Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.3 Cr+₹19.8 L (17.8%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.3 Cr+₹19.8 L (17.8%) | L-2 | Rejected-Finance other than L-1 |
| 3 | L-3₹1.3 Cr+₹21.7 L (19.5%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | ₹1.3 Cr+₹21.7 L (19.5%) | L-3 | Rejected-Finance other than L-1 |
| 4 | L-4₹1.3 Cr+₹24.0 L (21.7%)Rejected-Finance | ₹1.3 Cr+₹24.0 L (21.7%) | L-4 | Rejected-Finance other than L-1 |
| 5 | L-5₹1.4 Cr+₹27.0 L (24.3%)Rejected-Finance SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.4 Cr+₹27.0 L (24.3%) | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
14 Aug 2021, 6:00 pmClosed
SHRI DIGVIJAY CHAUHAN
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
Spl repair/ replacement of centralised air conditioning system in bldg No P-04 underground OPs room of HQ (NC) under GE (Utility) Udhampur
2021_MES_459581_1
CWE/U(U)-25/2021-22
Open Tender
Miscellaneous Works
Item Rate
240 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (Utility) Udhampur
₹2.1 L
Yes
11 Sept 2021
14 Jul 2021
21 Aug 2021
14 Jul 2021
14 Aug 2021
30 Jul 2021
Amount
Taking down / Dismantling of the existing plant completely comprising of compressor, slipring motor, chiller, Condenser, ducting , AHUs, pipe lines, chiller/condenser pumps, liquid line, control valves, cooling tower, control panel etc and making good the surface all as specified and directed depositing in MES store yard
Installation, testing and commissioning of microprocessor controller chilled water type central air conditioning plant of capacity 50 TR x 3 Nos (2x50 TR working + 1x50 TR stand by) for building No. P-03,P-04 & P-06 Under Ground Ops room to maintain inside room temperature 24°C + 2°C DBT & RH not exeeding 55% and dust filtration level 99.9% down to 5 micron ( E U 5 filters). (Note: Items required to complete the plant shall be measured separtely in respective items of schedule of the BOQ specified here-in-after). The unit shall comprising the following :-
CHILLING UNIT Water cooled twin scroll chilling Unit complete factory assembled & factory tested of 50TR actual capacity working on 407C eco friendly Freon gas comprising of scroll compressors with motors suitable for 415v, 50HZ,3Phase AC supply ,water motors cooled condenser, evaporator, refrigerant piping, control & accessories, starter and microprocessor, control panel, refrigerant & oil charged, mounted on common base frame with anti vibration pads & complete as per specification ( 2 Nos x 50 TR Working,1 No. x 50TR Standby) : (03 Nos) comprising following:- (a) Capacity of chilling machine :50TR (b) Condenser water temp.in ; 90 Deg.F (c) Condenser water temp.Out ; 97.5 Deg.F (d) Chilled water temp.in 53Deg.F (e) Chilled water temp.out 45Deg.F (f) Condenser fouling factor :0.001 (FPS). (g) Chiller fouling factor :0.0005 (FPS).
CONDENSER WATER CIRCULATION SYSTEM COMPRISING OF : (a) FRP induced draft cooling tower of 100TR capacity complete with spray section, honey comb fill basin, fan, TEFC motor, intake bird screen and other accessories (Tech Specification as per manufacturers standard and will be submitted to department before placing order) and shall be located at GF within five meter distance from plant room.: 01 No (b) PVC/HDPE tank of 5000 litre capacity on existing PCC/brick staging mounting upto 5 mtr height for make -up water requirement including brass float valve with polyethylene ball, over flow and drain arrangement. Incoming connection to be provided by Deptt. and complete all as specified & directed by Engineer-in -Charge : 01 No (c) 1 No. Expansion tank of 1000 litre capacity made out of 3mm thick MS sheet including connection & insulation with 50mm thick fiber glass / thermocole finished with 10 mm thick cement plaster(1:4)
Serial item No. 4 Contd........ (d) Centrifugal monoblock type pumping type set of 100% capacity with bronze impeller , complete with suitable squirrel cage induction motor of 10 HP suitable for operation at 415V, 3 phase ,50HZ AC supply , flow rate 1500 LPM , Head upto 25 mtrs including anti vibration rubber pads with suitable starter with overload protector ,protector against phase reversible and single phase preventor and 02 NOs of dial type 150mm dia water pressure gauge and temp gauge all as specified as per manufacturer recommendation. (One working & one Standby) ( 2 Nos) (e) Non-chemical type scale preventer of suitable size : 1No.
CHILLED WATER CIRCULATION SYSTEM COMPRISING OF Centrifugal monoblock type pumping type set of 100% capacity with bronze impeller , complete with suitable squirrel cage induction motor of 10 HP suitable for operation at 415V, 3 phase ,50HZ AC supply , flow rate 1500 LPM , Head upto 25 mtrs including anti vibration rubber pads with suitable starter with overload protector ,protector against phase reversible and single phase preventer and 02 NOs of dial type 150mm dia water pressure gauge and temp guage all as specified as per manufacturer recommendations. . (One working & one Standby) ( 2 Nos)
WINTER HEATING SYSTEM COMPRISING :- (a) 1No Hot Water Generator of capacity 54KW complete with heaters, electrical control panel with contactors, wiring & controls, thermostats and insulation as per specification:- (i) Heating capacity 54kw. (ii) Water in Temp 110 Deg F (III) Water out Temp 125 Deg F (b) Centrifugal monoblock type pumping type set of 100% capacity with bronze impeller , complete with suitable squirrel cage induction motor of 10 HP suitable for operation at 415V, 3 phase ,50HZ AC supply , flow rate 1500 LPM Head upto 25 mtrs including anti vibration rubber pads with suitable starter with overload protector ,protector against phase reversible and single phase preventer and 02 NOs of dial type 150mm dia water pressure gauge and temp guage all as specified as per manufacturer recommendations. . (One working & one Standby) ( 2 Nos)
CHILLED WATER PIPING (EXPOSED) Supply,Farication,Erection,Testing and Commissioning of MS pipes- C Class conforming to IS: 1239/3589 heavy class including all fittings like couplings ,bends ,elbow, tees etc. Piping shall be supported with frame structure, necessary hardware's Clevis support i.e U strap clamp etc . thrust blocks of rubber material having density 1400kg / cum insulation shall be with two half round section of PUF ( Polyurethane ) in density 36±2 Kg /cum conforming to IS :12436. Section shall be bonded to the surface of pipe with adhesive fevicol SR 998 and binded with metal binding wire, apply fevicol AC Duct Lag Coating AF : 5590 on insulated surface uniformly and wrap the Glass Cloth tightly with over lapping so that no gaps are left and no air pockets are formed. Immediately apply additional coating as a final finish layer on wrap cloth with necessary hardware fitting for following pipe size:-
Pipe NB 100mm with insulation thickness 60mm
Pipe NB 80mm with insulation thickness 55mm
CONDENSATE DRAIN PIPING:- Supply and laying Fabrication ,Erection ,Testing and Commissioning of MS pipes -C class conforming to IS : 1239/3589 heavy class including all fittings like anchor fasteners, Pipe supporting steel frame structure, coupling, bends , elbows, tees, thrust blocks, rigid polyurethane foam block etc . Insulation shall be with two half round sections of PUF ( Polyurethane) in density 36±2 Kg /m3 conforming to IS :12436. Section shall be bonded to the surface of pipe with adhesive fevicol SR 998 and binded with metal binding wire, apply fevicol AC Duct Lag Coating AF : 5590. Apply Final layer for following pipe size:-
Pipe NB 40mm with insulation thickness 60mm
Pipe NB 32mm with insulation thickness 55mm
CONDENSER WATER PIPING Supply and laying ,Fabrication ,Erection ,Testing and Commissioning of MS pipes -C class conforming to IS : 1239/3589 heavy class including all fittings like coupling ,bends,elbows,tees etc Piping shall be supported with steel frame structure,necessary hardware's, Clevis support i.e U strap clamps etc , thrust blocks of rubber material having density 1400kg/cum for following size pipe:-
150mm dia
100mm dia
80mm dia
M & L for Primary Supports for Ducts with Gripple Wire Primary Supports. Supply , Installation of Primary Supports as per following specification:- (i) M S Hollow Square Pipe length and Height shall be suitable to loop Gripple Wire. (ii) M S Plate to support the primary supporting system from Purlin / Truss level. (iii) The support shall be painted as per standard color code. (iv) AC Ducts supported and hangers as per specification for Size of M.S . Hollow Square Pipe in mm : 50x50x5 , dia of Hanger Rod of 15mm with lock bolt and other standard , Size of M.S . Hollow Square Pipe in mm : 25x25x3 accessories. Note all Material required for fabrciation of Duct of any size/shape will be deemed in this quoted rate.
AIR TREATMENT SYSTEM COMPRISING OF THE FOLLOWING S & F of Air Handling Units OF CAPCITY 25000CFM,55MM SP,70TR Sectionalzed construction double skin air handling uint fabricated out of 0.6mm thick pre- coated GI sheet outer skin and 0.6mm plain GI sheet inner skin with 25mm thick PUF of density 38kg/cum injected in between the panels. The AHU shall comprise of fan section with DIDW forward curved blower coil section with cooling coil, heating coil, pre- filter section with synthetic type pre-filter section with synthetic type fine filters having efficiency 97% down to 5microns, and squirrel cage induction motor of adequate rating Control for AHU comprising of three way mixing valve with modulating motor ,proportionate thermostat, heating thermostat and humidistat and humidity control system comprising plumbing works PVC water tank (100 litres capacity) spray nozzles, heaters for dehumidification and humidifying pump) and civil work comprising of PCC foundation for AHU, making opening in brick wall and making good for ducts, pipes, cable and fresh air intake all as specified and directed.
Description all as per above item but 5000CFM, 55MMSP,15TR (One No. AHU to installed at a distance of 60 meters (Approx) from the plant room).
Supply and fix air ducting made out of commercial grade GI Sheet (Zinc coating 120 gm /Sqm) and fabricated as per IS-655.First five meter of the duct will be acoustically insulated with 25mm thick fiber glass wood (density 24kg/Cum) and 28 SWG Aluminium perforated sheet.Ducting wherever passing through unconditioned space only shall be insulated with resin boned mineral /glass wool 50mm thick (density 24 kg /Cum). Aluminium foil (0.05mm) faced and fixed with PVC tapes shall be passing through condition space /return air space. Outdoor insulation shall be finished with 10 mm thick 1:4 Cement and sand plaster Attic space present in the corridor shall be used for return air path. Any boxing /false ceiling /partition required for RA passage through the corridor/lobby/rooms shall be provided by the deptt / other agency. No volume control damper shall be provided in the ducting as the flow of air shall be controlled by the VCD damper installed in SA grills comprising following:- (a) Aluminium anodised grills /diffusers complete with MS volume control for supply air grills /diffusers.
Serial item No 14 Contd… (b) Fresh air intake. (d) Fusible link operated (UL stamped) fire damper made out of 16 SWG GI / CRCA sheet to be provided in main supply air duct. (e) Detail drawings of plant layout, ducts, electrical system, fire dampers etc will be submitted by the bidder within five (05) weeks of acceptance of the tender for the approval of the GE. Note : Diffusers/Damper/Grills shall be included in above unit quoted rate.
Supply and laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area with suitable dressing material of the following size:-
Cross-sectional area 120 Sq.mm, 3.5 core . (from Main LT Panel to Microprocessor based AHU Control Panel)
Cross-sectional area 95 Sq.mm, 3.5 core (from Main LT Panel to chiller)
Cross-sectional area 35Sq.mm, 4 core (from Main LT Panel to Microprocessor based AHU Control Panel)
Supply and laying of PVC insulated 4 Sq.mm 3.5 core , armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional areawith suitable dressing material (from Microprocossor based AHU Control Panel to AHU Fan Drive Motor)
Note for serial item No 2 to 16 (i) All civil work require such as PCC foundation for chilling units, pumping sets ,cooling tower ,Make-up water tank, AHU and making opening in brick wall and making good for ducts,pipes,cable and fresh air intake shall be deem included in unit quoted rates. (ii) The complete AC plant unit shall have compressor mounting arrangement on rubber Grommets with metal sleeves. Water cooled shell & tube type condenser. Flooded type evaporator duly insulated. Thermostat expansion valve with Extl.Equalizer.Unit shall have filter dryer, pressure switch i.e HP/LP, Electronic thermostat, flow switch at achiller, integral refrigerant piping & wiring, accessories as required and called for , Automatic and safety control mounted in central console electronic microprosser, with internal overload protector facilities complete all as specified are directed with AC plant comprising and using 407C eco friendly Freon gas (iii) Contractor shall take all site requirements into consideration and include cost of all miscellaneous items which are essential and required for entire completion of work in their quoted rates which are not specifically mentioned in Schedule 'A' and in Particular specifications. All items which are required for completion of works of Central chilled water type AC plant are deemed to be included in the unit rates.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
Contd Srl item No 18...... (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Galvanised iron strip 32 x 6mm buried in ground alongwith saddle complete all as specifed and directed by Engr-in-Charge
Non return Valve of size 100 mm dia PN 1.6, Body Seat Ring Gun Metal & Seat Ring Rubber,Flanged Ends, body test 2.4 MPa Hyd (348 Psig Hyd) complete all as specified and directed by Engr-in-Charge.
Description all as per above item but 150 mm dia
S & F Butterfly Valve of size 100 mm dia PN 1.6, Body Seat Ring Gun Metal & Seat Ring Rubber,Flanged Ends, body test 2.4 MPa Hyd (348 Psig Hyd) complete all as specified and directed by Engr-in-Charge .
Description all as per above item but 150 mm dia
S & F Y strainer 100 mm dia PN 1.6, Body Seat Ring Gun Metal & Seat Ring Rubber,Flanged Ends, body test 2.4 MPa Hyd (348 Psig Hyd) complete all as specified and directed by Engr-in-Charge.
S & F Y strainer 150 mm dia PN 1.6, Body Seat Ring Gun Metal & Seat Ring Rubber,Flanged Ends, body test 2.4 MPa Hyd (348 Psig Hyd) complete all as specified and directed by Engr-in-Charge.
Supply and fixing of perforated Hot Dipped Galvanized Iron cable tray made out of 2.0 mm thick galvanized iron sheet of following size cable tray with perforation not more than 17.5% including all accessories i.e bends, coupler, cable tie, joined with connectors, suspended from the ceiling with G.I. suspenders, G.I. bolts & nuts, etc as required, complete all as specified and directed .
Size: 450 mm Wide x 100mm Ht
Size: 150 mm Wide x 100mm Ht
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed by Engr-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground floors), complete all as specified and as directed by Engr-in-Charge.
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Providing, Plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges, including mixing Liquid water proofing compund in the proprotion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:4) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm and applying two coats of aluminium paint on roof complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 450mm x 300mm x 7 to 8mm on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
100 mm thick, Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in flooring finishing the surfaces even and smooth without using extra cement with Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green , complete all as specified and as directed by Engr-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-2 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Plain cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and as directed by Engr-in-harge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed by Engr-in-Charge.
75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in sub base to floors complete, all as specified.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:3, complete all as specified.
Machine cut kota stone slab flooring 12 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
M&L Coloured Chequered cement concrete tiles, machine pressed, factory made of size 250mm X 250mm X 20-22mm) thick, set, jointed and pointed in neat cement slurry and pointed with grey cement mixed with pigment, laid including and over 20mm thick screed bed in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over and including a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Taking up or down 15/ 20mm bore steel tubing and connections including all fittings and removing to store.
15 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
20 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, , complete all as specified and as directed by Engr-in-Charge.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 20mm fixing in repair , all as specified.
PVC connections 15 mm size with PTMT nuts of length 450 mm and washers, complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose of dia 125mm with swivel joint fixed to pipe or union of 15 mm, with shower arm casted 195mm long heavy casted body with wall flanges of PTMT any colour, ISI marked, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete alll as specified and as directed,
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
S&F Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Drapery rod (MS conduit) of dia not less than 25 mm having a corrugated virgin PVC extrusion on it & finials of approved shade with standard MS powder coated/ brackets including end caps, fixed to walls with rawl plugs and steel screws, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site complete all as specified.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified.
Dismantling of Steel rolling shutters of any description not otherwise provided for complete all as specified and as directed.
Steel rolling shutters, having thickness of laths 1.25mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type and one shop coat of red oxide primer complete all specified.
Ball bearing for rolling shutters complete all specified.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item above No 80 but without glazing bar complete all as specified and as directed.
Factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for, filling as in the pressed steel door frame/hold fast complete all as specified.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-O or Gde-E-165, complete all as specified and as directed.
Rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe 290 (E-165) complete all as specified.
18/19mm thick Prelaminated particle board, termit proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, shelves etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified.
2nd class soft wood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc. complete all as specified and as directed by Engr-in-charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with first class wooden beading or tinned tacks or galvanised wire staple fixed in repair complete all as specified .
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Vitreous China urinals, half stall (back or corner wall type) white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed casing and caping medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 97 above but one 3/5 pin 15 Amp socket outlet on the same board with other switch with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 97 above but one 3/5 pin 5 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 1.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Lamp holder pendent/batten/angular type/polycarbonate insulated metal cased body with brass adeptor suitable for batten fitting complete dully fixed on suitable size of PVC block, complete all as specified and as directed.
Switch piano flush button single pole one way 5 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 15 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket outlet, 2 in 1, 3 pin, 15 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. (Note: MCBs will be measurd separately).
MCB SP, 6 to 32 Amps,240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 6 sqmm 2 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Supply & Fixing in replacement of LED street Light fitting 90 Watt, New Generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 with acrylic, Powder coated, pressure die cast aluminium compact High Power LED street light with Heat resistant toughened Glass, Corrosion resistant, isolated driver CRI ≥ 70, PF ≥ 0.90, surge protection upto 5.0, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 5700K-6500K, Low heat generating LED complete making all connection with MCB SPN along with MCB Box enclosure, complete all as per the directions of Engr-in-Charge. NOTE: (i) Make of light fittings shall be as specified in particular specifications (ii) The contractor shall obtain LM 80 & LM 79 (From third party NABL lab only & inhouse NABL lab test will not be considered) reports for the light fittings from the manufacturer before supply of material and submit to the department. (iii) A certificate from the manufacturer for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE
Slim linear LED lighting fixture 20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. NOTE: A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.
Street light bracket for fixing of LED light on wall with 40/50 mm dia GI pipe 1.5mtr long bent to shape with suitable type and size of MS clamp of size 40mmx5mm thick MS clamp of size 40mmx5mm thick MS flat nuts, bots and washer duty painted, completed all as specified and as directed by the Engr - in - Charge
LUXMI ELECTRONIC WORKS
Electromech Engineers
Comfort Systems
KEWAL SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .