Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹31.8 L+₹74,890 (2.41%)Rejected-AOC | L2 | Rejected-AOC Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹34.3 L+₹3.2 L (10.2%)Rejected-Finance | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | Rejected-Technical 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | - | Rejected-Technical Technically disqualified. |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
14 Oct 2022, 2:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Construction of Administrative Building for SDO Chanchal and other Departmental Offices at Chanchal, Malda (Electrical works) - SITC Split AC Machines
2022_WBPWD_401998_1
WBPWD/EE/MED/e-NIQ-11/2022-23
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
Chanchal
Please refer Tender documents.
6 documents required · 6 mandatory
₹66,000
23 Dec 2022
5 Sept 2022
17 Oct 2022
6 Sept 2022
14 Oct 2022
9 Sept 2022
Amount
Supply & Delivery of following Split type AC machine suitable for operation from Single Phase 230Volt, 50 Hz AC Supply with energy efficient Rotary type compressor, Star rating- 3 to 5 star, Condenser and evaporator- Copper Coil , Refrigerant : R32/ R410A including loading , unloading charges at work sites. [The warranty will be considered from the date of Installation and commissioning.(Make- O-general).Necessary Test Certificate will provided at the time of delivery of the Machines.]
i) 2 Ton [ Daikin / Hitachi / Mitsubishi / 'O' General ASGA 24 FUTC]
ii) 1.5 Ton [ Daikin / Hitachi / Mitsubishi / 'O' General ASGA 18 FUTC]
Installation, Testing & commissioning of Split AC with appropriate mounting kit (Air Conditioner Outdoor Unit Heavy duty Mounting Bracket ) & Testing of whole Refrigerant system with all joints valve etc. Including leak testing, flushing at different time by dry N2 incl. Supply & filling of refrigerant gas.(for Split AC only)
Supply & Installation of copper refregrent pipe (Make-Carrier / Mandeg / Mexflow / Totaline) (3/8'',5/8'') line with kenofone insulation and tape, jointing materials etc. as per direction of EIC.
Supply and laying 1.1 kv grade 4 core 4 sqmm stranded unarmoured copper cables ( Make- RR Kabel / Havells / Polycab)
Supply & Installation flexible water pipe size of 19mm including clamping arrangements. (Make - Supreme/Astral)
Supply & fitting and fixing of 32mm dia PVC hard pipe including necessary socket, bend ,Tee, nipple ,cross , clamp etc. for drainage water properly as per direction of EIC.(Make- Supreme / Oriplast / Astral)
Supply of 4.0 TR capacity floor standing(Tower) Air Conditioner machine of rated cooling capacity of 48000 BTU/hr (13.5KW) with 1/2 Nos. compressor (Rotary/Twin Rotary/Scroll), Rated power supply-415V(+/-5%)-3ph-50Hz. , Copper Condenser, Air-flow:-1200CFM. Refrigerant gas R410A/R32 (Make: Bluestar / Hitachi / Carrier / Mitshubishi Electric / Daikin / Voltas) - Warranty for AC machines incl Compressor-3 years from date of commissioning.
Installation of 4.0 Tower AC machine on floor with MS Base Square shape painted including making hole on wall and fixing out door unit on suitable MS strauture on wall, making gas and liquid line connection, electric cable connection and drain pipe connection, making hole on wall, mending good to damages.
Supply & installation of Easy to bend, Corrossion free Annealed Copper refrigeration pipe line complete with fitting, elbows, bends, supporting arrangement (G.I. saddle) on wall.
a) Liquid Line (9.52 mm OD with 0.6mm thick)
b) Suction line (19.05mm OD with 0.7mm thick)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carrige ,for Installation of outdoor Unit of AC machine (G+3 Building) per storey of building per vertical run.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate for AC machine will have to be submitted during delivery of the material.
M/S. M. R. ENTERPRISE
GITANJALI ELECTRONICS AND ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .