Loading…
Loading…
Tender Value
₹4.6 Cr
EMD Value
₹3.8 L
Closing Date
16 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
For Standard Financial Criteria, please refer Para No.1.1.2 of Chapter-I of Tender Document [Also refer to the Para 10.2 of the Tender Form (Second Sheet) of GCC April-2022] and Advance Correction Slip no.1 issued by Railway Board vide letter no.2022/CE-I/CT/GCC-2022/Policy dated 14.07.2022, same is re-iterated below: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of GCC April-2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
For Standard Technical Criteria, please refer Para No.1.1.1 of Chapter-I of Tender Document [Also refer to the Para 10.1 of the Tender Form (Second Sheet) of GCC April-2022].
Defination of Similar Work :- Work of supply &/ or installation, testing and commissioning of earthing/lightening and/ or surge protection. O R Any signalling/ telecom work including supply, installation, testing and commissioning of earthing/lightening and/ or surge protection.
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please refer to the attached documents - "Tender Document" and "GCC April 2022 with all ACS".
Improvement in earthing & surge protection arrangements for S&T equipment's in DD-MMR section's and leftover section's of Pune division for improving reliability of the S&T gears.
CR-PA-SNT-WKS-S-2026-02
CR-PA-SNT-WKS-S-2026-02
Open
Works - General
6 Months
Pune, Maharashtra
₹0
₹3.8 L
16 Mar 2026
20 Feb 2026
2 Mar 2026
91 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,67,00,999.28 | ||
| — | 5.00 | — | — | ||
| Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RDSO) | — | — | — | 7,81,482.6 | |
| — | 5.00 | — | — | ||
| Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RDSO) | — | — | — | 11,63,023.75 | |
| — | 5.00 | — | — | ||
| Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection by RDSO) | — | — | — | 18,41,671 | |
| — | 500.00 | — | — | ||
| Supply of Rubber Mat 5mm thick for use in signalling installation. (Inspection by Consignee) | — | — | — | 71,765 | |
| — | 216.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815. (Inspection by Consignee) | — | — | — | 2,51,182.08 | |
| — | 50.00 | — | — | ||
| A CLASS EARTHING- Supply of ESR ALTEC TERRA STREAMER Lightnig Arrester with SS adaptor (TSP30, 50 Mtr. Radius) SPN: NFC-17-102-2011. (Inspection by RDSO) | — | — | — | 37,09,745.5 | |
| — | 50.00 | — | — | ||
| Supply of FRP Mast with GI Mast (FRP mast at top minimum 1.5 Mtr. along with GI mast 3 Mtr.) Total 4-5 Mtr. Std mast required for mounting the terminal & adaptor to mount the Air terminal with coupler/ reducer. Multi strand stray wires, joints, clamps & accessories as per IS 2309:1989. (Inspection by RITES) | — | — | — | 5,52,571 | |
| — | 50.00 | — | — | ||
| Supply of Test Link Joint Kit in a IP65 weather proof enclosure of suitable dimension and approved make & desig. (Inspection by Consignee) | — | — | — | 1,42,153.5 | |
| — | 75.00 | — | — | ||
| Supply of Lightning Strike Recorder LSC 6 digit shall be weather proof type. It should have 6 digit event count & the capacity to count smallest strike (3KA). It should be voltage sensing type counter. So that it will register nearby strikes & static discharge due to induction effect as per IS 2309:1989. (Inspection by RITES) | — | — | — | 13,05,185.25 | |
| — | 50.00 | — | — | ||
| Supply of UL listed long life Maintenance Free Earthing with constant performance service warranty. UL listed. 250 Micron with ALLTEC-Tera Fill TF 50 & TF-50 XT Back Fill should RoHS & Low resistivity certified. The Back Fill having not more than 0.20 Ohm/cm resisance, eco friendly, non-degradable and non-soluble. The earthing pit shall be designed & supplied with Poly-plastic Pit cover non-conductive, environment friendly. (Inspection by RDSO) | — | — | — | 7,61,535 | |
| — | 50.00 | — | — | ||
| Supply of Down Conductor (recommended:70 Sqmm 19 strand copper insulated cable for lightning current dissipation to earth with necessary fixing clamp, connector accessories etc.) (Inspection by Consignee) | — | — | — | 25,385 | |
| — | 300.00 | — | — | ||
| Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection by RDSO) | — | — | — | 58,76,205 | |
| — | 3000.00 | — | — | ||
| Supply of 35 Sq.mm Multistrand Single Core PVC Insulated Copper for connecting earth bus bar to earth electrode. (Inspection by RITES) | — | — | — | 13,42,410 | |
| — | 3000.00 | — | — | ||
| Supply of Copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round). (Inspection by RITES) | — | — | — | 26,43,960 | |
| — | 50.00 | — | — | ||
| Supply of 300x25x6 mm Cu Equipotential Bus Bar. (Inspection by Consignee) | — | — | — | 73,952 | |
| — | 20.00 | — | — | ||
| Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC as per RDSO/SPN/256/2002 with latest amendments. (Inspection by RDSO) | — | — | — | 32,27,142.6 | |
| — | 8000.00 | — | — | ||
| Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used. (Inspection by Consignee) | — | — | — | 4,63,520 | |
| — | 5000.00 | — | — | ||
| Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@ (Inspection by Consignee) | — | — | — | 4,81,000 | |
| — | 3000.00 | — | — | ||
| Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by RITES) | — | — | — | 9,27,900 | |
| — | 3000.00 | — | — | ||
| Supply of Paints as per relevant IS specification preferably Asian/ Apcolite/Dulux make in different colours in 1 Kg/2 Kg pack (Inspection by Consignee) | — | — | — | 10,59,210 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC April 2022 with all ACS
ATTACHMENT
GCC_April-2022_With_All_Correction_SlipsACS10.pdf
ATTACHMENT
TenderDocument_Earthing.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .