Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹43.4 L+₹3.9 L (9.75%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹48.5 L+₹8.9 L (22.5%)Rejected-AOC C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹49.9 L+₹10.4 L (26.2%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC Other than L1 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
5 Mar 2024, 6:00 pmClosed
Garrison Engineer
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
ADDN/ALTN ALONGHWITH REPAIR OF PERIMETER SECURITY LIGHTS, CABLE AND POLE ALONG NH INCLUDING PROVN OF MCB DISTR BOXES AND BUS BARS AND CONNECTED ITEMS IN MH AT AKHNOOR AND PROVN OF 15 KVA DG SET FOR FSD SUNDERBANI MIL STN UNDER GE (N) AKHNOOR
2024_MES_640862_1
CANO- GE(N)/AKH-62/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Sunderbani
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GE (North) Akhnoor
₹91,000
Yes
25 Jul 2024
6 Feb 2024
12 Mar 2024
6 Feb 2024
5 Mar 2024
20 Feb 2024
Amount
Supply, installation, testing and commissioning of silent diesel engine driven generating set developing suitable BHP water cooled of capacity 15KVA (12 KW), 415 Volts, 0.8 power factor , mounted on common base frame coupled, 1500 RPM, with silencer pipe protected with asbestos rope independently supported from engine to outside of power house up to 1.00 meter, AVM pads, foundation as per manifacture's design, battery start with suitable cable for connection from DG Set to panel board complete with acoustic enclosure as per specification of pollution control board and including the following:- PRIME MOVER. Vertical diesel engine of suitable capacity having BHP water cooled, closed circuit as per BS-649 or IS-10002 The DG set shall be capable of running 24 hrs continously with 10% overloading for one hour in every 12 hours as per BS-5514/BS-649. Engine shall be equipped with all standard fitting as per manufacture's recomendations and mounted on common base frame with following fittings. RPM cum hour meter Battery charging ammeter V, I, Hz, Pf all as specified and directed. Ignition key and starting with push button switch. Lubrication oil pressure gauge. Mechanical Governor controlling.
Supply laying in replacement and testing XLPE, insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor, 1100 volts grade, 3.5 core, cross sectional area 50 Sqmm, all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation laying poles, stay assembly and laying of LT/HT cables in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removal of excavated material(soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
Supply and laying sub class 'B' bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and as directed.
Sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be recorded for payment putpose..
On load change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps side handle, complete all as specified and directed.
Supply and fixing Aerial bunched cable (AB) LT of size 3 core- x16 sqmm+1-core x 16 sqmm + 1x25 sqmm for street lights. The 16 sq.mm. phase conductor shall be of aluminium solid round; outer diameter shall be within the limits.• The phase conductor shall be insulated with black weather resistant high-densitypolyethylene (HDPE) suitable to 1100 V insulation. The insulated conductors shall generally conform to the relevant standards.• Conductors: The properties of the aluminium wires before stranding shall be:• Tensile strength not less than 90 N/Sq.mm.• Resistivity at 20 Deg. C not exceeding 0.02845ohm / Sq.mm / m(V) and one bare messenger wire shall be stranded non compacted circular aluminium alloy conductor including taking down complete all as specified and directed. Make Havells, Gloster,Polycab,KEI Note:- The following hardware fittings and accessories shall be used to install,erect and join the AB cable (i) Suspension clamp with eye hook (ii) Suspension fittings and corresponding eye hook (iii) Dead eye fittinngs (iv) Nylon Tie (v) connectors
Taking down old unsv burnt cable of any description & providing multistranded copper cable single core size 1.5 sqmm required for street light connection, complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm, RCC cover 1:2:4 type B1 of size 45x45x6 cm reinforecd with 6mm dia mild steel bar @ 100mm c/c, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. Note:- The required resistance of Earthing shall be less than 3 ohm, If not found to the required resisstance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
Data overide by sms facility that work as per sunrise or sunset trigger or as per twilight with astro control longitude & latitude based.along with lux controller
Parameters can be set remotely using SMS queries- like Output mode, Offset Hrs, UV, OV settings• Can remotely override relay output using SMS query Energy Meter Functionality Parameter like Load current, Supply voltage, Power, Energy can be known remotely • With the help of “Auto Error Code Update” onsite error can be retrieved remotely during output event
Manual mode operation of entire System even incase of availibility of single phase present in the system.
Having tripping on over & under voltage, Over Load, dead Phase faults. These faults send to the operator and alert the operator to override the system.
Auto/Auto on/Auto off As per user defined program settings, Instant ON up to next Auto Event and Instant OFF up to next Auto Event.
Tiny Onboard Indication for TX-RX, Network, Power Indication and kwh pulse.
Surge Suppressor to protect the PLC Modules form Harmful spikes and lightning.
Supply voltage – 110-240 vac, 50/60Hz, 160-240 vac 3Phase 4 wire { P-N }, 50/60Hz, supply variation – 20% to +15%, Storage Temperature -10 C to+60C, Operating Temperature – 10C to + 50C, Switching Contacts – 9 No, 8A { resistive load } @ 240 VAC and 5A { resistive, load } @ 30 VDC, Power reserve { for clock only } 1000h, Clock deviation - ± s1 per day over the operating temperature range, DST – settable, EMI / EMC Radio Interference Suppression – CISPR 14-1 Class B, ESD – IEC 61000-4-2 Level III, Electrical Fast Transients, IEC 61000-4-4 Level IV, Surges – IEC 61000-4-5 Level IV, Voltage Dips & Interruptions – IEC 61000-4-11 All 7 Levels.
Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sectionsincluding nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed andinclusive of one primer coat, oneunder coat and one finishing coat of paint complete all as specified and directed.
Steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping and also write the pole No on the surface of pole, complete all as specified and directed.
Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete of poles complete all as specified and directed.
Cement concrete type C-1 1:3:6 (20mm graded crushed stone aggregate) as in copings of poles and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed.
Dismantling of old unsv PCC poles any size incl taking out embeded portion in PCC and making good disturbed ground complete all as specified and directed.
Taking out LT cable of size 16 Sqmm 4core from trenches/wall/poles and setting aside for re- use of serviceable cable, complete all as specified and directed.
Re-laying of old serviceable cable as obtained from item No-18 above as in trenches, or fixed to wall/poles, complete all as specified and directed.
Taking down old unsv HPSV/CFL/LED security lights fittings including GI brackets from external security poles complete all as specified and directed.
Supply installation testing commissioning of 70 watt LED flood light built in die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting complete with all accessories pre wired and making connection with copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-JETAALBAFLOODLIGHT70W or Equivalent cat part of make as specified in Appx 'F' here in after.
Supply, installation, connecting electrically and testing of street light junction box size 450x250x300mm, pole mounted made out of CRCA sheet 2 mm thick, powder coated having door with magnetic lock complete with bus bar 4 Nos suitable for 3 phase 4 wire supply system, made of aluminium strip of size 20x3mm including fixing arrangement made of MS Clamps of requisite size nuts, bolts and washers complete all as specified and directed.
Supply, fabrication and fixing feeder pillar box of size 500x450x500mm made out of MS sheet of 315mm thick bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated aluminium bus bar (length of bus bar not less than 40 cm) 4 Nos, making holes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and lenght of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping, from one of the makes as specified in the List of makes enclosed at Appx 'A' complete all as specified and directed.
Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 25 sqmm 3.5 core complete all as specified and directed.
Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 16 sqmm 4 core complete all as specified and directed.
GI pipe light grade 50 mm bore for cable protection fixed on poles with fixing clamps, nuts & bolts or laid in trenches/ floor/ passing through ducts etc complete all as specified and directed.
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drwan through and including rigid PVC conduit of size 25mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexibe, PVC insulated, unsheathed, multistranded, 1100 volts grade, FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note: Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Supply installation testing commissioning of 80 watt LED flood light built in die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting complete with all accessories pre wired and making connection with copper flexible cable of suitable size to light fitting complete all as specified and directed. Make:-Havells Cat Part No:-JETAALBAFLOODLIGHT80W or Equivalent cat part of make as specified in Appx 'F' here in after.
DWC HDPE tubing 25mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
DWC HDPE tubing 40mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
DWC HDPE tubing 50mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate.
MMS heavy duty PVC rigid pipe of size 25 mm having thickness 2mm thick (ISI marked) fix to walls or lay on floor for cable protection, complete all as specified and directed.
MMS heavy duty PVC rigid pipe of size 40 mm having thickness 2mm thick (ISI marked) fix to walls or lay on floor for cable protection, complete all as specified and directed.
Vertical distribution board TPN 4 ways (IP-43) with built in bus bars, neutral links, blanking plates double door suitable for FP MCCB as incommer and out going SP/TP MCBs, complete all as specified and directed. Make:- Havells cat part No-DHDLVDRWGOFO04 or Equivalent cat part of make of Legrand / Indoasian / L&T
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, including blanking plates where required. , complete all as specified. Make:-Havells cat part No-DHDPSHODPW12 or Equivalent cat part of make of Legrand / Indoasian / L&T
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 08 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, including blanking plates where required. , complete all as specified. Make:-Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make of Legrand / Indoasian / L&T
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 04 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning, including blanking plates where required. , complete all as specified. Make:-Havells cat part No-DHDPSHODPW08 or Equivalent cat part of make of Legrand / Indoasian / L&T
MCCB 63 Amps, 4 Pole, 415 Volts, 50 Hz, 16 KA, adjustable thermal & fixed magnetic, complete all as specified and directed. Make:-Havells cat part No-IHDA3BBF0063 or equivalent cat part of make-Legran / INDOASIAN / L&T
MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series, complete all as specified. Make:-Havells cat part No-DHMGCSPF006-032 or equivalent cat part of make-Legran / INDOASIAN / L&T
M/S JIWAN SINGH
Usha Engineering Co.
kailu construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .