No of working hrs - 16 hrs, (iii) Flow capacity - 47.50 cum/hr, (iv) Head - 20.0m (min) (v) Proposed flow of each pump - 800 LPM (min) (vi) Item also includes provn of level sensor and all connected items for automatic operation of the pumps. (f) AERATION TANK (MBBR)- 02Nos Two nos Aeration (MBBR) tanks, BOD at inlet - 250 mg/L, BOD at outlet - 10 mg/L, BOD reduction - 240 mg/L, Total BOD removed- 182.4 kg/day, made of M30 grade concrete of following sizes:- i) MBBR-1 of minimum size 5m(L)x5.8m(W)x3.5m liquid depth + 500mm free board all as specified below :- a) BOD loading - 7.5 g/sqm/day, b) Volume of MBBR - 102 cum (min)
c) Media volume (50% of MBBR volume) - 51 cum (min) d) Water depth- 3.5m (e) Suitable size SS pipe air grid as per OEM recommendation. ii) MBBR-2 of minimum size 5m(L)x3.2m(W)x3.2m liquid depth + 500mm free board all as specified below :- a) BOD loading - 1.5 g/sqm/day, b) Volume of MBBR required- 51 cum (min) c) Media volume (50% of MBBR volume) - 25.5 cum (min) d) Water depth- 3.2m, (e) Suitable size SS pipe air grid as per OEM recommendation.
(g) SECONDARY CLARIFIER (TUBE SETTLER) - 01No. Secondary clarifier (tube settler) tank made up of M30 grade concrete of min size 6.3m (L)x5.0m(W)x2m water depth +0.5m free board all as specified below. (i) Width of secondary settling tank- 5m, Length- 6.1m, Depth of clarifier - 2m, volume of clarifier - 60.8 cum, (iiTube settler internal of Square Tube type lamella PVC plate in secondary clarifier . (h) EXCESS SLUDGE TANK- 01No. Excess sludge tank made up of M30 grade concrete of minimum size 6.3m(L)x2m(W)x3m(D) + 0.5m free board all as specified below:- (a) Liquid depth- 3000mm. (j) AIR BLOWER - 03Nos (2W+1S/by) Supply & fix twin lobe, roots type oil free positive displacement screw Air Blowers of designed capacity and head with min 500 cum/hr flow rate of each blower. driven through V belt or directly coupled through flexible coupling to a TEFC motor of suitable HP, 3- phase supply, 415V, 50 cycles and complete in all respect all as specified and directed and shown in drg.
(k) SLUDGE RECIRCULATION PUMP -02Nos (1W+1S/by) Supply and fix Centrifugal non clog type Sludge Recirculation Pumps for circulating sludge from secondary Clarifiers to the sludge Aeration Tank. Min pump capacity 0.3 cum/hr @ 15 m head or as with OEM recommendation complete in all respect. (l) FILTER PRESS FEED PUMP -02Nos (1W+1S/by) Supply and fix Helical screw pumps suitable to handle solid above 10mm and capacity not less than 0.1 cm/hr and min 15m head. (m) CHLORINE CONTACT & DOSING TANK -01No. (i) Minimum size 5.0m(L)x4.0m(W)x2.3m(D) + 0.5m free board (ii) Material & grade of construction : RCC M-30 concrete. (iii) Chlorine dosing rate- 0.8mg/L, (iv) Percentage of chlorine in bleaching powder - 25% (v) Density of solution- 1 gm/ml (vi) Strength of solution- 1% (vii) Bleaching powder req- 2.144 kg/d (viii) Dosing rate- 9.00 LPH tank min (ix) Volume- 46 cum
(n) HYPO DOSING SYSTEM - 02Nos : Hypo dosing system consisting of metering type dosing pump in PP construction and LDPE/HDPE of designed 150LPH pump closer and tank capacity 1000 liter or as required complete with metering, piping and valve accessories. (o) PAC DOSING SYSTEM-02Nos: Poly Aluminium Chloride (PAC) dosing system consisting of metering type dosing pump in PP construction and LDPE/HDPE dosing tank of designed capacity. (p) AIR GRID: One Lot of Air Grid of Coarse Bubble, Lateral & Header type in SS 304 construction for Equalisation Tank and MBBR reactors. Non-clog type air dispersion system capable 3-5 cfm of air or as required with oxygen transfer efficiency of 5 - 6% per/meter water depth, fine bubble membrane diffusers complete in all respect with fittings, pipe, air flow meter, valve ,support ,clamps and accessories duly connected with flower. (q) 1 Lot of floating media for MBBR reactors in PP construction wagon wheel design having density less than water. (r) 1 Lot of Tube settler internal of Square Tube type lamella PVC plate in secondary clarifier . (s) SCREW/ FILTER PRESS:Supply and commissioning of screw press for dewatering of sludge having capacity 3.0 cum/hr at sludge concentration of 1% & solid at outlet : 20-22%. Filter press with filter cloth PP filter element size of plate 300x300 and 13 no. of plates. (t) FILTER FEED PUMP -02Nos (1W+1S/By): Supply, install, testing and commissioning of Horizontal centrifugal non clog water transfer pumps Cl body motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia) for the pump. The pump shall be suitable for 415±10% volts 3 phase AC supply. Having specification as below: Capacity :528 LPS each Head @26m
(u) ACTIVATED CARBON FILTER -01 Sets : Providing, fixing, testing & commissioning of vertical MSEP Activated Carbon Filter with adequate dirt holding capacity (suitable for 3.5 Kg/Sqcm working pressure). As per manufacturer's specifications complete with intitial charge filter media . The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping & Valves. Min Filteration Rate 15000 L/Sqm/Hr .Test pressure : 5.5 Kg/Sq.cm .Flow Rate : 25.0 m3/hr(min). (v) DUAL MEDIA FILTER - 01Set : Providing, fixing, testing & commissioning of vertical MSEP Dual Media filter with adequate dirt holding capacity (suitable for 3.5 Kg/Sqcm working pressure). As per manufacturer's specifications complete with intitial charge filter media . The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping & Valves.Filteration Rate 15000 L/Sqm/Hr .Test pressure : 5.5 Kg/Sq.cm .Flow Rate :25.0 m3/hr. (w1) Treated Water Tank - 01No (i) Minimum Size - 5m(L) x 4m(W) x 2.3m water depth + 0.5m free board (ii) Material & grade of construction - RCC M-30. (w2) Pump house & Tertiary treatment plant: (i) Area 50Sqm with 3.50 mtr Height (ii) Material & grade of construction: RCC M-30 concrete & brick work. (w3) Store : (i) Minimum size: 4.80mtr(L)x2.50mtr(W)x3.50mtr Height (ii) Material & grade construction : RCC M-30 concrete & brick work. (w4) Toilet : (i) Minimumsize: 1.27mtr(L)x2.14mtr(W)x3.50mtr Height (ii) material & grade construction : RCC M-30 concrete & brick work. (w5) Collection sump: (i) Minimum size: 5.0mtr inner dia x 8.10 mtr total effective depth as on shown drawing (ii) Material & grade construction : RCC M-30 concrete (iii) Coarse screen as specified & shown drawing (iv) RCC stair case with landing & 900mm High Railing as shown on drawing. (x) FLOW METER - 02Sets Supply of Electromagnetic flow metre at Inlet and Outlet of STP of suitable Dia.
National Electricity Manufacturers Association (NEMA) International Electro-technical Committee (IEC) American National Standards Institute (ANSI) The Institution of Electrical and Electronic Engineers (IEEE) 18 Input/ Output Modules a) Standard rack mounted I/O modules with plug-in cards shall be provided. Field wiring shall be terminated in screwed terminal and interconnected to the processor I/O system with pre-fabricated cables with plug-in type connectors. b) 20% extra points of installed capacity for each type of input shall be provided as spares and shall be wired to the terminal block of the control panel. Provision shall be made for future expansion of extra I/O modules. c) Some of the common features of the I/O modules shall be as follows : i. All inputs shall be terminated with input protective network and necessary isolating barriers. ii. Filters for noise rejection. iii. Provision for isolation of faulty channels. iv. Protection for continuous overload up to 200% of all input ranges. (aa) ONLINE PARAMETER ANALYZER -01 Set : Online Multi parameter analyser with sampling pump based on advanced microprocessor to monitor COD, BOD, TSS and PH , complete as specified in particular specifications as per Annex - B (ab) ONLINE CHLORINE ANALYZER -01 No.: Online chlorine analyser for measuring of residual chlorine in the treated water, as specified in the particular specifications as per Annex- C.
(ii) Treated water transfer Pump : Automatic Star delta starter dry type 15HP motor, MCB TPN 32-63Amp 415V,10KA, single & reverse phase preventer,over load relay, contactor, timer etc of suitble rating multifunctional digital meter, ON/OFF/Trip LED indicater lamps, and push button as required - 02set (iii) MCB SPN 16-32 Amp, 50 Hz, 415 V ,10KA -03No (,bldg internal & 02 spare).Note for panels : (i)The panel shall consist of PLC with integral alarm annunciator & all required hardware and software. (ii) Test points and fault indication LEDs shall be provided to carry out module testing. (iii). Surge withstands facility as per IEEE standards. (iv) All the modules shall be of addressable type. (v) Fuse protection and fuse failure detection. (vi)Internal battery backup. (vii)All pumps, blower or motors having standby units, to be run 24 hours, should be controlled for auto interchangeability after pre-set time. (viii) Cable entry – Bottom. (ix)Relays and protection shall be enabled for SCADA with IEC 61850 protocol & Modbus RS-485. Note for complete STP: (i) The items and BOQ is deemed to include all necessary internal piping , valves required for interconnection & flow regulation of all equipments of STP, Cables from electric control panel upto pumps of size as per load requirement for commissioning and smooth functioning as shown in drg. (ii) STP shall be installed by OEM only. (iii) The items which are not specifically mentioned but are required for smooth & efficient functioning of plant are deemed to b included in the quoted rates. Notes for Civil Components and Buildings: (i) Civil components and Buildings as shown on drawings will be deemed to be included in quoted lumpsum.
Construction of Tech Lab, panel room alongwith toilet Building with permanent specification and as specified as shown on complete drawings.
NOTE: Schedule ‘A’ Part II to XI under are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORKS” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE WORKS & MANHOLES” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “APPROACH PATH/ROAD/HARDSTANDING WORKS" as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “FENCING AND GATES" as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part -VIII
Lump sum price worked out by the Contractor for “UPGRADATION OF OXIDATION PONDS WORKS ” as listed in Schedule ‘A’ Part -IX
Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING WORKS" as listed in Schedule ‘A’ Part X
SCHEDULE `A' PART -XII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
SEWAGE TREATMENT PLANT
TREATED WATER RE-USE Supplying, installing, testing & commissioning of Horizontal centrifugal water pumps with CI Head & Base, Impeller, CI Shaft along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia) for the pump. The pump shall be suitable for 415±10% volts 3 phase AC supply .Capacity :75m3/hr eachHead@ 35 meter. (1 Working + 1 Standby). Note: Provision of suction pipe from treated water tank to pumps and delivery header alongwith cabel from starter panel to pump motor is deemed to be inclusive in the item quoted rate.
Material & labour for masonary valve chamber, TYPE 'A' including PCC (1:4:8) type D2 foundation & floor, brick work in CM (1:4), internal & external plaster 10 mm. All complete as per standard details and as per specifications.
Material & labour for masonary valve chamber, TYPE 'B' including PCC (1:4:8) type D2 foundation & floor, brick work in CM (1:4), internal & external plaster 10 mm. All complete as per standard details and as per specifications.
Supply and lay 3 layer(inner antimicrobial outer UV stabilized) ISI marked , IS-15801, PP-R pipes SDR 11 (PN-10) and PPR plain fittings in trenches complete of size outer dia 160mm including all fittings.
Supply and lay 3 layer(inner antimicrobial outer UV stabilized) ISI marked , IS-15801, PP-R pipes SDR 11 (PN-10) and PPR plain fittings in trenches complete of size outer dia 110mm including all fittings.
Supply and lay 3 layer(inner antimicrobial outer UV stabilized) ISI marked , IS-15801, PP-R pipes SDR 11 (PN-10) and PPR plain fittings in trenches complete of size outer dia 75mm including all fittings.
Supply and lay 3 layer(inner antimicrobial outer UV stabilized) ISI marked , IS-15801, PP-R pipes SDR 11 (PN-10) and PPR plain fittings in trenches complete of size outer dia 50mm including all fittings.
Supply and lay 3 layer(inner antimicrobial outer UV stabilized) ISI marked , IS-15801, PP-R pipes SDR 11 (PN-10) and PPR plain fittings in trenches complete of size outer dia 25mm including all fittings.
M & L for trenchless boring for crossing pipes under roads on rental basis complete all as specified and directed.
Supply and fix Valves, Sluice, flanged of class PN- 1.0, 150 mm (6”)dia complete all as specified and directed.
Supply and fix Valves, Sluice, flanged of class PN 1.0, 100 mm (4”)dia complete all as specified and directed.
Supply and fix Valve, globe conforming to IS 9338, 50mm (2”) dia pipe complete all as specified and directed.
Supply and fix Non Return Valve, butterfly conforming to IS 13095,100 mm (4') dia complete all as specified and directed.
Supply and fix Non Return Valve, butterfly conforming to IS 13095,50 mm (2`) dia complete all as specified and directed.
Supply & fix RV Brass Foot Valve 1021 Premium Pack Brass Foot Valve Screwed Ends. (80MM|3") complete all as specified and directed.
Sypply & fix Fully automatic water level controller with dry run protection single phase, Anti corrosion stainless sensor, Contact capacity : 30 A, Start, stop, auto, manual switch, Tank water level indication, pump on indication
INTERNAL ELECTRIFICATION
S&F batten type lamp holder with LED lamp 8 watt complete all as specified and directed.
S&F sheet metal enclosures for MCBs, single pole and neutral, 6 ways 240 volts double door type complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, B Curve type 10 KA breaking capacity 240 volts complete all as specified and directed.
S&F MCB SPN 16 to 32 Amps, B Curve type 10 KA breaking capacity 240 volts complete all as specified and directed.
STANDBY ELECTRIC SUPPLY
Supply and install , testing and commissioning of diesel engine driven generating set 100 KVA with water cooled engine for power generation @ RPM 1500, brushless frame with silencer and Canopy for sound less mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/dynamo and 80 KW/ 100 kVA electric alternator, 415 volts, 3 phase, 4 wire,50 Hz, Voltage Regulation ± 5, Insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components, fuel tank of capacity of not lesss than for 12 hour run with level indicator installed on suitable steel frame with PCC foundation as per manufacturers instructions, Power Command genset Controller, fuel pipes, Dual spin on fuel filter, Dry type Aircleaner, Shutt off coil with safeties for LLOP/HWT , fuel pipes , bar metre, hour meter , oil temperature gauges, ammeter, ignition switch, radiator with cooling fan, maintanance free battery 12 V 1x92 AH, with charging provision, Exhaust emmission Silencer aluminium clad,emergency stop button, machanical governor, with power starter controlled microprocessor based unit, LED in side canopy with including suitable size of copper cable leads with terminals, all mountings ,accessories and necessary foundation and AVM pads complete as per manufacurers recommendations and to the satisfaction of all as specified and directed.
(A) PRIME MOVER :- Suitable for driving 64 KW/100 KVA alternator water cooled battery staart diesel Engine of suitable capacity confirming of ISO 3046 / BS 5514 BSS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 hrs operaton complete with the following standard accessories :- (B) ALTERNATOR : 64 KW/100 KVA at 0.8 PF Brushless self excited, self regulaed 3 phase 50 Hz 415 V 1500 RPM 4 wire screen protected drip proof free from simulation problems continuous rating confirming to BS 5000 complete with automatic voltage regulator O/P voltage regulated between +/- 1% or set voltage from no load to full load. Note: i) any fittings/fixtures which are necessary for properfunctioning of the DG set shall also be deemed include in the unit rate quoted and shall be provided by the contractor without any extra cost to the Deptt. ii) Necessary foundation for installation of DG set shall be provided as per manufaturers recommendations and cost deemed to be inclusive in the rate quoted for this item. iii) All testing equipments and FOL are to be arranged by the contractor and testing shall be carried out by the contractor in presence of re of Accepting Officer. iv) Rate quoted by the contractor including the rate of first filling of lubricating oil, Coolent(v) Drawings/cataloge for DG Set shall be got approved by the GE before ordering to the manufaturer
EXT ELECTRIC SUPPLY
Supply, installation, commissioning and testing Transformer, Step down, outdoor, pole mounted ,double copper wound, 3 phase, 50 Hz, AC, Oil immersed, natural air cooled, external cooling tubes/radiator core types having no load voltage ratio 11000/433 Volts (Corresponding to principal tapping) winding delta connected on primary side (HV Side) and Star connected on secondary side (LV Side) in accordance with vector symbol DYN-Il (vector group) with neutral brought out on LV side and having looping on HV side for contact output so as to alter/vary secondary voltage by ± 7.5% in steps of 2.5% to be changed by means of off load taps changing gear. The limit of temperature rise after continuous fall load run as specified in IS:1180(Pt-1) of 2014 shall be suitably adjusted to suit to the ambient temperature of maximum 48 degree Celsius prevailing at site all as specified of rating 100 KVA. The losses at 50% load & 100% load shall be not more than 435 Watt & 1500 Watt respectively.
Supply and fix LED street light 35/36 W IP 65, lumen efficiency not less than 100Lm/watt, operating voltge 140-270V, driver with surge protection 5KV with overload & short cuircuit protection, pf more than 95%.
Supply & fixing Hot dipped galvanized octagonal pole of 6 mtr height having top dia 70mm,bottom dia 130mm, sheet thickness 3mm, base plate of size 200mmx220mmx12mm, foundation bolt 4xM20x600(Noxdiaxlength) with PCD 220mm,complete with in-built junction box with cable termination arragement, 3-core FRLS cable from J-box to light fitting, 1mtr long single arm brcket of hot dipped GI including necessary foundtion as per manufacturers design & specifications.
Supply and fixing cable route indicator made of mild steel plate of size 150mm x 150mm, 6mm thick fixed/welded on angle iron of size 25mm x 4mm , 600mm long, duly painted with one coat of primer of zinc oxide paint and finished with two coats of synthetic enamel paint and wirting of cable details as directed by Engineer-in-charge, grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates block of size 150 mm x150mm x150mm in foundation including necessary form work complete all as specified & directed. Note: PCC & formwork is deemed to be included in quoted rates.
S&F Change over switch 200 Amp, 4 pole, 415 V, 50Hz front operated with sheet metal enclosure duly fixed on 02 Nos angle iron 40x40x6mm, 1200mm long each complete with grouted in PCC as directed by Engr-in-Charge.
SEWAGE NETWORK & MANHOLES
S & F high-quality double wall corrugated polyethylene (DWCPE) (SN8) 150 mm diameter pipes with collar laid in trenches on concrete bed, jointed using sealing rings and coupler as per manufcturers instruction and as specified in IS; 16098 and IS: 14930 and tested complete all as specified and directed.
S & F high-quality double wall corrugated polyethylene (DWCPE) (SN8) 200 mm diameter pipes with collar laid in trenches on concrete bed, jointed using sealing rings and coupler as per manufcturers instruction and as specified in IS; 16098 and IS: 14930 and tested complete all as specified and directed.
S & F high-quality double wall corrugated polyethylene (DWCPE) (SN8) 250 mm diameter pipes with collar laid in trenches on concrete bed, jointed using sealing rings and coupler as per manufcturers instruction and as specified in IS; 16098 and IS: 14930 and tested complete all as specified and directed.
M & L for construction of circular Automatic flushing tank with syphonic action and of capacity 1300 Ltr all as specified CEAF/STD/230/2020 SH 1/1
M & L for construction of circular Automatic flushing tank with syphonic action and of capacity 1700 Ltr all as specified CEAF/STD/230/2020 SH 1/1
S&F for 100mm thick precast steel fibre reinforced concrete (SFRC), Heavy Duty (HD) manhole cover with frames of diameter 750 mm complying to the standard specifications as metioned in the IS 12592 BIS standard or as per manufactures instructions with minimum load bearing capacity 10-15 ton circular shape complete all as specified by Engr-in-Charge.
S&F for 100mm thick precast steel fibre reinforced concrete (SFRC), Heavy Duty (HD) manhole cover with frames of diameter 900 mm complying to the standard specifications as metioned in the IS 12592 BIS standard or as per manufactures instructions with minimum load bearing capacity 10-15 ton circular shape complete all as specified by Engr-in-Charge.
SCHEDULE `A' PART - XIII (MANNING & OPERATION) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Ist year manning & operation of 760 KLD STP complete with treated water distribution system and 100KVA rating DG set installed as per Sch 'A' of the work round the clock including Sunday & holidays in 3 shifts per day of duration 08 hours each as per timing to be decided by GE/Engr-in-Charge by deploying one operator and one helper per shift of the relevant trade.
2nd year manning & operation of 760 KLD STP complete with treated water distribution system and 100KVA rating DG set installed as per Sch 'A' of the work round the clock including Sunday & holidays in 3 shifts per day of duration 08 hours each as per timing to be decided by GE/Engr-in-Charge by deploying one operator and one helper per shift of the relevant trade.
3rd year manning & operation of 760 KLD STP complete with treated water distribution system and 100KVA rating DG set installed as per Sch 'A' of the work round the clock including Sunday & holidays in 3 shifts per day of duration 08 hours each as per timing to be decided by GE/Engr-in-Charge by deploying one operator and one helper per shift of the relevant trade.
Note for item srl no. 8.01 to 8.03(Manning & Operation):- (i) Operator shall be ITI qualified or with minimum 02 years working experience in operation of STP system of similar nature (iii) Records for daily & periodical checks as per OEM standards to be maintained by the contractor duly signed by operator & the concerned executives. Cost of stationary & equipment etc shall deemed to be inclusive in the quoted rates.(v) Life insurance, EPF, and ESI medical facilities of govt for all the personnel shall be done by the contractor and copy of the same to be submitted to the deptt.(vi) Minimum T&P and all safety material required for the operator to be provided by contractor. (vii) Any damages to the installed machinery during operation due to mishandling of the system shall be compesated by the contractor. (viii) Minimum wages to be paid by the contractor through nationalized bank ESC mode as per labour Laws. (ix) Weekly off as per labour act to be given to the operator & reliever to be provided by the contractor at no extra cost to the deptt. (x) Contractor to provide 02 pairs of overall combination with leather shoes to each operator and helper.(xi) In case of absentism of any operator in a shift , double the amount of shifts will be recovered from the contractor. (xii)Contractor shall obtain a affidavit from all operators & helper that they are deployed on temporary basis by the contractor for 11 months through outsourcing and they have no legal binding with department regarding employment/permanancy of job. Any court cases due to accident/break of jobs/compensation occuring due to laboure conflict during the contract period is to be delt by the contractor only. (xiii) Operators & helper will use their own conveyance to reach duty place.(xiv) Cost of consumable items required for operation of STP i.e. Chemicals for lab,Chlorine,polymer etc is deemed to be included in the quoted rates. (xv) During O&M period the housekeeping of the entire STP and related surrounding area is included in the scope of work. (xvi) During currency of M&O work manpower as specified in BOQ shall be deployed, in case of absent of manpower recovery will be made as per double the minimum wages applicable at the period of absent.
M/S RAJ KUMAR GUPTA
United Sales Corporation
M/s R. K. Bhambri
Hydrotech Paryavaran India Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .