Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | ₹32.7 L | L1 | Accepted-AOC Accepted Being Lowest Bidder |
| 2 | L2₹33.9 LRejected-AOC PLOT NO 60 PHASE II HOUSING COLONY DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹33.9 L | L2 | Rejected-AOC Rejected not being lowest bidder |
| 3 | L3₹35.6 LRejected-AOC | ₹35.6 L | L3 | Rejected-AOC Rejected not being lowest bidder |
| 4 | L4₹35.7 LRejected-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | ₹35.7 L | L4 | Rejected-AOC Rejected not being lowest bidder |
| 5 | L5₹36.8 LRejected-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹36.8 L | L5 | Rejected-AOC Rejected not being lowest bidder |
| Sl No | Description | Qty | Unit | K S BUILDERS L6 | SAHIL SHARMA L3 | PARAS RAM ASGOTRA AND SONS L1 | M/S SHUBAM ENGINEERS L2 | SARDALIA CONST CO L7 | MAHADEV ENTERPRISES L4 | ANIKET TRADERS L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolitions floor hearth or wall tiling including cement mortar bedding removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. | 150 | Sqm | 6 ₹900 | 10 ₹1,500 | 10 ₹1,500 | 2 ₹300 | 10 ₹1,500 | 10 ₹1,500 | 11 ₹1,650 |
| 2.00 | Dismantling of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed | 8 | Cum | 36 ₹288 | 300 ₹2,400 | 10 ₹80 | 30 ₹240 | 200 ₹1,600 | 100 ₹800 | 200 ₹1,600 |
| 3.00 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and as directed. | 12 | Cum | 56 ₹672 | 50 ₹600 | 50 ₹600 | 35 ₹420 | 200 ₹2,400 | 100 ₹1,200 | 200 ₹2,400 |
| 4.00 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 2.5 | Cum | 56 ₹140 | 600 ₹1,500 | 100 ₹250 | 40 ₹100 | 200 ₹500 | 100 ₹250 | 200 ₹500 |
| 5.00 | Dismantling of cast iron or AC or PVC drain pipes including all fittings and accessories, 100/75 mm dia and in any position complete all as specified and as directed. | 300 | RM | 26 ₹7,800 | 10 ₹3,000 | 10 ₹3,000 | 2 ₹600 | 10 ₹3,000 | 5 ₹1,500 | 1 ₹300 |
| 6.00 | Dismantling unuserviceable PVC overhead water tanks 1000 Ltrs capacity and removing away complete all as specified and as directed. | 8 | Each | 26 ₹208 | 200 ₹1,600 | 10 ₹80 | 50 ₹400 | 50 ₹400 | 50 ₹400 | 111 ₹888 |
| 7.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified and as directed. | 20 | Each | 16 ₹320 | 5 ₹100 | 50 ₹1,000 | 10 ₹200 | 40 ₹800 | 50 ₹1,000 | 11 ₹220 |
| 8.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each complete all as specified and as directed. | 15 | Each | 16 ₹240 | 5 ₹75 | 50 ₹750 | 15 ₹225 | 40 ₹600 | 50 ₹750 | 11 ₹165 |
| 9.00 | Taking down shutters of any description not exc 1 Sqm each complete all as specified and as directed. | 2 | Per Leaf | 16 ₹32 | 5 ₹10 | 20 ₹40 | 3 ₹6 | 40 ₹80 | 20 ₹40 | 11 ₹22 |
| 10.00 | Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and as directed. | 5 | Per Leaf | 16 ₹80 | 5 ₹25 | 20 ₹100 | 5 ₹25 | 40 ₹200 | 20 ₹100 | 11 ₹55 |
Updated dates
Tender Value
₹43.2 L
EMD Value
₹86,500
Closing Date
5 Feb 2026, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
SPL REPAIRS TO BLDG NO P-15 A OF 970 AD WKSP AKASH UNDER GE ARMY DHAR ROAD
2026_MES_747644_1
8071/NIT-87/2025-26
Open Tender
Civil Works
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹86,500
Yes
7 Mar 2026
8 Jan 2026
7 Feb 2026
9 Jan 2026
5 Feb 2026
23 Jan 2026
Demolitions floor hearth or wall tiling including cement mortar bedding removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed.
Dismantling of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling of cast iron or AC or PVC drain pipes including all fittings and accessories, 100/75 mm dia and in any position complete all as specified and as directed.
Dismantling unuserviceable PVC overhead water tanks 1000 Ltrs capacity and removing away complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each complete all as specified and as directed.
Taking down shutters of any description not exc 1 Sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and as directed.
Taking down shutters of any description not exc 1 Sqm each and refixing in same opening complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening complete all as specified and as directed.
Brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
Brick work with sub class 'B' bricks,old size, straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and as directed.
Factory made, 2nd class hard wood,35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass / gauge etc. (without sash bars) edges of framing plain, chamfered or rounded fitted with cut or mitered beads for securing glass etc. size of members of shutters as specified in applicable SSR complete all as specified and as directed.
Factory made, 35mm thick 2nd class hard wood, plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick ( style ) consisting of frame made out of mild steel tubes for top and bottom rails . Mild steel frame shall be covered with heat moulded plain cover PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side and gap insert for top rail and bottom rail ; Paneling of plain colour PVC sheet to be fitted in the mild steel frame welded /sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement supplying and fixing in the frame at site as per specification mentioned in relevant applicable SSR complete all as specified and as directed.
Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification mentioned in relevant applicable SSR complete all as specified and as directed.
S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and as directed..
Aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
Butt hinges 100mm long, Extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type C 21 complete all as specified and as directed.
Butt hinges of medium weight cold rolled mild steel 100 mm size and fitted to wooden or steel frame complete all as specified and as directed.
Mild Steel 300mm long ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and as directed.
Aluminium handles cast type, anodised, 150mm size complete all as specified and as directed.
S&F for 100 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed..
S&F in repair brass Chromium Tubular Towel rail 20mm dia, D type, 60cm long between flanges of brass chromium plated, fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and as directed.
S & F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and as directed..
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing; frame work for water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and as directed.
S&F for expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixed with galvanized steel staples supplied and fixed complete to wood or steel member, weight exc 4 kg per Sqm complete all as specified and as directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all complete all as specified and as directed.
S&F Steel ventilators with top hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all complete all as specified and as directed.
Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate including filling hollow portion of frame with plain cement concrete type C0 (1:3:6 ) (using 12.5mm graded stone aggregate) complete all as specified and as directed.
50 mm thick Plain cement concrete type C2 ( 1:3:6)( using 20 mm graded aggregates) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in laying of floor finishes and finishing smooth and even without using extra cement complete all as specified and as directed.
Non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:4) complete all as specified and as directed.
Glazed ceramic coloured tiles 300x250x 7mm thick on vertical surfaces such as dado/skirting ,set and jointed in neat cement slurry and pointed in white or coloured cement to match, fixed over and including 10mm thick rendering in CM (1:4) backing of wall tiles complete all as specified and as directed.
Mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to grade Fe-410-W(Gde-E-250) quality-B complete all as specified and as directed.
Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Taking down existing tarfelt including PCC, any thickness, including plastering and leeping (whether full thickness removed or only a part there of) complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface incl Brushing neat cement slurry with 3.0kg of cement per sq. metre finish ever and smooth (w/o using extra cement) incl WPC as per user manual at any height etc. (WPC will be measured and paid separately) complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for Roof treatment for Non Accessible Roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm, Top surface of roof after carrying out treatment as specified here in above as per manufactur instructions complete all as specified and as directed.
M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment complete all as specified and as directed.
M&L for 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) for roof pedding, finish even and smooth without using extra cement complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
Rendering 15 mm thick on fair faces of brick work or cement concrete surfaces of wall in cement mortar 1:4, finished even and smooth without using extra cement including mixing of water proofing compound complete all as specified and as directed (Note: Supply only Water Proofing compound shall be measured and paid for separately)
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement motar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
10mm thick cement plaster on brick or concrete surfaces, as in ceiling / facia / chajja etc. in cement mortar 1:3, finished even and smooth without using extra cement, including dubbing coat of plaster/ zero size PCC for filling broken portion complete all as specified and as directed.
S & F Sheet glass ordinary quality and glazing with oil putty in square n. exc 0.50 Sqm in each pane 4mm thick complete all as specified and as directed.
Description all as per item No 49 above but frosted glass complete all as specified and as directed.
Taking up or down steel tubing with connections for cleaning or refixing or removing to store yard complete of bore 15mm, complete all as specified and as directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete of bore 20mm, complete all as specified and as directed.
S & F 15mm bore steel water tubing medium grade galvanised with all fittings such as elbows,tee,socket,bends,nipple,union including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete all as specified and as directed.
S & F 20mm bore steel water tubing medium grade galvanised with all fittings such as elbows,tee,socket,bends,nipple,union including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete all as specified and as directed.
S&F in repair Bib taps, long body, fancy type, chromium plated with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore dia of pipe 15 mm ,complete all as specified and as directed.
S&F in repair Stop valves/Angle valve 15mm bore dia or pipe, cast copper alloy, screwed down, high pressure, fancy type, chromium plated with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm long complete all as specified and as directed.
S&F in repair Brass chromium plated shower rose 125 mm size with CP armwith or without swivel joints, any size including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair Vitreous china squatting pan of Orissa Pattern size 580x 440 mm white with ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC 1:7:12 type E-1 and finishing the top surfaces to match with the existing flooring complete all as specified and as directed.
S & F Vitreous china premium/ 1st quality wash down water closet EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete all as specified and as directed.
S&F in repair vitreous china wash basin white Oval type (fixed in granite slab) of size 550 x 400 including brackets, including cutting for and pinning in ends of bracket or erecting stand and fixing of waste pipe etc complete all as specified and as directed.
S&F in repair CP Pillar tap, fancy type chromium plated with crutch or butterfly handle screwed down high pressure with or without letterd hot or cold with long screed shanks and fly nuts screwed for iron pipe all complete all as specified and as directed.
18 to 20mm thick for Granite (of any type) work (table rubbed and polished) in steps, jambs,pillars, window-cills, cooking plat-forms and like in cement mortar (1:4) incl pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including screed bed or bedding layer of mortar 20mm thick in cement mortar 1: 4 for laying floor finishes complete all as specified and as directed.
S&F in repair Stainless steel Soap dish fixed to plugs with chromium plated brass screws, complete all as specified and as directed.
S&F in repairs for PVC valveless, with top button double action type,syphonic action type flushing cistern, 10 litres capacity, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe, complete all as specified and as directed.
S&F 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and as directed.
-'ditto all as per ser item No 67 above but laid in trench or in floor complete all as specified and as directed.
S&F 110mm bore PVC bends/junction any radius complete all as specified and as directed. .
S&F 110mm bore PVC bends/junction with access door any radius complete all as specified and as directed.
S&F 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.. .
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. .
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and as directed.
-'ditto all as per ser item No 73 above but laid in trench or in floor complete all as specified and as directed.
S&F for 75 mm bore PVC bends/junction any radius complete all as specified and as directed.
M&L for Complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, with sanding pad of 80 grit having dia 7"/9" to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and as directed.
Material and labour for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1 to 2mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc by skilled labour as per following steps :- Step 1 - Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute. Step 2 - Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3 - Allow 6-8 hrs time to dry the putty surface complete all as specified and as directed.
Material and labour for one coat of acrylic water based exterior grade primer @0.9 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and as directed.
Material and labour for two coats of water based premium acrylic smooth exterior emulsion of approved coulur with silicon addictive & color stay technology excellent dirt pick up resistance with low VOC less than 50 gram/ltr as per the LEEDS specification anti algal propertiess in two coats @ 1.79 ltrs (undiluted)/10sq mtrs diluted with water as per manufacturer instruction applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 m. the spray machine should be of reputed paint manufacturer as mentioned in PS and accessories for applying emulsion should be able to spray in hard to reach areas and penetration of emulsion on the surface using auto roller for making the surface uniform complete all as specified and directed. Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and as directed.
Material and labour for one coat of acrylic water based interior grade primer @0.8 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.and capable of operating single spray gun with a max material hose length of 30 m. The spray machine should be of reputed paint manufacturer as mentioned in PS. Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and as directed.
Material and labour for applying two coats of oil bound distemper using airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 m. the spray machine should be of repeated paint manufacturer as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface using auto roller for making the surface uniform complete all as specified and directed Note :- Sanding of surface to be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to be carried out before primer and paint application complete all as specified and as directed.
M&L for preparing new decorated plastered surfaces of ceiling including cornices, pilastered etc. by brooming down or steel wire brushing, scraping down existing colour surface smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying one coat of oil bound distemper (approved colour/ shade) complete all as specified and as directed.
M&L for preparing old decorated plastered surfaces of ceiling including cornices, pilastered etc. by brooming down or steel wire brushing, scraping down existing colour surface smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying one coat of oil bound distemper (approved colour/ shade) complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on wooden new surfaces of any description over 10cm width or girth incl preparation of new surfaces complete all as specified and as directed.
M & L for two coat of synthetic enamel paint over one coat of red oxide/zinc chromiume on steel surface including preparation of new steel surface width or girth exc 10cm complete all as specified and as directed.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and as directed.
S&F in repairs for rotational moulded polyetheylene water storage tanks (three layered and food grade white colour) (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed repair in position including 20 mm dia float valve, dismantling existing water tank complete all as specified and as directed.
S&F in repairs for 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. .
S&F in Repair vitreous china urinal half stall type suitable size white including all fittings complete (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc brushing neat cement slurry with 3.0kg of cement per sq. metre, complete all as specified and as directed.
M&L, for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed With grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over complete over 20 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes etc. complete all as specified and as directed.
Machine cut kota stone slab 18-20 mm thick in riser of steps, skirting,dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete fixed over and including 10mm thick rendering in CM (1:3) as backing layer, complete all as specified and as directed.
Dismantling of AC corrugated/CGI sheet , any gauge, thickness, including Nainital or similar pattern roof coverings all complete all as specified and as directed.
S&F pre painted galvaliume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.complete all as specified as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 290 grade E-165 complete all as specified and as directed.
Plain Cement concrete 1:5:10 type E-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete work complete all as specified and as directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc complete all as specified and as directed.
Material and labour for Point wiring complete (for simple and modular type ) with 1.5 sqmm single core PVC insulated heavy duty ISI Marked,FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC white non metalic PVC conduit heavy duty not less than 20mm dia with all accessories like tee, straight joint, L Bend etc.,concealed on walls, sufrace on ceiling/ floors etc., and including provision of PVC heavy duty Insulated FRLS copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal sunken box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., for the following:-
One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch complete all as specified and as directed..
One switch socket outlet point 3 pin 5 Amps on Independent board complete all as specified and as directed..
One switch socket outlet point 3 pin 5 Amps on same board complete all as specified and as directed.
Material and labour for Point wiring complete with 2 run of 2.5 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including suitable size of PVC white non metalic conduit with all accessories like tee, straight joint, L Bend etc., concealed on wall surface on ceiling / roofs etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 2.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches/socket outlets 15 Amps complete all as specified and as directed.
Supply and fixing socket outlet 5 Amp 230 volt ISI Mark complete all as specified and as directed
Supply and fixing Switch , single pole, one way 5 Amp 230 Volt ISI Mark complete all as specified and as directed
Supply and fixing socket outlet 16 Amp 230 volt ISI Mark complete all as specified and as directed
Supply and fixing switch , single pole, one way 16 Amp 230 volt ISI Mark complete all as specified and as directed
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and as directed.
S&F Wall mounted Mirror light LED fitting, 10 Watt, 2 Feet long incl integrated electronic driver complete all as specified and as directed.
Supply and Fixing LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb complete all as specified and as directed.
Supply & fixing in replacement of industirial wall mounted plug socket suitable with IP 44, 3 pin and neutral and earth socket (3P+N+E) complete with , 240 volt, complete all as specified and as directed .
M & L for sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 6 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments including PVC conduit and draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles complete in all respect all as specified and as directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FRLS PVC insulated and PVC conduit 25 mm dia shall be measured and paid as one unit length
Supply & Fixing V TPN Distribution with and including 160 amp MCCB 4 pole 25 KA, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 04way, confirming to IS 13032 & 8623 complete all as specified and as directed.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12way, confirming to IS 13032 & 8623 complete all as specified and as directed.
Supply & Fixing MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and as directed.
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and as directed.
S&F energy saviing environmental friendly, long life exclusive innovative die-cast aluminium IP-66 option for 3000K, 10 KV Surge protection device included ,LED flood light of 120 Watt with high power LED toughened glass and high power LEDs and secondary lenses complete all as specified and as directed.
S&F LED building security light 120 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and as directed.
Disconnecting and taking down and opening the exhaust fan of size 450mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution, repainting exhaust fan with blades and replacing the unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, etc., assembling Exhaust fan and refixing in the original place connection and testing complete all well complete all as specified and as directed.
Disconnecting and taking down and opening the Wall fan of size 600 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution, repainting wallt fan with blades and replacing the unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, etc., assembling Exhaust fan and refixing in the original place connection and testing complete all well complete all as specified and as directed.
Supply & fixing wall mounted air circulator fan 230 volt single phase oscillating 600 mm sweep including taking down old air circulator fan and deposit to MES store complete all as specified and as directed.
Taking down Old unserviceable rusted earthing plates complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32mm x 6mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed.
S&F Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and as directed .
Supply and laying XLPE cable 185 x 3.5 core complete all as specified and as directed.
supply and laying XLPE cable 95 x 3.5 core complete all as specified and as directed.
Excavation in trenches in Hard and dense soil n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of poles,cable laying etc, including forming bottom surface to required level and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in soil/loose soil including spreading, leveling,watering & well ramming in layers not .exceeding 25 cm thick complete all as specified and as directed.
Removing of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punning down complete all as specified and as directed.
Material and labour cover to underground cable with one layer of bricks using sub class 'B' bricks laid flat acorss the cable complete all as specified and as directed.
Supply , installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of ize 1.2 M X 1.1 M X 0.5 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 50mmX20mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-1000A, with & including CTs 1000/5 type-01 Set. (d) MCCB 630Amp,4 Pole 50 KA , with adjustable thermal setting -1NO (e) MCCB 315 Amp 4 pole 25/36 KA with adjustable thermal setting -2Nos (f) MCCB 200 Amp 4 pole 25/36 KA with adjustable thermal setting -1Nos (g) MCB SPN 63 Amp - 3 Nos (h) Space for provision of 4 pole MCCB 200 Amps 16 KA- 01Nos complete all as specified and as directed.
Supply and installation, testing and commissioning as in repair Outdoor type LT panel board made out of CRCA MS sheet of size 0.90 M X 0.75 M X 0.40 M not less than 3.0 mm thick, front & back openable (CPRI approved) including cutting,shearing, shaping, bending,welding, drilling, threading etc,supported on base frame made out of MS angle of size 50 mm X50 mm X 6 mm welded with & including 4 Nos MS angle legs of size50 mm X50 mm X 6 mm not less 900mm high ,grouted in PCC 1:3:6 type C-1 factory made out of ,duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer , with suitable locking arrangements with & including Aluminium Bus Bar duly encased in & including colour coded FRP Sleeves of size 40mmX10mm mounted on SMC/DMC red insulators Insulator (RYBN) complete all as specified and as directed by Engr-in-Charge comprising of the following accessories :- (a) Voltmeter flush mounted 0-500 V square digital type -01 No. (b) Ammeter flush mounted 0-250A,with & including CTs 500/5 type-01 Nos. (c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 125 Amp 4 pole 10KA with adjustable thermal setting -1NO (e) MCB SPN 63 Amp - 12 Nos (f) Space for provision of 3 Phase Electric Meter- 02 Nos (g) Space for provision of 4 pole MCCB 63 Amps 16 KA- 01Nos complete all as specified and as directed.
Deduct Schedule of Credit of Rs. (-) 109208.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tender_87.pdf
Tender Documents • 2.24 MB
BOQ_837254.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid