Lt Col Aditya Vanka
GE Navy Lakshadweep Coast Guard Road Kavaratti Islands UT of Lakshadweep 682 555
REPAIRS AND MAINTENANCE OF LIGHTNING ARRESTORS AND RENEWAL OF EARTHING WITH ALLIED WORKS AT KAVARATTI ANDROTH AND MINICOY ISLANDS UNDER GE NAVY LAKSHADWEEP
2021_MES_474337_1
8294/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NAVY LAKSHADWEEP
As per Tender documents
8 documents required · 8 mandatory
₹500
GE Navy Lakshadweep
₹43,000
Yes
7 Jun 2022
10 Sept 2021
11 Oct 2021
10 Sept 2021
8 Oct 2021
24 Sept 2021
13 Sept 2021 - 20 Sept 2021
60 days
Amount
Disconnection and removing the old unserviceable GI strip and supply & laying of lightening conductor madeup of Aluminium conductor, size 25 x 3 mm, fixed to wall on batten or recess or chases or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc... as required complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the old unserviceable GI strip and Supply & laying of lightening conductor madeup of Aluminium conductor, size 25 x 3 mm, buried in ground or any other indicated situation for loop earthing etc…. as required, complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the old unserviceable GI strip and supply & laying of lightening conductor madeup of copper conductor, size 20 x 3 mm, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Earthing complete with galvanised steel plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25mtr below ground level with top edge of earth plate at a depth 1.5mtr below ground level connected with galvanised steel strip of size 32 x 6 mm as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia light grade GI tubing, funnel, wire mesh, 20mm bore GI tubing medium grade watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle of suitable size, charcole and slat in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electrical plate No. 3 of SSR part-I connected to earthing test point and testing complete including taking down of unserviceable materials of old earthing complete all as specified and as directed by Engineer in charge. Note:- (i) GI pipe and GI earth strip upto 7.5 mtr is deemed to be included in the unit rate quoted. (ii) After successfull completion ,testing of earthing should be done by the contractor with his own arrangements and payment shall be made only if the earthing value is less than 5 Ohm
Material and labour for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper earth strip 20 x 3 mm as earthing lead connected by means of bolts, nuts, check nuts and washer of copper, provision of 15 mm dia GI pipe, light grade, for protection of copper strip upto 7.5 meter long and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, GI funnel with wire mesh, test box, 50 mm thick RCC (1:2:4), type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 metre, provision of charcoal and salt complete all as shown in Electrical plate No 3 of schedule Part-I (2009) connected to earthing test point, including taking down old unservicable earthing and earthing strips complete all as specified and as directed by Engineer-in-Charge. Note:- (i) GI pipe and copper earth strip upto 7.5 mtr is deemed to be included in the unit rate quoted. (ii) After successfull completion ,testing of earthing should be done by the contractor with his own arrangements and payment shaal be made only if the earthing value is less than 3 Ohm
Disconnection and removing the old unserviceable GI strip and material and labour for providing Earth continuity conductor or main earthing lead, 25x4 mm galvanised iron strip , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc... complete all as specified and directed by Engineer-in-Charge
Supply and fill the BFC chemical compound for high conductive earthing, complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of porcelain insulators of height not less than 50 mm clearance, fixed to floor/wall/celing and provision for fixing lightning conductor including necessary fixing arrangements such as nut, bolts or welding etc.. complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of lightening Arrestor, 12mm dia, made of copper, complete all as specified and directed by Engineer-in-Charge
Supply and fix single core copper conducor multi stranded of size 25 Sqmm, green copper conductor wire including taking down the old unserviceable one, complete all as specified and directed by Engineer-in-Charge
Supply and laid in trenches or fixed on walls / on roof, GI pipe, light grade of 40 mm dia as mechanical protection to Copper strip 32 x 6 mm/ 20x3 mm with all fittings such as bends, sockets, reducers union etc... complete all as specified and directed by Engineer-in-Charge
Cutting the existing PCC road of width 0.25 Mtr x 0.25 Mtr depth x 3.0 Mtr length for laying the GI pipe light grade with all fittings such as bends, sockets, reducers union etc... including excavation in any type of soil, RFR , removal and filling with PCC (1:2:4), Type B-1 upto 15 cm on the top portion matching with the existing PCC road surfaces and remaining depth with the retrived earth for making the the road cut portion good as per existing, complete all as specified and as directed by Engineer in Charge.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth for taking out /for laying under ground cables/pipes etc... and getting out in soft/loose soil, complete all as specified and as directed by Engineer in Charge.
Returning filling in, with excavated soils incl. spreading, levelling, watering and well ramming in layers not exc. 25 Cms, complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material/ surplus soil not exceeding 50 Mtrs and depositing where directed at a level nit exc. 1.50 Mtr above the starting point, complete all as specified and as directed by the Engineer-in-Charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos., 8mm dia, 25mm long hexagonal head screw, including dismatling old unserviceable terminal blocks, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repairs, CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified 25 mm bore, Including dismantling the old pipes and taking into credit, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ball valve CPVC of size 25 mm dia fixed including dismatling the old ball valve and taking into credit, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing PCC (1 : 3 : 6), type C2, using 40mm graded stone aggregate for foundation including use and waste of necessary form work, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix rotational moulded polythene water storage, triple layered (cylindirical vertical with closed top) hoisting, fixed in position and connecting pipes, capacity 500 ltrs, including dismantling of old water tank and taking into credit, complete all as specified and as directed by Engineer in Charge. Note for Sl Item Nos. 1 to 20: (a) Daily Collecting the complaints from the Department/ Engr-in-Charge is the responsiblity of Contractor. After collecting Complaints from Complaint Register/Site order Book or Insturction by JE by Phone/SMS, complaints should be completed within 48 Hours of receiving the complaint. If complaints are not attended in stipulated time period, double the rate of the item will be recovered. (b) Checking of Earthing resistance of each and every earthing inside the Navy and Coast Guard units in Kavaratti, Androth & Minicoy shall be carried out on monthly basis with help of Earth resistance tester and maintaining the Register of Earthing is responsibility of contractor, without any additional cost effect. (c) If contractor fail to attend complaint within hours a recovery of 5,000/- will charged for each unrolved complaint ( since immediate rectification of defects are required for highly sophisticated equipment installed at these islands). (d) These items will be operated only if found necessary at site during the maintenance period. The contractor has no claim over the operation of full amount / spares under the schedule and payment will only be made accordingly.
R.K. Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .