| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.3 LAccepted-AOC | ₹80.3 L | L1 | Accepted-AOC lower the tender rate |
| 2 | Rejected-Technical | - | - | Rejected-Technical sl no 6 and not submitted |
| Sl No | Description | Qty | Unit | P.BASKARAN&CO L1 |
|---|---|---|---|---|
| 1.00 | Earth work excavating and deposting on bank with initial lead of 10m& intial lift of 2m in hard stiff clay, stiff black cotton, hard red earth shales ,murram, gravel, stoney earth mixed with small size boulders etc completed as per std specification. | 107 | M3 | 246 ₹26,322 |
| 2.00 | Plain Cement concrete of mix 1:4:8 (One part of cement, four part of sand and eight part of aggregates) using 40mm guage hard broken including cost conveyance of all materials to site and labour charges, transporting and placing in position including shoring, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification | 29 | M3 | 5,103 ₹1.5 L |
| 3.00 | Steel centering for sides and soffits including supports and strutting upto 1m height for plain surface such as RCC slab with all cross bracings using mild steel sheet of size 90cmx60cmx10 gauge stiffened with welded miled steel angles of size 25x25x6mm for laid over silver oak for coundary wood joints of size 10x6.5 cm spaced at about 90cm centre to centre and supported by casurials props of 10cm to 13 cm dia spaced at about 75cm centre to centre and suppor etc completed as per std specification.
Ground Floor & First Floor
A) Column | 197 | M2 | 919 ₹1.8 L |
| 4.00 | B) Grade beam | 229 | M2 | 459 ₹1.1 L |
| 5.00 | C) Lintel. Beam &slab | 635 | M2 | 505 ₹3.2 L |
| 6.00 | Supplying fabricating and placing in position of steel rods using TMT Steel ISI including cost of binding wire, cost of labour charges for fabrication and placing in position etc. Complete. Complying with std. specifications. | 12,300 | Kgs | 89 ₹10.9 L |
| 7.00 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - | 32 | M3 | 8,100 ₹2.6 L |
| 8.00 | Ground floor | 48 | M3 | 8,231 ₹4.0 L |
| 9.00 | First Floor | 43 | M3 | 8,491 ₹3.7 L |
| 10.00 | Brick Work in Cement Mortor 1:5 Mix (one part of cement and five part of sand) using II Class Bricks of size 9''X4 1/4''X2 3/4''from approved quarry including cost and conveyance of all materials to site loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.a) Upto Basement | 30 | M3 | 7,188 ₹2.2 L |
Tender Value
₹98 L
EMD Value
₹98,000
Closing Date
5 Jun 2025, 3:00 pmClosed
EXECUTIVE OFFICER
THIRUPORUR TOWN PANCHAYAT OFFICE OMR, THIRUPORUR
Construction of New Office Building SFNo276_1 In Thiruporur Village Thiruporur Town Panchayat.
2025_DTP_557199_1
151/2025
Open Tender
Civil Works - Buildings
THIRUPORUR TOWN PANCHAYAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹98,000
17 Jan 2026
13 May 2025
5 Jun 2025
13 May 2025
5 Jun 2025
13 May 2025
Amount
Earth work excavating and deposting on bank with initial lead of 10m& intial lift of 2m in hard stiff clay, stiff black cotton, hard red earth shales ,murram, gravel, stoney earth mixed with small size boulders etc completed as per std specification.
Plain Cement concrete of mix 1:4:8 (One part of cement, four part of sand and eight part of aggregates) using 40mm guage hard broken including cost conveyance of all materials to site and labour charges, transporting and placing in position including shoring, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification
Steel centering for sides and soffits including supports and strutting upto 1m height for plain surface such as RCC slab with all cross bracings using mild steel sheet of size 90cmx60cmx10 gauge stiffened with welded miled steel angles of size 25x25x6mm for laid over silver oak for coundary wood joints of size 10x6.5 cm spaced at about 90cm centre to centre and supported by casurials props of 10cm to 13 cm dia spaced at about 75cm centre to centre and suppor etc completed as per std specification. Ground Floor & First Floor A) Column
B) Grade beam
C) Lintel. Beam &slab
Supplying fabricating and placing in position of steel rods using TMT Steel ISI including cost of binding wire, cost of labour charges for fabrication and placing in position etc. Complete. Complying with std. specifications.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Ground floor
First Floor
Brick Work in Cement Mortor 1:5 Mix (one part of cement and five part of sand) using II Class Bricks of size 9''X4 1/4''X2 3/4''from approved quarry including cost and conveyance of all materials to site loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.a) Upto Basement
b) Ground Floor
c) First Floor
c) Second Floor
Collection Supply and Filling of well gravel from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and slacking the same to site to departmental gauge and filling to required depth, well rammed etc., Complete as per standard Specification
Plain Cement Concrete 1:2:4 Mix (one Part of cement, two Part of M- Sand and four Part of aggrigate) using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc., complete as per TNDSS NO: 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge.
Supplying and laying Precast Designer Paver Block confirming to IS 1568-2006 specification manufacturing and laying standard of M40 grade 83mm thick (table clauses 5 and 9.14) suitable for bus terminals ,industrial complexes, road on expensive soils etc., including the cost of paver block of size 225mm x 12.50 mm x 83mm and conveyance of materials to work site mentioned in the tender schedule cost of loading and unloading handling during over Stone dust of 100mm thick (excluding the cost of M- Sand) conveyance paver block cutter to site and hire charges of vibrators and block cutter operator and labour for leveling the M- Sand to paver block etc., complete ISI 15658-2006.
Special Ceiling Plastering in cement motor 1:3 mix (one part of cement and three part of sand) 10 mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc., complete as per standard Specification
Plastering in Cement Mortor 1:5 Mix (one part of cement and five part of sand) 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber system which provides high insulation properties with outerframe 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with allcorner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
Supply and Fixing of Teak wood scantling wrought and put up for frames of door and windows Complete as per standard specification.
Supply and fixing of Teak wood fully panelled and Double leaf (two Equal Panels) shutter for door including all labour charges cost and conveyance of all materials to site etc., Complete as per standard specification.
Supplying and fixing M.S.grill to doors, special windows and ventilators etc as directed by the departmental officers inclusive of cost of MS grill including one of cost red oxide and fixing in position etc., complete (as per the schedule of rate) SL.NO.182 Q3
Supply and fixing of U-PVC Two shuter openable Window using G.I steel Reinforcement, friction hinge, multipoint lock, and 5mm clear glass or foam sheet including cost and conveyance of all labour and all meterial charges etc Complete as per standard specification.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing in Position of indian type water closet with all set in brick jelly concrete 1:4:8 Mix concrete 10 cm thick using 20mm brick jelly and top finished with c.m. 1:3 mix 20mm thick without any leakage etc. Complete as per standard specification.
Supplying and fixing in position colour glazed EUROPEAN WATER CLOSET with 'P' or 'S' trap and double flapped seat cover, 12.50 litres capacity P.V.C. low level FLUSHING TANK including all internal fittings fixed on C.I. brackets, 12mm PVC or brass nipple, chromium plated brown headed stopcock, 12mm nylon connection with necessary teakwood plugs, clamps, screws to the portion coming with walls and floors, including dismantling masonry and redoing the same to the original condition.
Daddoing with glazed titles of size 305x200x6mm of approved make and quality and clour cement mortor 1:2, 10mm thick and pointing with white cement including finishing jointing and polishing with glossy finish etcComplete as per standard specification.
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Weathering course concrete with broken brick jelly of 20 mm gauge in pure slacked lime ( no sand to be added) over roof slab the proportion of brick jelly to lime being 32:12.5 by volume and laid over In a single layer and consolidated require designed and finished thickness by beating the concrete with wooden beaters of approved pattern , keeping the surface constantly with springing lime jiggery water asper standard specification and as directed by the departmental officers Complete as per standard specification.
Finishing with top of roof with one course of machine pressed tiles of size 23cmx23cmx2cm of approved quality laid in cement mortar 1:3 (One part of cement and three part of sand) 12mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with same water proofing compound mixed with cement motar ,red oxide, etc Complete as per standard specification.
Paving the floor with Erocone design tiles for flooring of approved make and quality and clour of in cement mortor 1:3 20mm thick and pointing with white cement including finishing jointing and polishing with glossy finish etc complete as per std specification
Painting the new walls two coats over one coat of priming with best weather proof Exterior Emulsion paint of approved colour and quality including preparation of surface and finishing neatly etc., complete complying with standard specification and as directed by departmental officers Complete as per standard specification.
Painting the new wood work in all floor two coat of best synthetic enamel paint of approved colour and brand over one coat of primer including scrapping and preparation of surface, cost of breshes and neat finishing complying with stadard specifications
Painting the new iron work in all floor two coat of best synthetic enamel paint of approved colour and brand over one coat of primer including scrapping and preparation of surface, cost of breshes and neat finishing complying with stadard specifications
Wiring with 2X1.5 sqmm (22/0.3) PVC insulated sc unsheathed Cu.conductor cable of 1100 V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with switch box with 5A F.T. switch(two way) in flush with wall and convered with 3mm thick hylem sheet for MS switch box with continous earth wire connection of 14 SWGTC wire and making good of the concealed portion with suitable colour for concealed stair case light point/Fan Point (SD.NO.24) Page No -13
Wiring with 2 x 1.5 sqm(22/0.3) insuheathed Sc Cu Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and celing with PVC accessories with TW switch box and 5A F.T switch in flush with wall 150 x 100 x 113 mm TW switch Box for 5A 3 pin non inter locking CS plug with continous earth wire connection of 14 SWG T.C wire and making good of the concealed portion with suitable colour for concealed PVC plug point (SD 36) Page No -20
Supply and fixing of TNEB meter board suitable for 32 A single phase service connection with 32A fues unit (500 V) 32A neutral link and earth link (1"X18" copper flat) on TW plant of size 375mm X 300mm X19 with supporiting TW reepers of 1 " thick an either side withpainting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wirefrom EB meter to fuse unit (SD No.125) Page No -51
Supply and run of 4 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 32mm G.I pipe (Class 'B' bent at both ends with necessary angle iron up right and end supports for mains (SD No.73) Page No -33
Supply and run of 4 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade on7/20 GI bearer wire for service connection mains (SD No.68)
Supply and fixing of Energy Efficient Ceiling Fan 1200 mm complete with stepped electronic 300 W regulator with 1 meter down rod on the existing clamp etc complete as per std sepcification.connection mains (SD No.107)
Supply and fixing of 3 phase 4 wire 4way ICDB of 32 Amps per way with 100 Amps TPN MC switch with suitable trunking box ms cable entry boxes and internal connection on suitable angle iron frame work with earth connection etc complete as per std specification.
Supply and delivery of 2000 litre capacity H.D.P.E.Water tank approved ISI Quality including cost and convenance of all materils to the site etc complete As per standard specification
Honeycomb brick work in cm 1:5 mix, using best country bricks including cost and conveyance of all materials to site and all other labour charges etc., Complete as per std Specifications.
Supply and Filling of 40 mm HBG ISS Metal from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and filling to required depth etc., Complete as per standard Specification (M-0086 Page 20 PWD SOR Volume 1 2024-25)
Wiring with 2x4sqmm (56/0.3mm) PVC insulated SC unsheathed Cu. Cable conductor cable of 1100V grade in suitable heavy gauge M.S.conduit pipe on wall and ceiling with M.S.accessories with 150mm x 100mm x 75mm MS switch box for 15A 3 pin non interlocking CS plug with painting of suitable colour,with continuous earthwire connection by 14 SWG TC wire for open power plug point. SD 13
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K. Lite) suitable for11W CFL lamp with CFL. SD 83
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. SD 88
Supply and delivery of following PVC Pipes 110mm PVC Pipe 6kg/cm2 including cost and conveyance of materials to site etc complete,.
Supply and Filling of 40 mm Brick Jelly from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and filling to required depth etc., Complete as per standard Specification
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf