Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC MOHALLA NALAPUR NARNAUL MOHLLA NALAPUR 123001 | NARNAUL | MAHENDERGARH | HARYANA | 123001 | ₹1.8 Cr | L1 | Accepted-AOC Lowest Rate |
| 2 | L2₹1.9 Cr+₹4.3 L (2.36%)Rejected-AOC 28 29 GALI NO 05 MAHABIR PARK 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | ₹1.9 Cr+₹4.3 L (2.36%) | L2 | Rejected-AOC High Rate |
| 3 | L3₹1.9 Cr+₹9.4 L (5.19%)Rejected-AOC | ₹1.9 Cr+₹9.4 L (5.19%) | L3 | Rejected-AOC High Rate |
| 4 | L4₹2.4 Cr+₹59.0 L (32.4%)Rejected-AOC | ₹2.4 Cr+₹59.0 L (32.4%) | L4 | Rejected-AOC High Rate |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
14 Dec 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer, PH.Engg. Division No.2 Narnaul
AUGMENTATION OF DRINKING WATER SUPPLY SCHEME CANAL BASED FOR 122 NO. VILLAGES at 40 LPCD TO 70 LPCD IN NARNAUL TEHSIL, DISTRICT MOHINDERGARH. Construction of 12 Clear water tanks, 2 staff quarters, extension of 12
2020_HRY_150379_1
EIC Pkl NO. 81053-PHE/Prog.dated 17-09-2020
Open Tender
Civil Works
Works
365 days
Narnaul Juriduction
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹3.4 L
Yes
22 Mar 2021
23 Nov 2020
14 Dec 2020
23 Nov 2020
14 Dec 2020
23 Nov 2020
Amount
Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame IBS - 1 Koriawas 400 LPM X 40 M. Head (7.50 BHP)
IBS - 2 Basirpur 2000 LPM X 40 M. Head (30.00 BHP)
400 LPM X 40 M. Head (7.50 BHP)
SBS (SUBSIDIARY BOOSTING STATIONS ) 400 LPM X 40 M. Head (For SBS Koriawas-I & II, Hasanpur-I, Rambas-I & II, Kultajpur-I, Basirpur-I, Amarpur Jorasi-I & Karoli-I
500 LPM X 40 M. Head (For VBS Maroli-I)
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items For 2 no Pumping Sets of 400 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 400 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.1.1
For 2 no Pumping Sets of 2000 LPM x 40 m Head a) Main switch 200 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 2000 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.2.1
For 2 no Pumping Sets of 400 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 400 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.2.2
For 2 no Pumping Sets of 400 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 400 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.3.1
For 2 no Pumping Sets of 500 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1.3.2
Supply, erection, testing IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc. i) 6mm2 3core
ii) 10mm2 3core
iii) 16mm2 3core
iii) 25mm2 3core
Sluice Valves / NRV & specials for Pumping Machinery Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make) 100 mm i/d
Supplying, fixing of CI swing check type reflux (non returned valve) PN 1.6 of IVC/VAG make 100 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. 100 mm i/d
Supply, erection, fixing & testing of CI Double flanged pipe complete with all jointing materials 100 mm i/d
Sluice Valves/ Specials For Rising Mains Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make) For Rising main lines 150 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. 150 mm i/d
Supply erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. (for SBS)
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all resct (6 at IBS-1 & 2 = 6 )
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect for various Pump Chambers (6 at IBS-1 & 2 = 6 )
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification.
Bidder Name
Amount
Devinder Kumar Contractor(GSTN-06CEEPK3098C1ZN)
M/s Shree Jagdamba Ji Tubewells Narnaul(GSTN-06AGIPK1100H1Z0)
suresh kumar(GSTN-06AIPPK4333B1ZJ)
SUKHBIR SINGH CONT(GSTN-NA)
M/s Shree Jagdamba Ji Tubewells Narnaul
SUKHBIR SINGH CONT
Devinder Kumar Contractor
SUKHBIR SINGH CONT
suresh kumar
Devinder Kumar Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .