Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.7 L+₹1.4 L (7.96%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹19.3 L+₹2.0 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹19.8 L+₹2.5 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹19.9 L+₹2.6 L (15.0%)Rejected-Finance | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 May 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/REPLACEMENT TO UNSV CHLORINE DOSING PUMP SET/CHLORINE PLANT, WATER LEVEL INDICATOR, LT PANEL AND OTHER CONNECTED WORKS OF WATER SUPPLY SYSTEM AT EAST OF MG ROAD UNDER GE E/M LUCKNOW
2022_MES_521797_1
GE/EM/LKO/EXT(WS)/T-24 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
240 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹60,000
Yes
18 Jun 2022
4 May 2022
28 May 2022
4 May 2022
26 May 2022
21 May 2022
Amount
Taking down chlorine metering pump 1/2 HP 240 Volt, 50 Hz and transporting from pump house to contractor's work shop or at site, dismantling for carrying out necessary repairs / renewal of parts of motors or pump as per existing make and model and reassembling complete chlorine metering pump sets & installation ,testing etc the same after necessary repair to site complete all as specified and directed. Note:- (i) New spares/parts shall be measured & paid separately under appropriate items listed here-in-after. (ii) Quoted rate shall be deemed included of transporting, repair, overhauling and replacement of spares complete.
Supply and replacing (in repairs) pump shaft for metering pump complete all as specified and directed.
Supply and replacing (in repairs) spring for metering pump complete all as specified and directed.
Supply and replacing (in repairs) diaphragm for metering pump complete all as specified and directed.
Supply and replacing (in repairs) dozing head for metering pump complete all as specified and directed.
Supply and replacing (in repairs) tubing suction / delivery pipe 3/8 " dia nylon PVC 03 mm thick for metering pump complete all as specified and directed.
Cutting out the existing winding metering pump electric motor of any make single phase, 240 Volts, AC of any make, rewinding with the same size of coper winding wire as exisiting complete all as specified and directed.
Supply and replacing (in repairs) of nylon braided PVC pipe 15 mm bore complete all as specified and directed.
Supply and replacing (in repairs) chlorine testing kit stand type complete all as specified and directed.
Supply and replacing (in repairs) brass nipple complete all as specified and directed.
Supply and replacing anti siphon valve of metering pump and make the serviceable complete all as specified and directed.
Supply and replacing (in repairs) connecting nut 3/8" with adopter for dosing pump complete all as specified and directed.
Supply and replacing (in repairs) rotor assembly with bearing brackets and tolerance rings complete all as specified and directed.
Supply and replacing (in repairs) pump head ( ferrule 1/4" and duckbill included) complete all as specified and directed.
Supply and replacing (in repairs) roller assembly complete all as specified and directed.
Supply and replacing (in repairs) Pump tube (roller type) complete all as specified and directed.
Supply and replacing (in repairs) injection check valve 3/8" complete all as specified and directed.
Supply and replacing (in repairs) weighted suction line strainer 3/8" complete all as specified and directed.
Supply and replacing transformer oil di-electric strength not less than 60 KV/MM from oil immersed starter of any rating situated in any sub station located in Cantt duly heated upto the required tempereture complete all as specified and directed.
Supply of liquid chlorine sodium hypochlorites (Grade-I) drinking water with 9% chlorine contents by volume conforming to IS-11673 in sealed non-chemical re-actined / oxidation LDPE containers of 60 Kg PVC tanks, as required on monthly basis with manufacturer's chlorine test certificate and manufacturer's date marked not more than 02 week ago complete all as specified and directed.
Supply only high strength calcium based granular containing appropriate quantities of chlorination dipensates / corrosion inhibitors to prevent encrustation / scaling in distribution system in 45 / 50 Kg packing of having chlorine contents 65% to 70% by volume approved and tested from Govt lab or equivalent testing agency (not more than 02 months old packing) complete all as specified and directed.
Supply only bleaching powder the chlorine intent form 30-35% chlorine powder or chromate lime, used for water treatment complete all as specified and directed.
Supply only O-tolodine chlorine solution in packing of 500 ml bottles for testing of chlorine contents in water, complete all as specified and directed.
Supply only rubber / PVC hand gloves to handle chlorine / liquid complete complete all as specified and directed.
Supply only PVC flexible non toxic hoses( off white) of 40mm outer dia, in standard length of 30 M roll complete all as specified and directed.
S&F in replacement GEARMOTOR assy complete 230 Volt 50 Hz, complete all as specified and directed.
S&F in repacement Pump head (ferrules 1/4" & DUCKBILL) assy complete all as specified and directed.
S&F in repacement single head feed rate control with shaft assy complete all as specified and directed.
Supply and fixing in replacement of the water level indicator of OHT upto 25m head and 90 mtr apart from the tubewell complete kit in all manners as Approved by E-in-C's Br, AHQ including taking down of old unserviceable spares: IE Co, or equivalent of Servel/ Surya Electronics & Control complete all as specified and directed.
S&F cable joint kit suitable for 0.5 Sq mm 10 pairs of copper wire cable of water level indicator complete all as specified and directed.
Supplying, laying or fixing, jointing and testing solid PVC insulated, 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts garde 0.5 sqmm instruemental cable ISI-5608 marked ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including taking out unserviceable cable complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items.
Repair/maint and overhauling of L.T Panel 3 phase AC 415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp. meter,phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel paint after 01 coat iron red oxide paint along with replacement of nuts, bolts, thimbles, gasket etc as per site requirement including complete testing as per site requirement. Note : All spare parts and rewinding work will be measured and paid seperately under respective item of Sch 'A'. are as under:-
Supply and fixing in repair, connecting, testing and commissioning MCCB 100 Amps , TP , 415 Volts, rupturing capacity 16 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fixing in repair, connecting, testing and commissioning MCCB 125 Amps , TP , 415 Volts, rupturing capacity 16 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fixing in repair, connecting, testing and commissioning MCCB 160 Amps , TP , 415 Volts, rupturing capacity 36 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fixing only on load changeover switch in open execution 4 pole, 415 V, 50 cycles-100 Amp, complete all as specified and directed.
MCB TPN capacity 32 Amps, 415V, 50 C/S 10 KA complete all as specified and directed.
MCB SPN capacity 32 amp, 'C' series complete all as specified and directed.
S&F MCB single pole 5 to 30 amp rating 'B' Series 240 Volt complete all as specified and directed.
Set of indicating lamp (Red, Yellow & Blue) LED type, complete all as specified and directed.
Single phase preventor relay as in repair, complete all as specified and directed. Make: L&T/Minilac/C&S or any other equivalent
Supply and fixing cast iron Sluice valve PN-1.6 flanged ends suitable for 150 mm bore including jointing material complete all as specified and directed. Make : Zoloto/Leader/ BIR/ Upadhaya
commercial construction
Shree Kanth Technologies
MTR GROUP & COMPANY
SWASTIK ENGINEERS
Magneoflux
M/s Acme Engineers and Contractors
FUTURE Inc.
M/s Sanjay and Sanjay
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .