Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
16 Jan 2023, 6:00 pmClosed
AGE(I) AF Memaura
AGE(I) AF Memaura
REPAIR MAINTENANCE REPLACEMENT OF INTERNAL WIRING MCBS DBS FITTING AND FIXTURES AT DOMESTIC AREA AT 505 SU AF STN MEMAURA
2022_MES_559307_2
8265/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
AGE (I) AF Memaura
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE(I) AF Memaura
₹15,000
Yes
10 Feb 2023
20 Dec 2022
18 Jan 2023
20 Dec 2022
16 Jan 2023
27 Dec 2022
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket power) complete of any size, type and including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good to the disturbed surfaces of walls, floors, etc to match with the existing surfaces complete all as directed.
Material and labour for point wiring concealed type with 1.5sq mm PVC insulated unsheathed single core multistranded FRLSH copper conductor cable 1100 volts grade incl. 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. medium grade PVC rigid conduit not less than 20 mm dia with its accessories, galvanized pressed steel terminal boxes of thickness 1.0 mm covered including 3mm thick laminated sheet cover for fixing switches/ socket/regulators etc for the following: - Note:- (i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit/PVC Casing caping and its accessories. (ii) The quoted rete is deemed to be included for the chases cutting. (iii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
One light/fan/exhaust fan/ Bldg security light point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
All as per item No. 2.00 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
Material and labour for point wiring in PVC casing and caping type with 1.5sq mm PVC insulated unsheathed single core multistranded FRLSH copper conductor cable 1100 volts grade incl. 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. ISI mark suitable size PVC casing and caping with its accessories, PVC terminal boxes of thickness 1.0 mm covered including 1mm or more thick PVC cover for fixing switches/ socket/regulators etc for the following: -
One light/fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
All as per item No. 9.00 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
M&L for point wiring with FRLSH PVC insulated, PVC unsheathed cable, single core, stranded, copper conductor cable 1.5 sqmm size, drawn into and including concealed PVC conduit not less than 20mm dia with 1.5 Sqmm unsheathed, stranded copper conductor cable as earth continuity conductor, sunken galvanized pressed steel terminal boxes of thickness not less than 1.0 mm of required module complete with frame plate and cover plate of required module for mounting modular switches, sockets etc. complete all as specified & directed for the following :- Note:- (i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit/PVC Casing caping and its accessories. (ii) The quoted rete is deemed to be included for the chases cutting. (iii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
One light/fan/exhaust fan/ bldg security lights point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
All as per item No. 15.00 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
S&F switch modular type 5/6 Amps, 230 V AC, single pole, one way complete all as specified and directed.
S&F switch piano modular flush type 16/20 Amps, 230 V AC, single pole, one way complete all as specified and directed.
S&F socket out let multipurpose modular for 2 pin and 3 pin, 5 Amp flush type with shutter complete all as specified and directed.
S&F Modular bell push type 5/6 Amps, 230 V AC, single pole, one way complete all as specified & directed.
S&F socket outlet, multipurpose, modular 6 pin, 6 /15Amp with shutter complete all as specified and directed.
S&F modular Fan step regulator, 120W - 2 module.
S&F switch piano, flush button single pole, one way 6 amp.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F bell push, flush type, 6 amp 240 volts complete.
S&F switch flush type, 6 amp, single pole, two way complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F ceiling rose 63 x 25 mm three terminals complete.
S&F door bell, ding dong/ multi music, AC, 240 volts, single pole complete.
S&F angle holder, insulated polycabonate body with back plate complete.
Supplying and fixing in replacement hum free electronic 4 step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
S&F in renewal LED bulk head luminaire, internally prewired with and including premium quality diffuser for glare free light and easy to install samp fit installer complete with all accessories power consumption < 10 watt luminaire lumen >1000 lm, luminous efficiency > 100 lumens /watt,LED Make : Nichia/Cree/Everlite/Eclison/Osram Ltd with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.95, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.50 Sqmm and fixing arrangement for fixing the light fitting complete all as specified and directed.
S&F square slim surface mounted LED down lighter of capacity 15 watts, 240 volts, white powder coated pressure die cast aluminium housing and bottom frame with high transmitive LGP technology, high efficiency non yellowing PMMA diffuser, complete with LEDs driver and accessories pre-wired upto terminal block lumens wattage not less than 15 watts, luminaire lumen output >1500 Lm, ingress protection IP-20, ambient temperature 0-450 C driver efficiency more than 85% power factor above 0.95, Surge protection 3 KV multi stage isolated constant current and variable working votlage 15-0270 Volts complete all as specified and directed.
All as per item no 38 above but of 09 watt capacity and output lumen >900 Lm.
Supply and fixing 10 SQMM 2 Core Aluminium unarmoured, flame resistant PVC flat cable all as specified and directed.
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 9 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fixing decorative LED lighting fixture with extruded aluminium, heat sink, environmental friendly, energy efficient ready to use suitable for 4' LED tube complete all as specified and directed.
Material and labour for sub main wiring with 10 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, ISI marked, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade, ISI marked complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
All as Item NO 43 above with 06 Sqmm nominal cross section area
All as Item NO 43 above with 04 Sqmm nominal cross section area
Supplying and fixing powder coated, CRCA steel sheet MCB distribution board with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required of following ratings & ways including taking down existing DBs:-
SPN, 240 volts, 4 ways.
SPN, 240 volts, 8 ways.
SPN, 240 volts, 12 ways.
TPN, 415 volts, 4 ways.
Supplying and fixing tripple pole and neutral, powder coated, CRCA steel sheet, Vertical type MCB distribution board suitable for MCCB incomer upto 125 amp, 8 way, 415 volts, degree of protection IP 43 with metal door, recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required.
Supplying and fixing 20 amp, single pole and neutral, industrial type socket outlet, with 2 pole and earth, metal enclosed plug top in powder coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 20/32 amp as required.
Supplying and fixing MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 32 amp.
SPN 06 to 32 amp.
SPN 40 to 63 amp.
TPN 25 to 63 amp. Note for MCBs & MCB DBs:- MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces.
Supply and fix in replacement of MCCB, 63 Amp, 04 Pole, AC, 415 volt of 16 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supplying and fixing MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete.
S&F LED batten 4 Ft surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W , luminaire lumens >2000 lm, luminous efficiency > 100 lumens /watt, LED make : Nichia/Cree/Everlite/Eclison/Osram Ltd with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.95, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with operating voltage range 150-270V AC and safety for extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.75 Sqmm and fixing arrangement for fixing the light fitting complete all as specified and directed. .
S&F LED batten, 2 Ft surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 10W luminaire lumen >1000 lms, luminous efficiency > 100 lumens /watt, LED make : Nichia/Cree/Everlite/Eclison/Osram Ltd with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.95, THD <10% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with operating voltage range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.75 Sqmm and fixing arrangement for fixing the light fitting complete all as specified and directed.
S&F in renewal 2ftx 2ft recess mounted full panel LED luminaire with white powder coated housing as heat sink and frame in CRCA sheet , high efficiency LED grade diffuser, in built electronic driver duly wired up to terminal block, power consumption < 36 watt luminaire lumen >3500 lm, luminous efficiency > 120 lumens /watt,LED make : Nichia/Cree/Everlite/Eclison/Osram Ltd with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.95, THD <10% as per IEC 61000-3-2, colour temp - 5700K, surge protection 3 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.50 Sqmm and fixing arrangement for fixing the light fitting complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore medium grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete after dismantling unserviceable earthing (above GL only) complete all as specified and directed.
Supply and lay, jointing & testing of cable XLPE armoured LT 1100 volt grade heavy duty with Stranded aluminium conductor passing through ducts/pipes and run on poles/walls including fixing with proper size of alluminium lugs/saddles and taking down old cable of the following sizes.
6 Sq mm 2 Core.
10 Sq mm 2 Core.
Taking down ceiling fan /Exhaust fan /cabin / wall fan/ table fan / pedestal fan from fan hook and disconnection from ceiling rose and dismentling of ceiling parts i.e. down rod and connector / condenser nut bolts, rubber bush (garari) condenser carrier clip (PVC) in build connector two way complete servicing by cleaing greasing/ oiling bvefore in side surface by CTC with sand paper and repair and re-fitted the same position and testing incl writing MES No of fan and refixing, complete all as specified and directed on site.
Dismantling of ceiling fans /exhaust fan /cabin /wall fan/ table fan / pedestal fan AC single phase 230 volts (collected from MES fan store) any make / model except old vintage, dismantled its stator,rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish as aproved by Engineer - In - charge cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and deposited to MES store after testing complete all as specified and directed for the following type of fans:
Ceiling fan of size 1200/1400mm sweep
Exhaust fan of size 300/375mm sweep
Exhaust fan of size 450mm sweep
Wall/cabin fan of any sweep
Pedestal fan of any sweep from 450 upto 600mm
Table/pedestal fan upto 400mm sweep
M & L for replacement of the following items in repairs :
Gun metal bush for ceiling fan of any make & sweep.
Ball bearing of size 6201/6202/6203/6204 for ceiling /wall /pedestal /cabin /table Exahust fan of any make and sweep. Make : NBC /SKF / TATA.
Rotar shaft for fan.
Condenser 2.5 MFD for fan as required
Condenser 3.15 MFD for fans as required
Condenser 4.0 MFD for fans as required
Flexible wire of size 23/0.0076 twin core copper conductor
Flexible wire of size 40/0.0076 three core copper conductor
MS clamps for down rod complete with nut, bolt and rubber pad, split pin and washer for ceiling fan of any size & make.
Fan blades with screws, nuts and washers for ceiling fans of any make and sweep as required at site.
Supply and replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long 19 mm outer dia with holes on both ends of the rod for connection wire replacement complete.
Supply and replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete.
Fan blades with screws, nuts and washers for ceiling fans of any make and sweep as required at site.
Taking down the existing ceiling fan and deposited to the MES store and S & F Ceiling Fan ( fancy type) 1200 mm sweep, 230 volts, AC,5 star rating complete with all accessories and down rod all as specified and directed .
S&F condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S/F Blade Set with frame & four legs of fan with coupling for 300 mm (12") sweep exhaust fan all as Specified and directed.
S/F Blade Set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan all as Specified and directed.
Supply and fixing louvers for 300 mm sweep exhaust fan all as specified and directed.
Supply and fixing louvers for 450 mm sweep exhaust fan all as specified and directed.
Supply and fixing fasteners having 10mm dia bolt for fixing exhaust fans or similar items complete all as specifed and directed.
Taking down the Geyser of any make and 50 Ltr capacity size horizontal or vertical from Site for repairs/overhauling/replacement of unserviceable parts (Repairs/replacement of parts Shall be measured and paid separately) including De-scaling cleaning and re-assembling alongwith replacement of old nuts and bolts with washers heavy duty including disconnection of electric supply, water supply lines and refixing the the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line all as specified and directed. Note:- Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers.
All as per item No. 96 here-in-above but Geysers of capacity 25 ltrs .
S & Fixing in replacement of heating element of Geyser (ISI marked) of capacity 2.0 KW for any make and type all as specified and directed.
S&F in replacement Thermostat (ISI Marked) suitable for any type, make and capacity of geyser complete all as specified and directed.
S & F in replacement of unserviceable indicating lamps red and green colour for Geysers any make complete all as specified and directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser including dismantling of old unserviceable bottom cover complete all as specified & directed.
Supply and replacement of unserviceable door assembly suitable for 25 ltr capacity, ISI marked comprising of inlet and outlet thermostate, housing with gasket complete with bolts, nuts, washers, screws of packing suitable for any type and make of geyser complete all as specified and directed.
All as per item No.103 here-in-above but Geysers of capacity 50 ltrs .
S&F metallic plug top suitable for 20 Amp capacity complete all as specified and directed.
S & F in repair Stainless steel inner tank 25 Ltrs capacity, ISI mark of as per existing gauge for Geysers of any make as approved and directed.
S&F in replacement of brass Safety Valve heavy duty ISI marked for any type and make of Geyser suitable for 15 mm bore of pipe complete all as specified and directed.
S&F in replacement PVC connection heavy duty 15mm dia 45 cm long with PTMT nuts complete all as specified & directed.
S&F in replacement flexible steel connection heavy duty for hot water supply of 15mm dia 45 cm long with PTMT nuts complete all as specified & directed.
S&F PVC insulated multistranded copper conductor cable 3 core of size 2.5 Sqmm 1100 volts grade complete all as specified & directed. Make:-Havells/Plaza/Finolex, Polycab/Paragon.
S&F bib taps 15 mm bore chromium plated fancy type screwed down for iron pipe or for brass ferrule complete all as specified & directed.
Dismantling complete solar water heating system of capacity 300 LPD per day including hot & cold water pipes and hot water tank complete. Repairing the system fixing back in position and testing complete all as specified and as directed. Note:- Rates quoted by the contractor shall deemed to be included for:- (a) Making good the worn out missing nuts bolts, washers, union sockets, flanges and screws etc . (b) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube throughly cleaning the complete panel, making the tubes scale free, and re-assembling the panel. (c) Cleaning hot and cold water tanks. (d) All other materials shall be measured and paid separately under respective items.
All as per item No 112 here in before but of capacity 100 LPD
NAVSURAJ CONSTRUCTION AND INFRADEVELOPERS
Ashirwad Contractor and Supplier
VINAYAKA (INDIA) MULTIFARIOUS SERVICES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .