Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Quoting Lowest Rate | |
| 2 | L2₹15.7 L+₹14,000 (0.90%)Rejected-Finance | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹15.9 L+₹32,430 (2.08%)Rejected-Finance | L3 | Rejected-Finance Quoting Higher Rate |
| Sl No | Description | Qty | Unit | P.S.Enterprise L2 | Hipotronics Engineers L3 | IRP Enterprise L1 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of UPS incl. battery bank of 30 KVA 28800 VAH ( SMF Battery) 12 Volt 3ph input /3ph output inbuilt isolation transformer , static by pass arrangement, compitable with D.G. Set , DSP controlled IGBT based rectifire with 90% efficincy on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form Pure Sine wave. It Should be operated 50˚ c above ambient temprature built in solid state float cum boost charger with autimatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load /Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage/ under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low,Static by-pass ON, Over temperature. Battery set Complete with self
standing cubicle or cabinet. The UPS battery shall be of Advanced Glass Mat Valve | 2 | Item | 7,86,000 ₹15,72,000 | 7,95,215 ₹15,90,430 | 7,79,000 ₹15,58,000 Lowest |
| 1.01Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant Rating, 28800 VAH (12V, SMF Battery).Amavraya Quntra/ Exide Power Safe. Power Safe. Back up time : 30 Min at full load.Warranty : One Year on UPS and two Years on SMF Battery on site against any manufacturing defects.Certificate:ISO 9001:2015,ISO 14001:2015,IOS 18001,OHSAS 18001.CE Certification: IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950(Safety),IEC/EN 50091-2,IEC/EN 62040-2(EMC Emmission), IEC/EN 62040-3(Performance &Design),IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146(Design & Manufacture) Make: APC/NUMERIC/Power One/Avo | ||||||
| 1.02standing cubicle or cabinet. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant Rating: 30 KVA, 3ph input / Output Capacity: 28800 VAH(12V, SMF Battery).Amarraja Quntra/ Exide Power Safe. . Back up time : 30 Min at full load. Warranty : One Year on UPS and two Years on SMF Battery on site against any manufacturing defects.Certificate:ISO 9001:2015,ISO 14001:2015,IOS 18001,OHSAS 18001.CE Certification: IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950(Safety),IEC/EN 50091-2,IEC/EN 62040-2(EMC Emmission), IEC/EN 62040-3(Performance &Design),IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146(Design & Manufacture) Make: APC/NUMERIC/Power One / Switching Avo / Vertiv / Dell | ||||||
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
21 Nov 2023, 3:00 pmClosed
Superintendent Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Electrical Installation work for proposed Level II Trauma Center at Anamoy SSWH Second Campus of BMCH in the Dist. of Purba Bardhaman (Electrical Work) 3. SITC of UPS
2023_WBPWD_598539_1
WBPWD/SEWEC /BED /NIQ-125 /2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Purba Bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,000
Office of the Superintending Engineer, Western Ele
29 Jul 2026
2 Nov 2023
23 Nov 2023
2 Nov 2023
21 Nov 2023
7 Nov 2023
2 Nov 2023 - 6 Nov 2023
6 Nov 2023
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .