Loading…
Loading…
Tender Value
₹49.0 L
EMD Value
₹97,975
Closing Date
31 Aug 2026, 3:00 pm
REGISTRAR
GOA UNIVERSITY TALEIGAO PLATEAU GOA
Annual Operation and Maintenance of STP and Sewage Pumping stations and Maintenance and repairs of water supply and sewerage network in university campus during 2026-2027
2026_GU_31153_1
GU/9/2026-2027/Engg and Tech Div/137
Open Tender
Civil Works - Water Works
Item Rate
GOA UNIVERSITY TALEIGAO PLATEAU GOA
PLEASE REFER TENDER DOCUMENTS
4 documents required · 4 mandatory
₹4,000
₹97,975
18 Aug 2026
18 Aug 2026
1 Sept 2026
18 Aug 2026
31 Aug 2026
19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Clearing jungle including uprooting of rank vegetation, grass, bush, wood trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level & removal of outside the periphery of the area cleared. | 2,300 | SQ.M | 1.25 | ₹2,875 |
| 2 | Operation and maintenance of sewerage pumping stations, cleaning of sewage sump and septic tank once in six months including removal and disposal of sludge etc. all complete. The scope of this item includes engaging pump attendants and sewer man and minor materials needed for day to day running and operation of activities connected with sewage disposal on all days including Sundays and holidays ( only pipes and valves & cost of pump repairs if required will be borne by University) | 12 | MONTH | 11 | ₹132 |
| 3 | Operation of sewage treatment plant at Faculty Block E including removal and disposal of sludge etc. complete. The scope of item includes engaging pump attendants for day to day STP running and operation activities in three shifts (round the clock) and the minor consumables such as oil,grease,Hypochlorine required for STP unit, on all days including Sundays and holidays.(Cost of repairs of pipes and valves & cost of any major repairs such as mechanical/ electrical repairs, replacement of media if required will be borne by University) | 12 | MONTH | 10 | ₹120 |
| 4 | Supply Testing and Commissioning of Unique SNR IP DMS Electronic 3 phase panel with Water level controller, Single phase preventer, Dry run protection Ammeter/Volt meter having manual and bypass mode inclusive of 02 nos. Niagara make float switches and 125 meters of 1.5 sq.mm 3 core electric cable complete. | 3 | job | 100 | ₹300 |
| 5 | Supply Testing and Commissioning of Niagara make water level controller single phase panel with Water level controller, Single phase preventer, Dry run protection Ammeter/Volt meter having manual and bypass mode inclusive of 02 nos. Niagara make float switches and 125 meters of 1.5 sq.mm 3 core electric cable complete. | 1 | job | 53 | ₹53 |
| 6Providing and placing on the roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to IS 12701; 1996 inclusive of P/F G.I tank connector of required size. SHAKTI/ SINTEX make | |||||
| 6.01 | b) 500 litres capacity | 5 | NO | 10 | ₹50 |
| 6.02 | c)1000 litres capacity | 8 | NO | 10 | ₹80 |
| 7Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer. External work. | |||||
| 7.01 | I SCH-80(blue)/(white) | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
Tendernotice_2.pdf
PDF • 0.17 MB
Tendernotice_3.pdf
PDF • 0.19 MB
BOQ_31554.xls
BOQ • 0.50 MB
CPWD6_merged.pdf
PDF • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].