Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance A 160 2ND FLOOR KRISHNA BHAWAN VIKAS MARG SHAKARPUR DELHI 110092 | DELHI | DELHI | DELHI | 110092 | -0.80% | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-RISL Fee as Rs 1000/- instead of 2000/- (required as per bid document) there for bid submitted by the bidder is not considerable (i.e. non - responsive) |
| 3 | Not Admitted-Fee/PreQual/Technical 34 SANGRAM COLONY MAHAVEER MARG C SCHEME JAIPUR JAIPUR RAJASTHAN 302001 UDYAM RJ 17 0032882 | JAIPUR | RAJASTHAN | 302001 | - | - | - | Not Admitted-Fee/PreQual/Technical Others-The earnest money & RISL Fees in budget head of tender fee, instead of depositing such fee in their respoctive budget heads. Hence, the bid submitted by the bidder is not considerable (i.e. non-responsive) |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical Non-Responsive |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
27 Feb 2026, 3:00 pmClosed
EXECUTIVE ENGINEER
THE EXECUTIVE ENGINEER P.W.D. ELECT. DIVISION, SECTT, Jaipur.
SITC of Boom barrier,Bollard integrated with wave reader RFID tap Reader in RLA, Jaipur.
2026_CEPWD_541097_1
EESectt_nit_32_25-26
Open Tender
Electrical Works
180 days
Electric work/EESECTT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
EESECTT/MDRISL
₹2.1 L
Yes
SUPERINTENDING ENGINEER, PWD, ELECTRICAL CIRCLE-II
13 Mar 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
25 Feb 2026
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required.
25 mm x 12 mm
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, modular 6 A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required
On board
Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required.
Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
3x 1.5 sq.mm
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size.
Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, Category 6A/Class Ea, U/FTP (Unshielded/Foiled Twisted Pair), 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, Shielded and Aluminum Foil Sheilding of Individual pairs protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies 500 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required.
Supply, Drawing and OLTS Testing, of OM2 Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.651 with outer sheath, cable should be used for LAN and WAN back bones, for indoor/outdoor installations these sheathed cable be placed in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.
6 fiber
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA powder coated, OM2 multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangeless/screwable adapters for SC/LC/SN/CS type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleeves, screws, nuts to install the panel for rackmount applications as per requirement. All as per pre approved by Engineer in charge.
Multi Mode LIU 6 Ports
Supply and erection of Mild steel Swaged tubular pole conforming to IS: 2713-1980 (part I to II) with base plate, The pole shall be made from steel tube & Pipe (IS:1141, Fe 410) including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32 mm dia. 'B' class GI cable sleeves. After erection pole shall be painted with two coat of red oxide primer and two coat of enamel paint of silver colour as per the direction of Engineer incharge complete as required of following height & designation. ( See Table P - 03 for specs. )
7.5 Mtr. ( 410 SP - 5 )
Add for supply and fixing of Pole OEM fabricated Mild steel Overhang of following size over the existing poles, Overhang shall be painted with two coat of red oxide primer and two coat of enamel paint of silver colour as required.
76.1 mm OD x 3.25 mm thickness
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
Single pole MCB (With B / C curve tripping characteristics)
6 A to 32 A rating
Double pole MCB (With B / C curve tripping characteristics)
40 A rating
Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.
Two pole 30 mA sensitivity
6A-32 A rating
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.
Glazed / Acrylic door (single phase) IK-09 and IP-43 with Metal end box
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required.
10 SWG tinned copper. Wire
Supply, Installation, Testing & Commissioning of 32 inch display work station having latest Intel® i7 processor, 16 GB RAM, 512 GB SSD, wireless Keyboard, wireless optical Mouse. Windows 11 Professional,All as per pre approved by Engineer in charge
Providing and Fixing of 8 port Layer 2 Network switch 10/100/1000 Base -T PoE port with 4X Gigabit RJ 45/SFP Combo port,Switcing capacity: 56 Gbps,Max. Packet Forwarding Rate: 41.7 Mpps,POE Budget: 193 W or Better complete in all respect.
SITC of 10KVA (3ph i/p & 1ph o/p ) of True Online Double Conversion Technology & Tower Rack Mounted UPS System with UPS should have Identical Isolation Transformer at UPS Input of same Make with Input Voltage Range 160V to 485 VAC based on load level with Input Frequency 40-70 Hz with 0.99 Power Factor at full linear load with Output Voltage 220/230/240V with Output Frequency 50/60 Hz +/- 0.1% along with THD v < 1 % for Linear Load ; < 3 % for Non Linear Load and output waveform should be pure sinewave with Upto 95 - 96% without Transformer loss with Overall Efficiency at rated load with UPS Panel Display Third Party NABL Accredited Test Lab Report (Not older than 4 years) and Valid PeP Certificate required of UPS Model Battery Bank for 30 mins 28AH x 28 No's SMF Batteries with Operating Temperature 0 to 40 Deg C without derating. All as per pre approved by Engineer in charge.
SITC of Bank of SMF Batteries having 28AHx 28 no’s. All as per pre approved by Engineer in charge.
SITC of Wave type biometric finger print scanner with maximum 100000 user storage capacity, 4 inch touch screen, should capture maximum 4 fingerprint in one sec, identification in less then or equal 2 sec, Wiegand in/out, door relay, 1 general purpose input, 1 general purpsoe output. Operating Temprature:- 0 C to 55 C, Certification:- CE, FCC, BIS, RoHS along with all required accessories etc. All as per pre approved by engineer-in charge.
SITC of 4 reader intelligent controller with on board LAN/Web server, 8 supervised Inputs and 4 nos. form-C relay outputs for easy and reliable interface with 3rd party systems, with 32-bit CPU to cater multiple readers, equipped with TCP/IP to sit on Lan network ,distributed intelligence, 32 MB Flash memory, Realtime clock,supports 128 card formats and 8 facility codes, 100,000 user and 100,000 transaction buffer, CE, UAE RoHS Listed along with all required accessories etc. All as per pre approved by engineer-in charge.
SITC of card Reader device with Supports over 15 common credential technologies & Contactless e-Purse Application Specification (CEPAS) credential compatibility, with WPC/BIS certified, EAL 5+ Certified Secure Element Hardware, along with all required accessories. All as per pre approved by engineer-in charge.
SITC of Access Control Software , Supporting minimum 512 online card readers, minimum 50 concurrent Clients/User, LDAP based and Application logon users, MS SQL Based, inbuild Guard Tour module, Elevator Control, various Reports with time stampping nearest to seconds, unlimited Timezones, various card attributes Supervisor, VIP, Escort, Custodian, integration with existing Fire Alarm System to free open/Lock designated door in case fire etc. complete as required . All as per pre approved by engineer-in charge.
SITC of Barcode/QR Code Scanner device based on VMS Client software, integration with existing software, along with all other accessories etc complete as required . All as per pre approved by engineer-in charge.
SITC of I/O controller for Barcode scanner along with all required accessories, etc. complete as required . All as per pre approved by engineer-in charge.
SITC of Barcode/QR Code Scanner Licenses per device, integration with existing software, installation charges on workstation, etc complete as required . All as per pre approved by engineer-in charge.
SITC of IP 54 rated Motorised Vehicle Barrier complete with Control Unit and integrated Loop Detector, telescopic /fixed arm Boom upto 6 mtr. , 0.6 sec to max 4 sec opening/closing time. All Housing and internal parts will be rust & corrosion free metals or alloys of high strength with suitable Epoxy coating. Modbus communication to integrate with Command control , LED Display, Operating ambient temperature up to -30°C +65°C., MCBF: 5-15 Million cycles, with remote , push button control, Modular expandable control system with adjustable speed, certification for ingresss protection from BIS/NABL etc complete in all respect along with all required accessories. All as per pre approved by engineer-in charge.
SITC of RFID Based Vehicle Access Control Software licenses, Alarm Count Weekly, Centralized Alarm Management, Emergency & Evacuation Management, Login Parameters: Using Employee ID as username, using email ID as username, enable or disable login lockout, Data protection and privacy standards: GDPR, SOC2 & VAPT, also capable of managing multifactor authentication for biometric readers also like finger only, finger + card, card only, finger or card., along with all required accessories, etc. Biometric Readers Integration Connector, Per Device Licence (along with Biometric Connector) etc complete in all respect along with all required accessories. All as per pre approved by engineer-in charge.
SITC of long range Radio Frequency Identification Device reader, reading distance upto 10 m, with operating frequency 850 to 950 mhz, IP-66 rating, as per EPC Gen 2 standards etc., shall comply with the protocol: EPC Gen 2, ISO 18000-6C, complete as required accessories at site and as per direction of Engineer-in-Charge.
SITC Linux-based open architecture Controllers for RFID reader, Ethernet 10/100 Mbps, TLS encryption, Certification of FIPS 140-2, FCC, CE, UL-294, RoHS, NIST Encryption, storage temp. from -55 to 85°C., transaction buffer upto 50000, along with all required accessories etc complete as required . All as per pre approved by engineer-in charge.
SITC of long range Radio Frequency Identification Device Tag (minimum 5mtrs.) for outdoor use for 2 wheeler, with operating frequency 850 - 900 mhz, IP-66 rating, as per EPC Gen 2 standards etc. complete as required and as per pre approved by engineer-in charge.
SITC of long range Radio Frequency Identification Device Tag (minimum 5mtrs.) for outdoor use windhsield with operating frequency 850 - 900 mhz, IP-66 rating, as per EPC Gen 2 standards etc. complete as required and as per pre approved by engineer-in charge.
Supply, Installation, Testing & Commissioning of 23.8 inch all in one computer having i5 processor 12th Gen, 16 GB RAM, 512 GB SSD, windows 11 pro, keyboard, mouse etc as per site requirement and as per pre approved by engineer-in charge.
SITC of Traffic Light with Traffic sensor with interconnected operation of boom barrier control unit etc all as per pre approved by engineer-in charge.
SITC of IP 68 Rating & High Resolution digital Area scan Under vehicle Scanning System made with 304 grade stainless steel along with required server, control box and ANPR Camera having various features i.e. load bearing capacity 40-60 tones (vehicle weight), area scan speed forward 0-100 km/h, backward 0-25 km/h, view angle > 180 degree for dual mode, black & white, colour image, resolution > 10000 x 4096 Pixels with ANPR camera having sensor 1/2.8 inch CMOS , 2 M P Range. The UVSS System shall be able to record the undercarriage images of vehicles in motion without requiring to be fully stopped and display these as a composite & high-resolution image on the monitor(s). The system should be able to take into consideration the different heights of the undercarriage (truck/car), widths and the lengths of the vehicles as they pass over the system. etc All as per pre approved by engineer-in charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.14 MB
Tendernotice_2.pdf
PDF • 0.41 MB
Tendernotice_3.pdf
PDF • 1.46 MB
Tendernotice_4.pdf
PDF • 0.61 MB
Tendernotice_5.pdf
PDF • 1.82 MB
Tendernotice_6.pdf
PDF • 0.62 MB
BOQ_964606.xls
BOQ • 0.28 MB
termsandconditions.pdf
Other Document • 0.24 MB
checklistboom.pdf
Other Document • 0.23 MB
compliancesheet.pdf
Other Document • 0.43 MB
Download all tender documents and submit your bid