| 1 | L1₹28.7 LAccepted-AOC 37 4TH CROSS ASHWATHNAGAR SANJYANAGAR POST BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.8 L+₹2.8 L (9.35%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.6 L+₹3.6 L (12.1%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹37.6 L+₹7.6 L (25.2%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.9 L+₹11.9 L (39.6%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
21 Jun 2024, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
REPAIR/REPLACEMENT OF FEEDER PILLAR BOX/BUSBAR CHAMBER/LT PANEL/EARTHINGS AND REPAIRS/REPLACEMENTS TO SECURITY LIGHTS/STREET LIGHTS/AREA LIGHTS/GATE LIGHTS,HIGH MAST AND CONTROLLING PANELS INCLUDING CONNECTING WORKS SMQ, OTM AND HQTC AREAS AT HQTC BA
2024_MES_655684_1
8215/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹88,000
31 Aug 2024
24 May 2024
29 Jun 2024
24 May 2024
21 Jun 2024
7 Jun 2024
25 May 2024 - 31 May 2024
Amount
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5m deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in,including spreading, levelling ,watering and well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&F sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed by Engineer-in-Charge. Note- Punned thickness of sand i.e 18 cm to be consider for measurement purpose.
Supplying and laying un-reinforced precast concrete cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation,filling and mass concrete in foundation of poles and stay assembly for bed concrete or as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation,filling and mass concrete in foundation of stay assembly and pole or as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in benching,coping including weathering slightly rounded or chamfered angles or as per site requirement with necessary plastering work complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable cable any type/size from trenches,pole, road,duct etc including necessary joints,U/S fittings and pipes etc complete all as specified and directed.
Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor of cross sectional area 10 sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
All as per item No-10.00 here-in-before but of size 10 sqmm 4 core.
All as per item No-10.00 here-in-before but of size 16 sqmm 4 core.
All as per item No-10.00 here-in-before but of size 16 sqmm 3 core.
All as per item No-10.00 here-in-before of size 25 sqmm 4 core.
All as per item No-10.00 here-in-before of size 35 sqmm 3.5core.
All as per itemNo-10.00 here-in-before of size 50 sqmm 3.5core.
All as per item No-10.00 here-in-before but of size 70 sqmm 3.5core.
All as per itemNo-10.00 here-in-before of size 95 sqmm 3.5core.
All as per item No-10.00 here-in-before of size 120 sqmm 3.5core.
Dismantling of unserviceable/damaged MCB/MCCB of any type/size and removal from site omplete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 63 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 125 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel / sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 4 poles 415 Volts, 400 Amps, 50 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 3 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 3 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, 3 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel /sheet metal enclosure/feeder pillar box or any place as directed including any addition, alteration in LT panel /sheet metal enclosure/feeder pillar box or in bus bar like drilling,cutting ,grinding or as per site requirement and connecting up incoming/out going cables connection with suitable size lugs and testing complete all as specified & directed by Engineer-in-Charge.
Dismantling and taking out old existing unserviceable/damaged/burnt change over switch 4 pole of capacity 63 Amp to 400 Amp 50 Hz 415 Volt any make,any capacity complete all as specified & directed by Engineer-in-Charge.
S&F in replacement on load Changeover switch in existing LT panel 415 Volt in sheet steel enclosure 4 pole of capacity 63 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement on load Changeover switch in existing LT panel 415 Volt in sheet steel enclosure 4 pole of capacity 100 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement on load Changeover switch in existing LT panel 415 Volt in sheet steel enclosure 4 pole of capacity 200 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement on load Changeover switch 415 Volt in sheet steel enclosure 4 pole of capacity 400 Amp including connecting up incoming/out going cables connection with suitable lugs and testing complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old rusted pipe and material and labour for 25 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 25x3mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old rusted pipe and material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 50x6mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
Dismantling of damaged/ rusted steel tabular poles any size and removal from sitecomplete all as specified & directed by Engineer-in-Charge.
Supply, installation and erection in replacement 9.0m long steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing confirming to IS-1161 part-II, type 410 SP -31 including drilling of holes of required size and nos for fixing of cross arms/clamps, poles shall be painted internally throughout using anti corrosive black bituminous paint and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete,painting three alternating layer of each black and yellow paints at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge. Note:- Any wire, any type cable, any type box, CCTV camera, any type street light fitting, poster,picture or any items fixed with pole shall be taken down carefully and safely and refixed to the new steel pole in same position in quoted rates.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board,LT panel etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified & directed by Engineer-in-Charge. Note- The unit rate includes main earthing lead GI earth strip of size 32x6 mm with 40 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 mtr and necessary earth work excavation returning filling etc required for earth pit.
S&F GI strip 32 x 6 mm with saddles and fixing screws on porcelein insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building/ connect to LT panel or main DB and joining the same with existing earth test point all complete all as specified & directed by Engineer-in-Charge.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as specified & directed by Engineer-in-Charge.
M&L Cable jointing kit Straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 6 sqmm to 16 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L Cable jointing kit Straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 25 sqmm to 50 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L Cable jointing kit Straight through joints heat shrink type for XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable 1100V grade with aluminum conductor cables of size 70 sqmm to 120 sqmm by excavating earth, identifying the fault, making proper joint of cable,testing of cable after rectification & returning soil back to earth complete all as specified & directed by Engineer-in-Charge.
M&L Scrapping and removing of existing paint,dust,rust by emery paper or other means and preparation of smooth surface for painting and painting with two coat of high quality synthetic enamel paint with approved colour on any size ,any type and any capacity feeder pillar box, LT panel including writting of incoming and outgoing location of all cables on LT panels and feder pillar boxs with high quality synthetic enamel paint red colour complete all as specified & directed by Engineer-in-Charge.
Supply and fixing in replacement Digital type ammeter of range 0-600 Amp Accuracy Class 1.0 of LT panel with all connected accessories including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Digital type Voltmeter of range 0-500 Volts Accuracy Class 1.0 of LT panel with all connected accessories including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement LED indicator lamp 240 V set of three (R,Y,B) of LT panel with all connected accessories including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Curent transformer (CT) 300/5A , accuracy class 1.0 , burden 10 VA , resin cast wound type of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Curent transformer (CT) 250/5A , accuracy class 1.0 , burden 10 VA, resin cast wound type of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Curent transformer 100/5A , accuracy class 1.0 , burden 5 VA , resin cast wound type of LT panel including connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Power factor capacitors metalized poly propylene heavy duty MPPH type for 3 phase 440V , 50 Hz system of 10 KVA rating fixing in existing position capacitor including taking down unserviceable capacitor and connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Power factor capacitors metalized poly propylene heavy duty MPPH type for 3 phase 440V , 50 Hz system of 20 KVA rating fixing in existing position capacitor including taking down unserviceable capacitor and connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Power factor capacitors metalized poly propylene heavy duty MPPH type for 3 phase 440V , 50 Hz system of 25 KVA rating fixing in existing position capacitor including taking down unserviceable capacitor and connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F in replacement Power factor capacitors metalized poly propylene heavy duty MPPH type for 3 phase 440V , 50 Hz system of 50 KVA rating fixing in existing position capacitor including taking down unserviceable capacitor and connecting up and testing complete all as specified & directed by Engineer-in-Charge.
S&F 3 pole Power contactor MNX type AC, 415V, 50Hz 3 MNX 95 Contactor 2 NO+ 2 NC including taking down unserviceable and connecting up ,testing complete all as specified & directed by Engineer-in-Charge. Make - L&T CS94136 or equivalent in Legrand, Schneider or Havells.
S & F 3 pole Power contactor MNX type AC, 415V, 50Hz 3 MNX 110 Contactor 2 NO+ 2 NC including taking down unserviceable and connecting up ,testing complete all as specified & directed by Engineer-in-Charge. Make - L&T CS94137 equivalent in Legrand, Schneider or Havells.
S & F 3 pole Power contactor MNX type AC, 415V, 50Hz 3 MNX 140 Contactor 2 NO+ 2 NC including taking down unserviceable and connecting up ,testing complete all as specified & directed by Engineer-in-Charge. Make - L&T CS94138 equivalent in Legrand, Schneider or Havells.
M&L Loose filling with aggregates of gauge 40 mm filling in Panel surrounding area as per ground availability of area, cleaning the area, removing vegitation,debris around panel upto 2 mtr radius making level, and filling the aggregate upto 100 mm height complete all as specified & directed by Engineer-in-Charge.
Supply, installation,commisioning and testing Weather proof busbar chamber 600x450x300MM made out of 2 MM thick CRCA steel sheet & 40x5 MM angle iron frame suitable for mounting 1 mtr above ground level with locking arrangements incl. Provn of 4 Nos aluminium busbar of 600 Amps rating mounted on insulated frames 2 Nos incl. connecting up incoming & outgoing cables complete with glands,lugs incl.painted with two coats of powder coated paint over a coat of red oxide primer, including necessary PCC 1:3:6 type C1 in foundation for mounting complete all as specified & directed by Engineer-in-Charge.
Supply, installation,commisioning and testing out door type LT Panel made out of mild steel CRCA sheet of 3.15 mm thick with angle iron frame of size 50mm x 50mm x 6mm with canopy top,two side ventilators,front openable hinged, double door shutters with locking arrangement (including lock & key), weather & vermin proof suitable for operation on 440 volts, 50Hz, 3 Phase 4 wire AC supply including bus bar chamber and aluminium bus bar of 630 Amps 4 nos mounted on hygroscopic insulators,all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces and providing necessary foundation/plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories.
Incoming:- (a) MCCB 4 Pole,500 Amps, 415 volt of breaking capacity not less than 36 KA -1 No . (b ) Digital type ammeter composite type with suitable CT, 0-500 amps -1 No. (c ) Indicator lamp LED type set of three(R,Y,B) - 1 No (d) Digital type Voltmeter composite type with ,0-500 Volts -1 No. Outgoing:- (a) MCCB 4 Pole,125 Amps, 415 volt of breaking capacity not less than 35 KA -4Nos. (b) MCCB 4 Pole,63 Amps, 415 volt of breaking capacity not less than 25 KA-2 Nos .
Taking down existing defective/unservicable street light fittings/security light fittings/Flood light fittings of any capacity,any description,any wattage, any typeand in any position from poles/pipes/ walls of buildings of any height complete after disconnecting the electrical connection replacement of un-serviceable/damaged/ broken spare parts/ brackets etc, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in same position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge.
Taking down existing defective/unservicable post top lanterns/Gate lights /Garden lights fitting of any capacity,any description,any wattage, any type and in any position fixed at a height not more than 4 mtr from ground level complete after disconnecting the electrical connection replacement of un-serviceable/damaged/ broken spare parts,accessories etc, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in same position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge.
Lowering of and lifting of carriage of high mast lights fitting with wire rope motorised or manually existing defective/unservicable high mast lights fittings of any capacity,any description,any wattage, any type,any position and any height after disconnecting the electrical connection replacement of un-serviceable/damaged/ broken spare parts/ accessories etc,including servicing of High mast of any height and description , opening the mechanical hoisting / lowering assy , steel wire bobbin , replaceing the unservieable meshing gear, easying the steel rope movements, checking the locking mechanism , replaceing of oil ,greasing complete and checking for smoothing operation of the mast, re-assembling the high mast lights fittings and making the high mast lights fittings serviceable, fixing the fittings in same position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge.
S&F high energy efficent constant current electronic driver suitable for LED street light fitting 35 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
S&F high energy efficent constant current electronic driver suitable for LED street light fitting 45 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
S&F high energy efficent constant current electronic driver suitable for LED street light fitting 90 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
S&F high energy efficent constant current electronic driver suitable for LED street light fitting/ Flood light fitting 100 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
Supply and fixing high energy efficent constant current electronic driver suitable for LED Flood light fitting 30 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
Supply and fixing high energy efficent constant current electronic driver suitable for LED Flood light fitting 50 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
S&F high energy efficent constant current electronic driver suitable for LED Flood light fitting 60 Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
S&F high energy efficent constant current electronic driver suitable for LED Flood light fitting 200Watts, LED luminaires 240 Volt ,50Hz, AC single phase complete all as specified and directed by Engineer-in-Charge.
M&L for opening the LED street light/Flood light fittings of capacity 30 watts to 60 watts ,any type and in any position,taking out the LED motherbaord,checking the power LED's, replaceing the unserviceable motherboard,electronic driver, power LED's and soldering or any item as per requirement and making the light fittings serviceable in any way and fixing the fittings in same position including testing, complete all as specified and directed by Engineer-in-Charge.
M&L for opening the LED street light/Flood light fittings of capacity 90 watts to 200 watts ,any type and in any position,taking out the LED motherbaord,checking the power LED's, replaceing the unserviceable motherboard,electronic driver, power LED's and soldering or any item as per requirement and making the light fittings serviceable in any way and fixing the fittings in same position including testing, complete all as specified and directed by Engineer-in-Charge.
Dismantling the three phase motor upto 5 HP,440 Volt ,50Hz, AC of High mast lights fittings and taking out to workshop for rewinding,removing the burntout windings, rewinding the same with super enamelled copper wire of existing guage,varnishing and oven drying , and replacing any item as per requirement ,assembling the motor including testing, making the motor serviceable in any way and fixing the motor in same position complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out old rusted/ unserviceable light fitting’s bracket incl FI clamps of any description and in any position and supplying and fixing brackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing of street light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washers complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out old rusted pipe and material and labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including Flat Iron clamps=02 Nos of size 30x5mm, with nut bolt and washers complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old existing unserviceable PVC cable loop box and supplying and fixing with pole PVC cable loop box, size not less than 200 mm x 140 mm x 95 mm, out door type, IP 65 including 4 Nos aluminum bus bar of size 25mmx5mm mounted on porcelain insulators with one MCB SP 6 amps 230 volts connected to street light fitting sub main wire and using FI clampsof size 20mm x3 mm for fixing of PVC cable loop box with pole,including nuts,bolts & washers and connecting the cables to bus bars with using suitable size GI nut, bolts and washers and aluminum lugs etc and complete all as specified & directed by Engineer-in-Charge.
Disconnecting and taking out old existing unserviceable PVC cable loop box and supplying and fixing with pole PVC cable loop box, size not less than 145 mm x 145 mm x 95 mm, out door type, IP 65 including porcelain insulated connectors for incoming and outgoing 4 core cables with one MCB SP 6 amps 230 volts connected to street light fitting sub main wire and using FI clamps of size 20mm x3 mm for fixing of PVC cable loop box with pole,including nuts,bolts & washers and connecting the cables to connectors with using suitable size GI nut, bolts and washers and aluminum lugs etc and complete all as specified & directed by Engineer-in-Charge.
M&L Sub main wiring from street light fitting to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 1.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed by Engineer-in-Charge. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
S&F single core PVC insulated FR cable with multistranded copper conductor of size 2.5 sq.mm cross sectional area, 1100 Volts grade, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP, 6-32A, 240V,50Hz ,10kA, 'B' type, for street light fittings complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 32A, 240V,50Hz ,10kA, 'B' type,suitable for existing timer control board complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN,63A, 415V,50Hz ,10kA, 'B' type,suitable for existing timer control board complete all as specified and directed by Engineer-in-Charge.
S&F 3 pole Power Contactors 415 volt 50 Hz ML3 type 40 Amps AC3 rating with 2 NO +2NC Aux contacts, fixed in repairs,including taking out old existing unserviceable complete all as specified & directed by Engineer-in-Charge. Make : L&T Cat No. SS 90721 or techno commercially equivalent in Legrand, Schneider or Havells.
S&F 3 pole Power Contactors 415 volt 50 Hz ML 4 type 70 Amps AC3 rating with 2 NO +2NC Aux contacts, fixed in repairs,including taking out old existing unserviceable complete all as specified & directed by Engineer-in-Charge. Make : L&T Cat No. SS 90910 or techno commercially equivalent in Legrand, Schneider or Havells.
S&F Digital Multi function time switch with programmable fuction with battery backup and current carring capacity 16 Amps with 1 changeover including takingout the unserviceable time switch, complete all as specified & directed by Engineer-in-Charge. Make L&T 67DDT0 or techno commercially equivalent in Legrand, Schneider or Havells.
S&F Street light panel box 32 Amps , 3 pole, 230 volts with contactor, Digital time switch ,24 hours timer , MCB TPN etc, including takingout the unserviceable street light panel box , complete all as specified & directed by Engineer-in-Charge. Make Indo Asian TL032DBO or techno commercially equivalent in Havells, L&T or Schneider.
S&F LED flood light fitting 30 watts,240 Volt, single phase, AC, outdoor type,aluminium pressure die-cast housing with IP66 protection with 4 Kv in-built surge protection complete with driver,motherboard and LED including taking down unserviceable fitting, connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj BJFL 30W LED or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED flood light fitting 50 watts,240 Volt, single phase, AC, outdoor type,aluminium pressure die-cast housing with IP66 protection with 4 Kv in-built surge protection complete with driver,motherboard and LED including taking down unserviceable fitting, connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj BJFL 50W LED or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED flood light fitting 60 watts,240 Volt, single phase, AC, outdoor type,aluminium pressure die-cast housing with IP66 protection with 4 Kv in-built surge protection complete with driver,motherboard and LED including taking down unserviceable fitting, connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Havells JETAALBAFLOODLIGHT60W or techno commercially equivalent in /Philips/Wipro.
S&F LED flood light fitting 100 watts,240 Volt, single phase, AC, outdoor type, with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj PRAZE F 120L WH NB-A5 TG SD or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED flood light fitting 200 watts,240 Volt, single phase, AC, outdoor type, with superior polycarbonate optics pressure die-cast housing, with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj GLEAM F 220L WH SY PC SD V2 or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED street light fitting 35 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing with IP66 protection,high performance polycarbonate optics, 4 Kv in-built surge protection with top opening driver cover complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed by Engineer-in-Charge.Make Bajaj ENXT P 42L WH PO PC SD MT or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED street light fitting 45 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing with IP66 protection,high performance polycarbonate optics, 4 Kv in-built surge protection with top opening driver cover complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj ENXT P 54L WH PO PC SD MT or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED street light fitting 90 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj ZELA P 108 L WH PO TG SD or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED street light fitting 100 watts,240 Volt, single phase, AC, outdoor type with pressure die-cast housing, toughened glass with IP66 protection with 4 Kv in-built and 10 Kv external surge protection complete with driver,motherboard and LED including taking down unserviceable fitting,connecting and testing complete all as specified & directed by Engineer-in-Charge. Make Bajaj ZELA P 120 L WH PO TG SD or techno commercially equivalent in Havells/Philips/Wipro.
S&F LED post-top light fitting 25 watts made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP 65 protection with 25 watt LED bulb including taking down unserviceable fitting, complete all as specified & directed by Engineer-in-Charge. Make Bajaj BGCTN 25 W LED WH or techno commercially equivalent make of Havells,CG.
S&F LED post-top light fitting 25 watts made in spherical shape polycarbonate opal and clear diffuser with IP 65/66 protection with 25 watt LED bulb including taking down unserviceable fitting, complete all as specified & directed by Engineer-in-Charge. Make Bajaj BLPTSP 25 W WW LED or techno commercially equivalent make of Havells,CG.
S&F LED Bulbs 20 Watts, BEE star rated energy efficient Retrofit bulb, including taking down unserviceable lamp, complete all as specified & directed by Engineer-in-Charge. Make - Havells, Bajaj, Philips,CG.
S&F LED Bulbs 9 Watts, BEE star rated energy efficient Retrofit bulb, including taking down unserviceable lamp, complete all as specified & directed by Engineer-in-Charge. Make - Havells, Bajaj, Philips,CG.
S&F Battery box suitable size as per existing sample fixed at site made out of 2mm thick CRCA steel sheet suitable for solar street light fitting tubular lead acid photovoltaic battery 12V, 45Ah with locking arrangement (including lock & key) with two coats of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
S&F in replacement tubular lead acid photovoltaic battery 12V, 45Ah, for solar street light fitting complete all as specified & directed by Engineer-in-Charge.
M/s BHOOMI ELECTRICALS
M/s STAR ELECTRICALS
ARUNOTHAYA TRADERS
RRK PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .