Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹86.2 L+₹2.0 L (2.38%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹86.5 L+₹2.3 L (2.68%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹93.0 L+₹8.8 L (10.4%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹96.8 L+₹12.6 L (14.9%)Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Mohit Infratech L6 | RAKESH DUTT SHARMA & SONS L3 | ashika enterprises L2 | MODERN CONCEPT CONSTRUCTIONS L5 | M/s S.K.Industries L4 | Sabur Alam L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: | |||||||||
| 2.00 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 10.8 | cum | 10,000 ₹1,08,000 | 6,600 ₹71,280 | 7,500 ₹81,000 | 6,300 ₹68,040 Lowest | 6,500 ₹70,200 | 8,200 ₹88,560 |
| 3.00Centering and shuttering including strutting, propping etc. and removal of form for | |||||||||
| 4.00 | Lintels, beams, plinth beams, girders, bressumers and cantilevers | 216 | sqm | 450 ₹97,200 | 345 ₹74,520 | 400 ₹86,400 | 230 ₹49,680 Lowest | 400 ₹86,400 | 450 ₹97,200 |
| 5.00Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. | |||||||||
| 6.00 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | 479.52 | kg | 100 ₹47,952 | 88.5 ₹42,437.52 | 120 ₹57,542.4 | 90 ₹43,156.8 | 90 ₹43,156.8 | 85 ₹40,759.2 Lowest |
| 7.00Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. | |||||||||
| 8.00 | Hot finished welded type tubes | 8,400 | kg | 150 ₹12,60,000 | 94.8 ₹7,96,320 Lowest | 110 ₹9,24,000 | 99 ₹8,31,600 | 98 ₹8,23,200 | 95 ₹7,98,000 |
| 9.00Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. | |||||||||
| 10.00 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | 530.53 | kg | 150 ₹79,579.5 | 88.5 ₹46,951.91 Lowest | 110 ₹58,358.3 | 100 ₹53,053 | 95 ₹50,400.35 | 95 ₹50,400.35 |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
26 Nov 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Office of the Executive Engineer (Civil Division-III), Room No- MZ-137, Main Building, IIT Delhi, Hauz Khas, New Delhi-110016
Replacing of Damage Polycarbonate sheet for different location of academic area at IIT Delhi
2025_IIT_885867_1
IITD/WORKS (SP-5172)/2025
Open Tender
Civil Works
Works
180 days
IIT Delhi Hauz Khas
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹2.6 L
5 Jan 2026
17 Nov 2025
27 Nov 2025
17 Nov 2025
26 Nov 2025
17 Nov 2025
Amount
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
6 mm cement plaster of mix:
1:3(1 cement :3 fine sand)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Supply & Fixing of 16 mm thick Polycarbonate multiwall sheet (2 cells & 3 Walls) as per drawing and as directed by engineer in charge having weight of 2.7 Kg/sqmt. The sheet Should have linear thermal expansion of 0.000065 /K & thermal conductivity 0.20 w (m-k). Sheet shall be remain stable between - 40C to 120C. Length & width of the sheet should be as per detailed drawings & design. polycarbonate sheet should have 50 microns Co-extruded UV protected on top Layer (exposed to Sun ). Poly carbonate sheet shall not remove any toxic fumes and hence pose no hazard to human life in case of fire. The sheet shall be fixed with 3mm thick and min. 58mm – 60mm wide Aluminum flat/Glazing Bar on the longitudinal joint & applied with a layer of EPDM rubber over the sheet. The joint between sheet & the Aluminum Joint shall be fully filled with RTV silicon sealant of approved make to avoid water leakage from the joint complete as per drawing and as directed by engineer in charge. The sheet shall be fixed to the structure with help of SDST screws.(Structural steel should be paid in relevant item). (Make: COXWELL, NOVALITE, GE lexan or polygal brand )
Dismantling of Polycarbonate roofing Sheet including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead.
Extra for Bending of circular / square / rectangular or any other MS-Section in desired shape as per drawings and direction of Engineer in Charge.
Electrical Work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ subnnain wiring/ cable as required.
LED Light Fixtures
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of 18-22 watts following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter of 12-15 watts (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 35 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%),, Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, with Lithium-Iron Phosphate Battery LiFePO4), charging time 8-10 hours, Battery backup time 12 hours (minimum), LED fixture watt 35 watt, Input voltage: 12V DC , Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15 , lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)), life time (LED, Driver & electrical circuitry) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 35 Watt (System lumen efficacy >120 lm/Watt)
Supplying, installation DLP mini- trunking 32mm x 20mm with independent cover etc. complete as reqd.[Make Legrand]
PVC mini trunking with independent cover of size 32mm x 20mm size.
PVC mini trunking End cap left or right.
Dismantling/ Disconnecting old damages services.
Dismantling, disconnecting old damaged unserviceable fl fitting/ exhaust fan/ ceiling fan/ bulkhead fitting with bracket etc. as reqd.
Dismantling of switch / socket /regulator etc. with wooden board as reqd.
Dismantling damaged DB/TPN Switches/ loose wire boxes along with all accessories as required.
[--] Less Credit for Dismantled Materials.(These are tentative, may vary as per actual.)
Less buyback of old light fixture etc. on as is where is basis.
Less buyback of 5/15 Amp Switch/ socket etc. on as is where is basis.
Less buyback of old aluminium wiring on as is where is basis.
Less buyback of Old DB box/ Steel enclosure etc. on as is where is basis.
Less buyback of Old and unserviceable MCB/ MCCB etc. on as is where is basis.
Credit of Polycarbonate sheet .
ashika enterprises (BID ID -3323052)
RAKESH DUTT SHARMA & SONS (BID ID -3322496)
M/s S.K.Industries (BID ID -3323616)
MODERN CONCEPT CONSTRUCTIONS (BID ID -3323185)
Mohit Infratech (BID ID -3322019)
stage.html
html • 0.04 MB
techsummary_931140.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.23 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_931140.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .