| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC Technically and financially eligible L1 Bidder | |
| 2 | L2₹26.9 L+₹3.2 L (13.6%)Rejected-Finance MIG 105 DR R P NAGAR PHASE 02 KORBA CG 495677 | KORBA | CHHATTISGARH | 495677 | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹27.0 L+₹3.3 L (14.0%)Rejected-Finance AT SAMALEI VIHAR PANCHGACHHIA PO BARAIPAH | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹28.2 L+₹4.6 L (19.3%)Rejected-Finance AT NANDINI ROAD BHILAI CHHATTISHGARH 490001 | BHILAI | CHHATTISHGARH | CHHATTISHGARH | 490001 | L4 | Rejected-Finance Not L1 Bidder | |
| 5 | L5₹28.9 L+₹5.2 L (22.1%)Rejected-Finance 404 ANKUSH PLAZA TEKA NAKA CHOWK KAMPTEE ROAD NAGPUR 440017 | NAGPUR | MAHARASHTRA | 440017 | L5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹49.8 L
EMD Value
₹62,400
Closing Date
7 Mar 2025, 5:00 pmClosed
Staff Officer (Civil) SECL Korba Area
Office of the General Manager, South Eastern Coalfields Limited, CIVIL DEPARTMENT, KORBA AREA KORBA- 495 677(CG)
Roof treatment with APP (First Floor Qrtrs 56 nos) including providing and placing PVC water storage tank after demolishing of damaged brick work tank and other miscellaneous works in 140 no DM Qrts at Rajgamar sub area under Korba Area.
2025_SECL_330085_1
SECL/GM/KA/C/e-Tender/24-25/72 dt.24.02.2025
Open Tender
Civil Works - Others
Item Rate
120 days
Office of the General Manager SECL Korba Area
As per NIT
4 documents required · 4 mandatory
₹62,400
30 Jun 2025
24 Feb 2025
10 Mar 2025
25 Feb 2025
7 Mar 2025
25 Feb 2025
25 Feb 2025 - 28 Feb 2025
Amount
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 25 mm nominal bore, 152mm long, weighing not less than 440 gms
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
CARRIAGE OF MATERIALS By Mechanical Transport including loading,unloading and stacking Lime, moorum, building rubbish Lead - 2 km
Dismantling & removal of old tarfelting from horizontal & vertical surface manually and disposal of the same within 50m lead as per instructions of the EIC
Removing the vegitation and cleaning over roofs, chhajjas, spouts, rain water pipes etc. and disposing the same within a lead of 100m including plants and other unserviceable materials.
Total impact of GST for the purpose of CTC
Shree Balajee Construction (BID ID -1135724)
NARENDRA KUMAR SINGH (BID ID -1134299)
Kailash Enterprises (BID ID -1136320)
DURGA ENTERPRISES (BID ID -1135860)
Water Proofers (BID ID -1136845)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_342197.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .