Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.3 L
EMD Value
₹4,700
Closing Date
22 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE JAl Shakti Shimla Rural Division at Sunni
EE JAl Shakti Shimla Rural Division at Sunni
Submersible mono block pump and Laying 125mm pipe for laying rising main of booster stage
2025_HPIPH_123363_1
SNN-SML-003-740-Tdr-25-22-32dt 10.12.25
Open Tender
Civil Works - Water Works
Item Rate
90 days
EE Sunni
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
EE Suni
₹4,700
22 Jan 2026
11 Dec 2025
22 Dec 2025
11 Dec 2025
22 Dec 2025
11 Dec 2025
11 Dec 2025 - 22 Dec 2025
Description
Booster Stage.
Providing and installation of Mono submersible pump set of 7.5 HP of Kirloskar/KSB make conforming to IS :9034-1976 alongwith directly coupled submersible type squirrel cage electric induction motor suitable for operation on 230 volt. 1 phase 50 C.P.S.A.C.supply with water lubricated bearing and provided with pivoted segment type thrust bearings to with stand non vertical lead with minimum wear and tear and duly fitted with device to take upto the expension of water with heating of motor complete in all respect including entire carriage of material upto all leads and lifts (Make KSB/Kirloskar) .
(I) Discharge (Q):- 36.00 m3/h or 10.00 LPS.
(ii) Total Head: - 20 Meters.
laying and jointing of GI Pipe in trenches to be levelled to grade, IS pipes of following diameters conforming to IS/ISO 1239:2007 (Latest with upto date ammendments) having minimum wall thickness as specified below of GI Pipe jointed with butt welding and detailed specifications including all short pieces, bends, tees and other specials etc. made from parent tubes as per site conditons including flushing, cleaning and hydraulic testing complete to the best satisfaction of the Engineer-in-charge. The laying of pipes should conforming to IS: Code 5822-1970 within all leads and lifts complete in all respects.
GI Pipe 125 mm dia (MG) P/E RD 0 TO 100
Providing fixing and jointing of M.S.flanges conforming to BIS-6392-1971 (latest with upto date ammendment ) flange dia, table and nominal pressure as specified below welded at both ends of pipes leak proof at an interval of 100 mtrs.(as per site condition for particular reach as required) according to relelvant BIS Code 816-1962 and provided with nuts and bolts of required size as per BIS code 1364 including 3mm thick compressed asbestos fiber gasket of synthetic rubber gasket conforming to relevant BIS code 2712-1965 complete in all respect including all leads and lifts.
125 mm dia Table-5
Providing and fixing copper 2.5 mm2 sqmm PVC insulated and PVC sheathed ,armoured power cable /industrial cable for submersible pump and motor (approved make)
Supply and fixing of control panel for 3HP mono submersible pump complete with shaft and angle iron, fabricated duly painted and complete with internal wiring and comprising of air break starter main switch of suitable amp. T.P. volt meter ameter phase indicating lamps water level guard and single phase preventor including entire carriage of material upto all leads and lifts.
Providing double flanged (Swing type) Cast iron Reflux valve of Pelcian/ Leader/Bhel/Kirloskar/ Kilburn/GLED/ Fouress/Kartar make having bye pass arrangement for delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments.- REFLUX VALVE:- i)Make: NIT/Pelcian Class: PN 1.00 Seat Pressure:- Material:-
125mm dia PN-1.00
Manufacturing and fixing of common header of required size from the parent tube of GI Pipe with butt welding,cutting and grinding etc and required fitting etc. at site to support the submersible pumps of booster stage i/c all leads and lifts.
Deployment of Mechanaical excavator (JCB) machine for removal of debris, boulder & slip and and for diversion of river coarse etc. from source point in Khad/ river to make sufficient space for lowering of Mono submersible pump and construction of reservoir of suffcient capacity within the khad/river i/c all leads and lifts.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.19 MB
FORM-8.pdf
Tender Documents • 0.67 MB
terms.pdf
Tender Documents • 0.10 MB
BOQ_181206.xls
BOQ • 0.34 MB
FORM6.pdf
Tender Documents • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .