Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 94 BAPUJI NAGAR BHUBANESWAR | KHORDHA | ODISHA | 751001 | Admitted-Finance |
| 2 | Admitted-Finance 57 081 GANGOTRI NAGAR SISUPAL GARH OLD TOWN KHURDA KHORDHA ODISHA 751002 | KHORDHA | ODISHA | 751002 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically not qualified as per the NIT |
Tender Value
₹20.0 L
EMD Value
₹39,944
Closing Date
15 May 2025, 4:00 pmClosed
DIRECTOR, CSIR-IMMT, BHUBANESWAR
CSIR-IMMT, BHUBANESWAR
Electrical renovation of different laboratories, office rooms, power supply arrangement to new equipments and other allied works at CSIR-IMMT, Bhubaneswar 751013
2025_CSIR_234648_1
01/IMMT/ESD(E)/2025-26/425
Open Tender
Electrical Works
Item Rate
330 days
CSIR-IMMT, BHUBANESWAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DIRECTOR, CSIR-IMMT, BHUBANESWAR
₹39,944
27 May 2025
8 May 2025
16 May 2025
8 May 2025
15 May 2025
8 May 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm ISI marked FRLS PVC insulated single core copper conductor (Finolex/Poly-Cab/RR/KEI make) cable in surface/ recessed PVC conduit medium ( AKG/Kinjal/Polycab/Precision make) with piano type switch, phenolic laminated sheet, suitable size M.S. box incorporated with Neutral & Earth link & earthing the point with 1.5 sq mm green colour FRLS PVC insulated single core copper conductor cable etc as required. Neutral & Earth wire to come to Switch Box along with phase as per wiring system etc. Group – C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm (Finolex/ Poly-Cab/RR / KEI make) ISI marked FRLS PVC insulated single core copper conductor cable in surface/ recessed PVC conduit medium class (AKG/Kinjal/Polycab/Precision make) with modular type 5A switch, modular base & cover plate on suitable size modular type metal box (Legrand myrius /schneider clipsal/anchor woods make) make incorporated with Neutral & Earth link & earthing the point with 1.5 sq mm FRLS PVC insulated single core copper conductor cable etc as required. Group – C
Supply and fixing 5/6 amps. piano type switch ( Anchor/Great white/Havells) on the existing switch box/cover including connections etc. as required.
Supply and fixing 15/16 amps. piano type switch ( Anchor/Great white/Havells) on the existing switch box/cover including connections etc. as required.
Supply and fixing 5/6 amps. Socket ( Anchor/Great white/Havells) outlet on the existing switch box/cover including connections etc. as required.
Supply and fixing 15/16 amps. Socket outlet ( Anchor/Great white/Havells) on the existing switch box/cover including connections etc. as required.
Supply and fixing 5/6 amps.modular type (1 module)switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing15/16 amps.modular type (1 module) switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing 5/6 amps.modular type socket (2 module) on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing 5 pin, 15/16 amps.modular (2 module) type socket on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply & fixing of modular type RJ-11 telephone socket in the existing modular box for telephone connection including connection etc as required. Legrand myrius /schneider clipsal/anchor woods make.
Supply & fixing of modular type RJ-45 internet socket in the existing modular box for telephone connection including connection etc as required. Legrand myrius /schneider clipsal/anchor woods make.
Supplying and fixing Modular stepped type electronic fan regulator, 2 module, 120W in the existing modular switch box including connection etc as required. Legrand myrius /schneider clipsal/anchor woods make
Supplying and fixing Flush type Rotary Step 120/280 volt Fan regulator on the existing switch box/cover including connection etc as required. Anchor/Great white/Havells make.
Supply and fixing of 1 or 2 module, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing of 6 module, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing of 16 module, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supplying and fixing modular blanking plate(1 mod) on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of 5amp ceiling rose on the existing junction box/wooden block including connections etc. as required.
Supply and fixing extra down rod of 20cm length GI pipe, 15mm dia (heavy gauge) including painting etc as required.
Supplying & fixing the louvers/shutters and bird protection net complete with frame, up to size of 380 mm sweep exhaust fans etc as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing metal box of 180 mm x 100 mm x 60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required.
Supply and fixing metal box of 200 mm x 300 mm x60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required.
Supply and fixing metal box of 200 mm x 300 mm x100 mm deep (For AC starter enclosure) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable Finolex/ Poly-Cab/RR / KEI make) in surface/ recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable Finolex/ Poly-Cab/RR / KEI make) in surface / recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X10 sq. mm FRLS PVC insulated copper conductor single core cable Finolex/ Poly-Cab/RR / KEI make) in surface / recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 2 Nos. 6 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X16 sq. mm FRLS PVC insulated copper conductor single core cable(Finolex/ Poly-Cab/RR / KEI make) in surface / recessed medium class PVC conduit (AKG/Kinjal/Polycab/Precision) alongwith 2 Nos. 6 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and drawing 3 x 1.5 sq mm of FRLS PVC (Finolex/ Poly-Cab/ RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required.
Supplying and drawing 3 x 4 sq mm of FRLS PVC (Finolex/ Poly-Cab/ RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required.
Supplying and drawing 3 x 6 sq mm of FRLS PVC (Finolex/ Poly-Cab/ RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required.
Supplying and drawing of 2pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required
Supplying and fixing of 20 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab/Precision) including cutting the wall & making good the same in case of recessed conduit etc. as required.
Supplying and fixing of 25 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab/Precision) including cutting the wall & making good the same in case of recessed conduit etc. as required.
Supplying and drawing of UTP 4pair CAT-6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required
Supplying and fixing of 8 way, single pole and neutral, sheet steel,double door MCB distribution board, 240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, hinged gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make
Supplying and fixing of 12 way, single pole and neutral, sheet steel,double door MCB distribution board, 240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, hinged gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make
Supplying and fixing of 4 (4+12) way, Double Door, three pole and neutral, sheet steel, MCB distribution board , 415 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make.
Supplying and fixing of single pole 6 to 32 amps rating, 240 volts MCB (C series) of Legrand/Hager/Siemens/ C &S make in the existing MCB DB complete with connections, testing and commsissioning etc. as requried.
Supplying and fixing 63amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Supplying and fixing 63amp, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 32 A, 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 32 A, 415 V "C" curve FP MCB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top alongwith 20 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25mm x 5mm GI strip in 40 mm dia GI pipe from earth electrode including connection with G.I. nut, bolt, spring, washer exacavation and re-filling etc. as required
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required.
Providing and fixing 4 mm dia copper wire on surface or in recess or in existing pipe along with existing cable for loop earthing etc as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 70 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 4 core x 10 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 core x 25 sq mm or 3.5 core x 35 sq mm or 3.5 core x 50 sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 core x 70 sq mm sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 core x 120 sq mm or 3.5 core x 150 sq mm or 3.5 core x 185 sq mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of street light fitting including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II / IS16205 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 KV grade of 3 core x 6 sq mm size in the existing masonry open duct/ DWC pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 KV grade of 4 core x 10 sq mm size in the existing masonry open duct/ DWC pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 KV grade of 3.5 core x 70 sq mm size in the existing masonry open duct/ DWC pipe as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 core x 10 sq mm size (clamped with 1mm thick saddle) on wall surface as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Suitable for operation on Electronic regulator unit for speed control. (Havells / Crompton / Atomberg or similar model as approved by dept)
Painting of tubular street light pole of height 6.0 mtr to 8.0 mtr height (from ground level / above pole collar level) with one coat of black anticorrosive bitumastic paint upto 1.0 mete r(approx) , priming with one coat of ready mixed red oxide zinc chromite primer & two coats of Aluminium paint at balance area of the pole including street light bracket etc as required. The pole shall be derusted with the help of sand paper before painting.
Cutting holes of required size in brick masonry wall for fixing of ehaust fan including providing and fixing upto 380 mm dia PVC / RCC pipe conforming BIS-12818 and making good the same etc.complete as per direction of engineer-in-charge.
Supplying, installation, testing and commissioning of indoor type wall surface electrical panel made out of 2 mm thickness of metallic sheet steel of tentative panel size 0.6mtr height & 0.3 mtr width (or as approved), including supplying, installation & internal wiring of following mountings complete as required, duly acid treated for derusting, primered and painted with powder coating of approved shade as per engineer in charge. (Manufacturing will be done only in CPRI approved factories) a) Incommer:- One number 125 A, 36KA, FPMCCB with rotary handle SIEMENS / L & T / C & S/ Legrand make b) One number bus-bar chamber comprising four strips (20 mm x 5 mm or equivalent, 100% neutral ) copper bus-bar of suitable length mounted on insulator etc as required
Supplying, installation, testing and commssioning of 400 mm sweep pedastal fan (metal body) with inbuilt regulator of Havells /Crompton / Almonard make
Supplying, installation, testing and commssioning of 400 mm sweep wall fan with inbuilt regulator of Havells /Crompton / Almonard make
Supplying, installation, of Heavy Duty exhaust fan of 380 mm sweep of ( Almonard / Havells/ Crompton make) in the existinge wall, including making the damage good, connection, testing, commissioning etc as required.
Supplying, installation, of light duty fan of 250 mm sweep, PVC body , (Almonard / Havells /Crompton make ) in the existinge wall, including making the damage good, connection, testing, commissioning etc as required.
Supplying, installation, of Heavy duty fan of 300 mm sweep , (Almonard / Havells /Crompton make ) in the existinge wall, including making the damage good, connection, testing, commissioning etc as required.
Supplying & installation, testing and commissioning of prewired round LED fitting of 2000 lumen output not more than 20watt, (Philips / Klite as approved) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
Supplying & installation, testing and commissioning of prewired recessed mounting downlighter square fitting, 2ft x 2 ft of 3000 lumen output, not more than 30watt , (Philips / Klite as approved) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
Supply, installation, testing and commissioning of prewired street light LED fitting of 7500 lumen, not more than 75watt (Philips / Klite as approved ) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc. as required.
Supplying & installation, testing and commissioning of prewired baten fitting/LED channel (box type) suitable for one number LED tube light of (Philips / Klite as approved) with all accessories and 1 no 2000 lumen led tube etc. directly on wall including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required.
Supplying & installation, testing and commissioning of prewired baten fitting/LED channel (box type) suitable for two numbers LED tube light of (Philips / Klite as approved) with all accessories and 2 nos 2000 lumen led tube etc. directly on wall including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required.
Supplying & installation, testing and commissioning of prewired recessed mounting downlighter square fitting, (suitable for 280mm x 280mm or similar size cutout) of 2400 lumen output, not more than 24watt , with all accessories etc in existing false ceiling, including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
Supply, installation, testing and commissioning of 12000 lumen not more than 100 watt LED flood light, (Philips / KLite make) with all accessories etc. as required.
Supplying and fixing of 3 mm thick phenolic laminated sheet including cutting for switch, socket etc. on the existing metal switch board etc as required.
Supplying and fixing FP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Supplying and installation of starter for Air-conditioner, 3-phase DOL starter L&T /Siemens/ C &S make, coil voltage-230 ,Volt 50HZ. & O/L range 9-14 Amps on existing M.S. Box, etc as required .
Supplying & laying of DLP Trunking System (100mm*50mm) Polyvinyl Chloride (PVC),white colour. (Make- Legrand/ AKG / Maruti) with following accessories: 100 mm X 50 mm Body & Cover etc as required as per site requirement
Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex / KEI / RR make) armoured cable as approved by dept. Engg. of 4 core x 10 sq mm size in the open duct / existing trench /pipe etc. as required.
Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex / KEI / RR make) armoured cable as approved by dept. Engg. of 3 core x 6 sq mm size in the open duct / existing trench /pipe etc. as required.
Supplying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade (POLYCAB / Finolex / KEI / RR make) armoured cable as approved by dept. Engg. of 3.5 core x 70 sq mm size in the open duct / existing trench /pipe etc. as required.
M/S MODERN WINDING AND ELECTRICALS (BID ID -850606)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .