Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-Finance | L1 | Accepted-Finance AS PER BOQ | |
| 2 | L2₹20.3 L+₹84,090 (4.33%)Accepted-Finance AMBEDKAR GRAM JIGINI SE AMBEDKAR GRAM BHELKHA MARG | JAMUI | BIHAR | 811308 | L2 | Accepted-Finance AS PER BOQ | |
| 3 | L3₹24.5 L+₹5.0 L (25.9%)Accepted-Finance GRAM POST MAWANA KHURD MAWANA MEERUT | MEERUT | UTTAR PRADESH | 245206 | L3 | Accepted-Finance AS PER BOQ | |
| 4 | L4₹41.2 L+₹21.7 L (112.0%)Accepted-Finance | L4 | Accepted-Finance AS PER BOQ | |
| 5 | L5₹43.6 L+₹24.2 L (124.6%)Accepted-Finance | L5 | Accepted-Finance AS PER BOQ |
| Sl No | Description | Qty | Unit | M/s Abinav Enterprises L1 | M/s Raj Kishor Contractor L4 | A K CONTRACTOR L2 | SHIV CONTRACTOR L3 | GYAS PAL CONTRACTOR L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Detail of Work | ||||||||
| 1.01 | Safely carriage of PCC poles up to 11 Mtr. Long from ESC, SRE to site of work including loading & unloading at both ends.. | 24 | No | 2,000 ₹48,000 Lowest | 3,200 ₹76,800 | 2,000 ₹48,000 Lowest | 2,510 ₹60,240 | 3,000 ₹72,000 |
| 1.02 | Safely carriage of other complete line material LT PVC cable/ACSR DOG Conductor (Except PCC Poles) from ESC, SRE to site of work including loading, unloading at both ends. | 3 | Ton | 2,000 ₹6,000 Lowest | 3,200 ₹9,600 | 2,000 ₹6,000 Lowest | 2,510 ₹7,530 | 3,000 ₹9,000 |
| 1.03 | Safely carriage of 100 KVA T/F from ESC, SRE to site of work including loading & unloading at both ends.. | 2 | No. | 7,000 ₹14,000 | 6,000 ₹12,000 | 8,000 ₹16,000 | 9,100 ₹18,200 | 5,500 ₹11,000 Lowest |
| 1.04 | Safely carriage of 250 KVA T/F from ESC, SRE to site of work including loading & unloading at both ends.. | 2 | No. | 12,000 ₹24,000 Lowest | 15,000 ₹30,000 | 12,000 ₹24,000 Lowest | 15,000 ₹30,000 | 14,000 ₹28,000 |
| 1.05 | Safely carriage of 11 KV Fuse set from ESC, SRE to site of work including loading & unloading at both ends.. | 4 | No. | 2,500 ₹10,000 Lowest | 3,500 ₹14,000 | 2,500 ₹10,000 Lowest | 3,000 ₹12,000 | 3,000 ₹12,000 |
| 1.06 | Safely carriage of 11 KV TPMO from ESC, SRE to site of work including loading & unloading at both ends.. | 4 | No. | 2,500 ₹10,000 Lowest | 3,500 ₹14,000 | 2,500 ₹10,000 Lowest | 3,000 ₹12,000 | 3,000 ₹12,000 |
| 1.07 | Safely carriage of LT XLPE Cable size 1X240 sq mm from ESC, SRE to site of work including loading & unloading at both ends.. | 180 | Mtr. | 20 ₹3,600 Lowest | 150 ₹27,000 | 20 ₹3,600 Lowest | 21 ₹3,780 | 160 ₹28,800 |
| 1.08 | Safely carriage of Earthing rod from ESC, SRE to site of work including loading & unloading at both ends.. | 90 | No. | 50 ₹4,500 Lowest | 50 ₹4,500 Lowest | 51 ₹4,590 | 51 ₹4,590 | 60 ₹5,400 |
| 1.09 | Erection of single support on PCC poles up to 11 Mtr. Long with complete fitting of all accessories of 33KV/11 KV /LT line. complete. | 16 | No | 1,800 ₹28,800 Lowest | 3,200 ₹51,200 | 2,000 ₹32,000 | 2,000 ₹32,000 | 3,000 ₹48,000 |
Tender Value
₹20.7 L
EMD Value
₹20,670
Closing Date
16 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle II Saharanpur
Various work of business Plan 2025-26 in area EDD Rampur Maniharan sre
2025_PVVNL_1072810_1
50/W/EDC II/SRE/2025-26
Open Tender
Electrical Works
Lump-sum
60 days
SAHARANPUR
Please refer tender document
2 documents required · 2 mandatory
₹3,540
Yes
SE EDC II SRE
₹20,670
Yes
8 Oct 2025
10 Sept 2025
16 Sept 2025
10 Sept 2025
16 Sept 2025
10 Sept 2025
Amount
Detail of Work
Safely carriage of PCC poles up to 11 Mtr. Long from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of other complete line material LT PVC cable/ACSR DOG Conductor (Except PCC Poles) from ESC, SRE to site of work including loading, unloading at both ends.
Safely carriage of 100 KVA T/F from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 250 KVA T/F from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 11 KV Fuse set from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 11 KV TPMO from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of LT XLPE Cable size 1X240 sq mm from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of Earthing rod from ESC, SRE to site of work including loading & unloading at both ends..
Erection of single support on PCC poles up to 11 Mtr. Long with complete fitting of all accessories of 33KV/11 KV /LT line. complete.
Erection of D/P with PCC poles up to 11 Mtr. Long with complete fitting of all accessories.
Safely Installation of 11 KV Fuse set and connection Properly
Safely Installation of 11 TPMO and connection Properly
Fixing of earthing rod
Providing and Fixing of Double Circuit Tail less unit 300 amp. incoming Circuit connected with copper Bus Bar of proper Rating for 250/400/630 KVA T/F. in the Frame made of MS Angle 45x45x5 mm Fitted with G.I Nut Bolt & Fixing the same Top of Plinth/Near Ground level as per Site Requirement
Providing and fixing 11 KV Danger board barbed wire including jumper
Providing and fixing Stone pad 300x300x75 mm
Earthing of poles by earthing rod 2540x20 mm
Providing and fixing LT Incoming panel with metering eq & fix arra.
Providing and fixing Copper L-Picec 50x225x10 mm
Providing and fixing Al Lug with nut & bolts
Providing and fixing Al crimping Lug size 185 mm
Providing and fixing Dead and clamp
Providing and fixing J-HOOK Clamp
Providing and fixing Clamp
Providing and fixing LT fuse set
Providing and fixing Holding clamp for top channel TPMO & fuse set etc with nut& bolts made of new MS flat flat iron 50x6 mm
Providing and fixing Clamp for LT T-off bolts & Nuts
Grouting of Stay set complete 16x1800 mm
Fabrication Charges of Angel & Channal.
Providing and Fixing Earthing Strip 25x3 mm (02 No) (Length 14 FEET) Nut Washer and welding charge each.
Providing and Fixing Bakelite Strip with connector with fuse wire of size 40/38/37 SWG ON 11 KV Busing of 25/63/100 KVA DT (03 No) each.
Providing LT fuse set installed in SMC Box for 25/63 KVA T/F
Concreting of PCC pole up to 11 Mtr. Long with cement concreting in block of 600x600x1500 mm in ratio 1:4:8 with cement, sand and brick ballast size 1x1.5”
Laying, lifting, stringing, sagging jumpering & binding of ACSR DOG Conductor for 33KV/11KV/LT Line as per RESPO specification.
Laying of LT PVC cable size 3.5/70/35 sq mm as per RESPO specification.
Laying, lifting, Stringing, proper sagging of LT XLPE Cable size 1X240 sq mm. including fixing of all type clamp and connector of all accessorie .
Safely carriage of LT ABC cable of size 3x95+1X70+1X16 sq.mm from ESC, SRE to site of work including loading & unloading at both ends..
Laying, lifting, Stringing, proper sagging of LT ABC cable of size 3x95+1X70+1X16 sq.mm. including fixing of all type clamp and connector of all accessorie .
Constriction of plinth for installation of 250 KVA T/F of size 2x2x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC Top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall.
Constriction of plinth of Isolator
Removal of 100 KVA T/F From the D/P & Carriage From Site to ESC, SRE including loading & unloading at both ends.
Safely installation of New 100 KVA T/F on the plinth by private crain with proper alignment and Complete fitting including making connection and commissioning
Safely installation of New 250 KVA T/F on the plinth by private crain with proper alignment and Complete fitting including making connection and commissioning
Water level Earthing with pipe of Isolator
Water level Earthing of 250 KVA T/F (1 No body & 1 No. neutral earthing) by boring & fixing of G.I pipe 1½ Dia (Jindal Class B) and connecting with G.I. Strip of size 40x4 mm and G.I wire at bottom of G.I pipe to the T/F providing of required charcoal & salt in the pipe.
Providing & Making of Wiremesh fencing size 2.5x2.5x2.5 mtr with grouting making frame of MS angle 45x45x6 mm and fixing four no MS strip size 25x6 mm at equal distance in between the frame and fixing square mesh of 50 mm squre in each frame the fencing should cover all side of T/F with providing 1 no door size 6’x3’ with sitakni & dandala with green paints (British/Asian/enamel paints)
Safely carriage of 11 KV I/C New VCB 600/300/5 Amp (05 No) & 11 KV O/G VCB 300/150/5 Amp (04 No) from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 33 KV New VCB (Outdoor) from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 33 KV PT unit from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 33 KV CT unit 200/100/1-1A from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 33 KV Control panel Double T/F from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of 33 KV Lightning Arrester from ESC, SRE to site of work including loading & unloading at both ends..
Safely carriage of Copper Control cable 6x2.5 sq mm from ESC, SRE to site of work including loading & unloading at both ends
Safely Installation of 11 KV I/C New VCB 600/300/5 Amp (05 No) & 11 KV O/G VCB 300/150/5 Amp (04 No) complete with fixing and making cable connection with proper alignment in all respect.
Safely Installation of 33 KV New VCB (Outdoor) complete with fixing and making cable connection with proper alignment in all respect.
Safely Installation of 33 KV PT unit complete with fixing and making cable connection with proper alignment in all respect.
Safely Installation of 33 KV CT unit complete with fixing and making cable connection with proper alignment in all respect
Safely Installation of 33 KV Control panel Double T/F complete with fixing and making cable connection with proper alignment in all respect.
Safely Installation of 33 KV Lightning Arrester complete with fixing and making cable connection with proper alignment in all respect
Removal of old & damaged 11 KV I/C & O/G (09 No.) and 33 KV VCB (08 No.) after opening of all connection and nuts & bolts with carriage from site to ESC SRE including loading & unloading at both ends.
Laying of control cables of size 6x2.5 mm
Water Level Earthing of 11 KV Incoming /Outgoing VCB by boring 60 ft. deep and providing & fixing 60 ft. G.I. pipe 1½ dia (Jindal class B) and connecting with G.I. strip of size 40x5 mm with providing of requireed charcoal and salt in the pipe properly.
Grouting of New Structure
A K CONTRACTOR (BID ID -5536337)
SHIV CONTRACTOR (BID ID -5534048)
M/s Raj Kishor Contractor (BID ID -5537604)
GYAS PAL CONTRACTOR (BID ID -5538098)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .