| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹8.8 L+₹39,261 (4.66%)Rejected-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L2 | Rejected-AOC Being other than lowest bidder | |
| 3 | L3₹9.8 L+₹1.4 L (16.7%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC Being other than lowest bidder |
| Sl No | Description | Qty | Unit | M/s badrinath Traders L3 | Mohinder Pal and Sons L2 | AGGARWAL & CO L1 |
|---|---|---|---|---|---|---|
| 1.00'Notes: (i) Please refer Schedule 'A' Notes of tender documents. | ||||||
| 2.00 | SCHEDULE 'Á' SECTION-I: (REPAIR TO GEYSERS WORKS)
Note:-
Attending of day to day complaints of geysers by draning out the water and taking down carefully from wall after unscrewing nut/bolts geyser 25 to 50 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc including replacement of defective unserviceable parts, reassembling and refixing after repair all as specified and as directed by Engr-in-Charge.
Note: i) Spares shall me measured and paid sepratley under respective items of Sch.
ii) Penal charges of Rs 250 per day per complaint shall be imposed on contractor for not attending the complaint within 24 hrs. | 500 | Each | 100 ₹50,000 | 90 ₹45,000 | 50 ₹25,000 Lowest |
| 3.00 | Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts Circular/triangular shape rating as required at site including rubber washers complete, all as specified and as directed. | 210 | Each | 300 ₹63,000 | 280 ₹58,800 Lowest | 350 ₹73,500 |
| 4.00 | Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts special type suitable for Bajaj / CG Geyser ( as per sample ) shape rating as required at site including rubber washers complete, all as specified and as directed. | 20 | Each | 300 ₹6,000 Lowest | 325 ₹6,500 | 350 ₹7,000 |
| 5.00 | Supply and replace thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius, complete all as specified and directed. | 230 | Each | 150 ₹34,500 | 150 ₹34,500 | 120 ₹27,600 Lowest |
| 6.00 | Supply and replace special type thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius for Bajat/CG Gerysers ( as per sample ) , complete all as specified and directed. | 20 | Each | 300 ₹6,000 | 175 ₹3,500 | 170 ₹3,400 Lowest |
| 7.00 | Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , complete all as specified and directed .
Note: The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor . | 20 | Each | 800 ₹16,000 | 700 ₹14,000 | 600 ₹12,000 Lowest |
| 8.00 | Supply and replacement internal steel tank of geyser 50 ltr capacity complete with syphon –assembly, 2.0 kw element , rubber gasket , thermostat switch , complete all as specified and directed.
Note: The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor . | 2 | Each | 2,000 ₹4,000 | 850 ₹1,700 | 800 ₹1,600 Lowest |
| 9.00 | Supply and replacement of syphon assembly made out of brass suitable for 25 ltr capacity geyser incl necessary studs, screws and rubber gasket/washers complete all as specified and directed. | 20 | Each | 800 ₹16,000 | 500 ₹10,000 | 100 ₹2,000 Lowest |
| 10.00 | Supply and replacement of syphon assembly made out of brass suitable for 50 ltr capacity geyser incl necessary studs, screws and rubber gasket/washers complete all as specified and directed. | 2 | Each | 1,500 ₹3,000 | 525 ₹1,050 | 500 ₹1,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
31 Jul 2025, 6:00 pmClosed
Garrison Engineer (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH SANGRUR ROAD PATIALA CANTT
As per tender documents
2025_MES_718318_1
GE(S)/PAT/T-27/2025-26
Open Tender
Civil Works
Item Rate
240 days
Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹30,000
Yes
20 Sept 2025
3 Jul 2025
2 Aug 2025
3 Jul 2025
31 Jul 2025
17 Jul 2025
3 Jul 2025 - 10 Jul 2025
Amount
'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
SCHEDULE 'Á' SECTION-I: (REPAIR TO GEYSERS WORKS) Note:- Attending of day to day complaints of geysers by draning out the water and taking down carefully from wall after unscrewing nut/bolts geyser 25 to 50 Ltr capacity and opening the same for taking out internal tank, syphon assembley etc including replacement of defective unserviceable parts, reassembling and refixing after repair all as specified and as directed by Engr-in-Charge. Note: i) Spares shall me measured and paid sepratley under respective items of Sch. ii) Penal charges of Rs 250 per day per complaint shall be imposed on contractor for not attending the complaint within 24 hrs.
Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts Circular/triangular shape rating as required at site including rubber washers complete, all as specified and as directed.
Supply only heating unit (element) 240 volt AC ISI marked of 1500 watts special type suitable for Bajaj / CG Geyser ( as per sample ) shape rating as required at site including rubber washers complete, all as specified and as directed.
Supply and replace thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius, complete all as specified and directed.
Supply and replace special type thermostat switch suitable for 25/35/50 ltr geyser AC 230 volt adjustable range from 0-90 degree Celsius for Bajat/CG Gerysers ( as per sample ) , complete all as specified and directed.
Supply and replacement internal steel tank of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , complete all as specified and directed . Note: The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor .
Supply and replacement internal steel tank of geyser 50 ltr capacity complete with syphon –assembly, 2.0 kw element , rubber gasket , thermostat switch , complete all as specified and directed. Note: The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor .
Supply and replacement of syphon assembly made out of brass suitable for 25 ltr capacity geyser incl necessary studs, screws and rubber gasket/washers complete all as specified and directed.
Supply and replacement of syphon assembly made out of brass suitable for 50 ltr capacity geyser incl necessary studs, screws and rubber gasket/washers complete all as specified and directed.
Supply and replacement outer body suitable for 25 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete, all as specified and directed.
Supply and replacement outer body suitable for 50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing, complete all as specified and directed.
Supply and replace glass wool of 25 ltrs capacity geyser, complete all as specified and directed.
Supply and replace glass wool of 50 ltrs capacity geyser, complete all as specified and directed.
Supply and replace indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt, complete all as specified and directed.
Supply and replace PVC connection 15mm dia 60 cm long complete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed.
Supply and replace PVC connection 15mm dia 90 cm Longcomplete with brass flair nuts at both ends. ( ISI marked and suitable for hot water supply upto 100 degree celcius), complete all as specified and directed.
Supply and fixing anchor bolt 12mmX100mm long complete all as specified and directed (Note:- Anchor bolt shall be grouted with drill machine only) incl making good the disturrbed surfaces of wall all as directed.
Supply and fixing in replacement of defective mild steel base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed.
Supply and fixing in replacement of 15mm stop valve CP fancy type,cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe unions and suitable, complete all as specified and directed.
Supply and fixing in replacement of 1100 Volt grade cable flexible 3 Core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm, complete all as specified and as directed.
Supply and fixing in replacement of CP connection brass with flair nuts all as per sample, complete all as specified and as directed.
M& L for dismantling of Geyser 25/50 ltr capacity for dscalng/cleaning of blocked steel tank with ceaning agent and refixing the same on its original position all as specified and directed.
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN MCB 16/20 Amps, complete all as specified and as directed.
Supply and fixing in replacement of mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lenghts, with and including all fittings such as sockets, bends, elbow, unions, tees, diminishing pieces etc, fixed to wall or ceiling or in floor complete all as specified and directed.
Supply and fixing plug top 15 Amp three pin for geysers, complete all as specified and directed.
S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm dia, complete all as specified and as directed.
SECTION-II: REPAIR TO SOLAR WATER HEATING SYSTEM Attending of day to day Solar Water Heating System complaints taking down, opening up, reassembling, refixing and testing of Solar Water Heating System including replacement of unserviceable parts wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor for efficient functioning of Solar Water heating System. The cost of material will be measured and paid seperately for replalacement of parts complete all as specified and directed. Note: (i) Schedule of repair to Solar Water heating System is catered for attending day to day complaints of different items within the prescribed time schedule as decided by the EIC on complaint slip, failure to attend the complaint within the prescribed time shall attract a penalty of Rs 250 per day per complaint. Note: All repair to Solar water heating system shall be carried out from an authorized person of the manufacturer of the system and proof there of shall be produced to the GE before undertaking repairs. Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting the rates of this item.
Supply and replacement solar flat plate collector having collection area not less than 3.0 sqm made out of aluminium frame and toughened glass suitable for solar panel system complete all as specified and directed. (Note :- The item will be as per site requirement of existing to suitable to connect the new plte with existing plate and water pipes.
Supply & fix in repairs Heating element, 3 KW, ISI marked, copper sheathed, nickel plated suitable for any type, make, size of solar water geysers, complete all as specified and directed.
M&L for De scaling of solar water heater complete of 100 to 1000 LPD capacity using suitable chemical agent including replacement of Unsv nut bolts washer etc complete all as specified and directed.
M&L for preparing new surface of steel of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L for Anchoring with new fasterns and PCC (1:2:4) work for footing (round/square shape as per site requirement) of legs of roof mounted Solar Water Heater panels including, complete all as specified and directed.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality cable of size 6 sqmm twin core.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality cable of size 4 sqmm twin core.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality cable of size 2.5 sqmm twin core.
S&F in replacement of pressure dia cast aluminium housing LED street light luminaires of 25 watt with IP-66 including connecting to junction box complete all as specified and directed.
S&F in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box complete all as specified and directed.
All as per item No. 38 above but 60 Watt, complete all as specified and directed.
All as per item No. 38 above but 70 Watt, complete all as specified and directed.
All as per item No. 38 above but 90 Watt, complete all as specified and directed.
S&F in replacement LED flood light 30 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP-66 Protection, with impact and corrosion resistant complete with driver and lamp complete with all accessories required for fixing arrangements all as specified and directed by the Engr-in-charge.
All as per item No.42 above but 70 Watt, complete all as specified and directed.
All as per item No.42 above but 100 Watt, complete all as specified and directed.
All as per item No.42 above but 170 Watt, complete all as specified and directed.
S&F in replacement Post Top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative Post Top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete duly connection with control switch icluding mounting on suitable size GI Pipe complete all as specified and directed.
S&F in replacement LED 10 Watt Bolard Light IP-65, height upto 600/700 mm ceramic body in silver/black colour have base E40 type energy saving, environmental friendly with high power LEDs as light source Warm white type including cost of masonary work for fixing/mounting by making sqaure/round PCC platform in the garden duly cement plastering and white wash complete all as specified and directed.
M&L for repair of street light automatic power control panel by replacement of unsv timer switch, RYB indicator, MCB TP 32 Amps, MCB SP/SPN upto 6-32 Amps and unsv wiring etc. including testing for smooth functioning of panel, complete all as specified and directed.
S&F in replacement three Phase Street Light Junction box (IP-55) suitable for mounting on LT RCC pole/stell tubular pole, box having aluminium busbar 20 Amp rating with 6 Amp MCB ('B' series) control, mounted on insulators with 2 clamps of Aluminium strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc front openable hinged cover suitable for mounting on steel clamps nut bolt etc pvc adopters and PVC hose pipe upto cable treench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
S&F in replacement DBs sheet metal enclosure 2 ways for fixing of SP/SPN MCB on pole/wall mounting incl cost of MCB complete all as specified and directed.
S&F in replacement of MCB SPN 6-20 Amps 230 volts 'B' Series, complete all as specified and directed.
S&F in replacement brackets 1.2 m long made to shape fabricated out of GI pipe Light grade ISI marked 40 mm dia incl provn of socket nipple welded at once end to suit the light fitting and fix to pole including clamps with nuts and bolts of suitable size cutting, drilling and welding its fix to pole and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&Fin replacement of PVC Conduit of size 15 mm incl all connected accessories (bends, clamps, PVC union & screws etc) incl disconnecting of existing calbes/wires from LED fitting/junction box and inserting the same in the conduits complete all as specified and directed.
M&L for painting of street light GI pipe 25/40 mm with one coat red oxide and synthetic enamel paint of silver colour including painting of metal clamps complete all as specified and directed.
M&L for painting of street light tubular pole upto 8 mtr high with one coat red oxide and double coat of synthetic enamel paint of silver colour including painting of metal clamps, bend and painting of alternate layers in yellow & black paint complete all as specified and directed.
Supply and fix in replacement electronic driver with power factor correction suitable for 45/50/60 Watt LED street lights, input AC 85-300V, input frequency 50/60 Hz, output voltage DC 22-38V, output current 1500mA (+-) 5%, waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and as directed.
Supply and fix in replacement electronic driver with power factor correction suitable for 70-90 watt LED street lights, input voltage 70V AC to 300 V AC , power factor 0.99 (Unity) , over voltage 300 V cutt off , short and open circuit protection isolated, surge protection up to 10 to 12 Kv, maximum output voltage 55 Kv, maximum current up to 1.5a waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and as directed.
Mohinder Pal and Sons (BID ID -3368078)
M/s badrinath Traders (BID ID -3377125)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .