Tender Value
₹49.7 L
EMD Value
₹99,388
Closing Date
3 Jun 2025, 3:00 pmClosed
Executive Engineer
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
SITC of VRV/VRF AC in SPS, Security and Establishment Units, IIT Delhi
2025_IIT_861746_1
IITD/WORKS (SP-5007)/2025
Open Tender
Miscellaneous Works
Works
90 days
Indian Institute of Delhi Hauz Khas
As per tender documents
11 documents required · 11 mandatory
₹0
₹99,388
20 Jun 2025
27 May 2025
4 Jun 2025
27 May 2025
3 Jun 2025
27 May 2025
Amount
OUTDOOR UNIT: Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor-based Controller, top discharge type condensing unit(s), with CFC & HCFC free Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Centigrade ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required (any additional refrigerant required due to long pipe lines shall be within the scope of contractor). The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Acceptable make: Daikin / LG / Blue Star / Toshiba / Carrier / O'General / Mitsubishi / Voltas)
SECURITY UNIT (not less than)
CENTRAL STORE (not less than)
ESTABLISHMENT SECTIONS (not less than)
INDOOR UNIT HIGH WALL TYPE: Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control with batteries, drain pan, necessary accessories etc. suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make of the indoor unit shall be same as outdoor unit as per item no. 1)
1.0 TR (Stores & Security)
1.3 TR (Stores & Security)
1.45 TR (CCTV, Security)
1.65 TR (Stores)
2.0 TR (Security)
CEILING MOUNTED ROUND CASSETTE: Supply, installation, testing and commissioning of following minimum capacity all direction flow round shaped (ceiling mounted cassette type) unit equipped with synthetic washable media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control with battery (cell) etc., suitable for operation on 230 V ± 10%, 50 Hz, ac supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS system. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 Degree C WB temperature.
1.6 TR (Establishment Section)
2.4 TR (Establishment Section)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF AC system, complete with fittings (including RefNet Y-joints), with suitable adjustable ring type hanger supports, jointing / brazing including accessories, cutting of glass window wherever required with proper finishing, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. packing of all leakage either on wall or window with silicon / insulation, as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro) Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam] NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The makes of tube fittings shall be same as that of tubes (4) The thickness of fittings used shall be same as that of the pipe (4) Y-joints / refnets as to be required at site are included with pipes
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
GI TRAY SUPPORT: Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended / supported from the ceiling / wall with GI suspenders including GI bolts and nuts, GI C-Channels, etc. including bends, reducers, Tees, cross-members as required, GI protective sheet covering (for outdoor portion) outside the room etc. as required.
225 mm width x 50 mm depth x 1.6 mm thickness
300 mm width x 50 mm depth x 1.6 mm thickness
150 mm width x 50 mm depth x 1.6 mm thickness
DRAIN / CABLE PIPE: Supplying and laying of ISI marked CPVC pipe of 25 mm dia for draining of sweated water / drawing communication cable from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. insulated with XLPE class - O tubular insulation / with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick etc. complete as required. (Acceptable make: Astral / Geroge Fischer / Finolex / Prakash / Supreme / Prince)
DRAIN PIPE: Supplying and laying of ISI marked flexible not less than 3 layered braided PVC pipe of 25 mm dia for draining of sweated water from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. wherever required etc. complete as required.
Supplying and laying of ISI marked FRLS industrial multistranded following type copper cable of following size of 1.1 kV grade conforming to IS694:2010 including making connection etc. for communication / indoor power supply between indoor and outdoor unit and other units, etc. (Acceptable make: KEI / Finolex / Polycab / Universal / Havells / Gloster / RR Kabel / Rallison) [NB: Single stranded cable not to be used]
2 core x 1.5 sqmm unarmoured alongwith hard PVC conduit not less than 20 mm alongwith bends, tees etc. of make Astral / Supreme / Finolex / Prakash / Prince.
3 core x 2.5 sqmm unarmoured
4 core x 16 sqmm armoured
Supplying and making end termination with brass compression gland and tinned copper lugs for following size of pvc insulated and pvc sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
4 core x 16 sqmm armoured
3 core x 2.5 sqmm armoured
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / power cable as required.
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (but without MCB/RCCB/Isolator) (Acceptable make: Havells / Siemens / L&T / Legrand / ABB / Schneider / C&S / HPL / Hager)
12 Way, Double door
8 Way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Acceptable make: Havells / Standard / HPL/ Legrand / L&T / Polycab / C&S / ABB / Siemens / Schneider)
Single Pole
Double pole (as incomer to DB)
Supplying and fixing cable end box (loose wire box) suitable for 12 / 16 way double door SPN MCB DB on surface / recess complete with testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 5 -10 amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (Acceptable make: Havells / Standard / HPL/ Legrand / L&T / Polycab / C&S / ABB / Siemens / Schneider)
Providing and fixing following rating and breaking capacity and pole MCCB Conforming to IS/IEC 60947-2 & IEC 60947-2 with thermomagnetic release and terminal spreaders in sheet steel enclosure including drilling holes, duly factory painted as required, making connections, providing spreader terminal, rotary handle, etc. as required. (Acceptable make: Siemens / L&T / GE Power / C&S / Crompton / Havells / Legrand) For main power connection.
63 A, 18 kA, TPMCCB
Fabricating, Providing and fixing M.S. iron frame fabricated with M.S. C-channel of size 50 mm x 50 mm x 6 mm (thick) for resting the condenser unit on the roof / floor of the building duly supported from the bottom as required including painting and grouting the framework with cement concrete etc. complete as required. (Acceptable make of angle: SAIL / Jindal / TATA / Prakash / Nezone)
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation (of VRF Outdoor Unit) etc including form work etc as required.
Supplying and fixing of 4 Module surface mounting, non-metallic MCB Distribution board, dust and water protected, transparent sheet with spring-operated auto-closure, din bar for mounting MCBs with 40/50/63 amp TP MCB including making connections, etc. for outdoor unit power serving etc. complete as required. (Make: Grasp / Legrand, MCB make: Havells / Standard / HPL/ Legrand / L&T / Polycab / C&S / ABB / Siemens / Schneider )
SUB HEAD - 2 (AMC) (Supplementary agreement shall be formed after DLP) under ARMO Fund Comprehensive (Routine, Preventive and Breakdown) maintenance of 14, 18 & 20 HP VRF / VRV Type AC unit including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units during the defect liability period of 1 year after date of commissioning as per maintenance schedule. (No payment shall be made separately for this period): 1st Year : 01 Job
Comprehensive (Routine, Preventive and Breakdown) maintenance of 14,18 & 20 HP VRF / VRV Type AC unit including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units after defect liability period of 1 year from the date of commissioning as per maintenance schedule. Any breakdown shall be attended within 4 hours of reporting. Spare parts required during breakdown maintenance including PCB cards, Compressors, etc. shall be arranged and replaced by the Contractor. This is applicable for the whole system of AC units installed. (N.B.: 01 Job means during a period of one year)
2nd year (For 12 months)
3rd year (For 12 months)
4th year (For 12 months)
5th year (For 12 months)
6th year (For 12 months)
M/S COOLREF ENGINEERS (BID ID -3223423)
SMD Solutions (BID ID -3225204)
Utility Services (BID ID -3224855)
TRANSCEND CONTRACTS PVT. LTD. (BID ID -3223365)
JUHI AND JAI CONTRACTORS PVT LTD (BID ID -3225357)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .