| 1 | L-1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L-1 | Accepted-AOC Lowest and Reasonable |
| 2 | L-2₹2.8 Cr+₹10.5 L (3.92%)Rejected-Finance 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | ₹2.8 Cr+₹10.5 L (3.92%) | L-2 | Rejected-Finance Other than Lowest |
| 3 | L-3₹2.8 Cr+₹14.6 L (5.44%)Rejected-Finance | ₹2.8 Cr+₹14.6 L (5.44%) | L-3 | Rejected-Finance Other than Lowest |
| 4 | L-4₹3.2 Cr+₹53.3 L (19.8%)Rejected-Finance | ₹3.2 Cr+₹53.3 L (19.8%) | L-4 | Rejected-Finance Other than Lowest |
| 5 | L-5₹3.9 Cr+₹1.2 Cr (45.3%)Rejected-Finance | ₹3.9 Cr+₹1.2 Cr (45.3%) | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹2.9 Cr
EMD Value
₹3.6 L
Closing Date
27 Dec 2021, 6:00 pmClosed
CWE (AF) Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
PROVISION OF COVERED PARKING APRON (CPA) WITH ANNEXES AT SATWARI JAMMU
2021_MES_492875_1
CWEAFJ-24/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Jammu
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹2,000
GE (AF) Jammu
₹3.6 L
Yes
5 Jan 2022
6 Dec 2021
29 Dec 2021
6 Dec 2021
27 Dec 2021
20 Dec 2021
Amount
B/R Portion
Surface Excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavating over areas not exceeding 1.5m deep and getting out in any type of soil, complete all as specified and directed.
Excavating over areas exceeding 1.5m but not exceeding 3.0m deep and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Plain Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed.
RCC M-25 (design mix) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Formwork to sides of concrete foundation, footings, bases of columns, rafts and raft beams and similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, complete all as specified and as directed.
TMT bars 10mm dia and over, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete, all as specified and as directed.
TMT bars 5mm dia and over as in stirrups, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete all as specified and as directed.
Rolled Mild Steel Sections as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, etc., conforming to Fe 410-W (Gde-E-250) qualiy A, complete all as specified and as directed.
Strutural Tubular Steel as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming to Fe 410-W (Gde-E- 250) quality-A complete all as specified and as directed.
Rolled Mild Steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Rolled Mild framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete, drilled for fixing of sheeting or other covering. Doors, etc, to be prepared for hanging or sliding with and includiing either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other convering, running rails and guides) and hanging, also fastening and fixing complete all as specified.
Mild steel framed works such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, including bending, cutting and welding as required, complete all as specified and as directed.
Mild Steel Bolts, machine made, with hexagonal or square head one end each screwed other end to be fitted with washers and one hexagonal or square nut, exceeding 10cm long but not exceeding 15cm long and dia of neck exceeding 16mm but not exceeding 20mm complete all as specified and as directed.
Mild Steel Bolts, machine made, with hexagonal or square head one end each screwed other end to be fitted with washers and one hexagonal or square nut, exceeding 22.50cm long but not exceeding 60cm long and dia of neck exceeding 16mm but not exceeding 20mm complete all as specified and as directed.
Bottom Wheel (for Hangar Gate) of size 200mm x 75mm with necessary arrangements like ball bearing, mild steel plates, nuts etc. for fixing the wheel complete all as specified and directed.
Top Wheel (for Hangar Gate) of size 100mm x 40mm with necessary arrangements like ball bearing, mild steel plates, nuts etc. for fixing the wheel complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, cladding of walls / gates, fixed with self taping screws, complete all as specified and directed.
EPE Foam packing for junction of galvalume sheeting using 40mm wide EPE foam filler of profile as per corrugation of galvalume sheet complete all as directed.
Butyle sealing tape 50mm wide 3mm thick, self-adhesive type, complete all as specified and directed.
100mm thick sandwiched Puf Panels (in walls) comprising of 0.45mm (BMT) thick galavalume pre-coated coloured sheets on both sides. The core shall be of PUF with density not less than 42Kgs/Cum complete all as specified and as directed.
Stainless Steel welded wire mesh for bird proofing fixed / welded to steel members. weight not exceeding than 2.5 Kg/Sqm complete all as specified and as directed.
Wind driven Roof Turbo Ventilator, internal throat dia 600mm with the top cover made of Stainless Steel 0.50mm thick (S.S-430) and the fins of the fan made of 0.35mm thick Stainless Steel (S.S-430), while the bottom ring along with all the internal fittings (except the Internal Shaft) made with 100% virgin Polypropylene (PP) of thickness not less than 3mm with self lubricating double ball bearing fixed on roof of hangar all as per manufacturer's instructions including making the complete fitting water tight complete as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
Rendering 5mm thick cement mortar 1:3 on concrete surfaces of ceilings finished even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound all as specified and as directed.
Hard core of broken stone gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and as directed.
150mm thick PCC 1:4:8, type D-1 (using 20mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and as directed.
25mm thick PCC 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate) as in floor, finished even and fair to receive floor finishes, complete all as specified and as directed.
Cement concrete work in pavement / hard-standing of flexural strength 40Kg/Sqcm in field using 400 kg of cement per cubic metre, thickness of concrete 200mm, complete all as specified and directed.
Supply only 12mm thick Recron 3S construction fibre all as specified and as directed. Notes : 1. Recron 3S construction fibre shall be mixed with concrete @ 900grams per Cum of concrete.
Three component epoxy polyurethane self leveling antistatic dissipative flooring system laid in overall thickness of min 3mm (Anti-Static in 5 x 5 metre grid) comprising of 200 microns thick priming coat followed by 2mm thick base coat and 1mm thick top coat complete all as specified and as directed. Notes : 1. Epoxy colour theme will be decided by GE in consultation with user. 2. Marking of yellow lines at designated place will be included in quoted rates. 3. The laying of the EPU flooring is to be done by only the Authorized Applicator of any of the listed brands in PS Clause 10.3.1 on Serial Page No 94 (R) and approval for the same is to be taken from the Garrison Engineer before start of work.
Cutting of 12mm wide expansion joints upto full depth of concrete slab (150 mm) (intial cut of 3 mm upto full depth cut by diamond cutter machine within 08 to 24 hours of casting) and filled with pre-formed compressible filler board (HD-100) of bottom 125 mm depth, provision of closed cell polythene backup rod 12 mm dia one coats of primer on vertical side of joints and sealing the joint (Top 10-12 mm) with single component polyurethane sealant conforming to requirement of BS-5212 and EN 141875-2003 for Hydrolysis/Water Resistance Test and applying masking tape on edge at joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied complete all as specified and directed.
Forming Construction Joint 25mm deep and 10 mm wide (using diamond cutter) providing polythene backup rod 12 mm dia and filled with polyurethane sealant single component (minimum depth of sealant 12mm) complying with BS 5212, BS 4254, end EN 41875-2003, priming the sides, minimum MAF ± 30% with ten years performance guarantee and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as per manufacturer' instructions as specified and directed.
Double charged Vitrified coloured tiles, dark shade of size 596mm x 596mm x 9 to 10mm thick as in floors etc. bedded & jointed in neat cement slurry over and including 10mm thick screed bed in cement mortar 1:4 and pointed in coloured cement to match the colour of tile all as specified and directed.
Double charged Vitrified coloured tiles, dark shade of size 596mm x 596mm x 9 to 10mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed in CM 1:4 as in Dado / Skirtings etc. jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified and directed.
Non-skid coloured glazed, joint free, ceramic tiles of any shade and any pattern of size (Pattern consists combination of two or more tiles) 400mm x 400mm x 7mm thick, over and including 10mm thick screed bed in CM 1:4 as in floors etc. jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified and directed.
Glazed ceramic coloured wall tiles in any type and in any pattern (Pattern consist of combination two or more diffrent colour tiles etc.) in vertical surfaces of size 600mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4, finished fair to received the tile, complete all as specified and directed.
20mm thick Granite stone (table rubbed and polished) as in wall lining (veneering to wall), steps, platform etc. and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of granite stone over and including 20mm thick screed bed in CM 1:4 finished fair to received the granite and rounding the exposed edges of the granite slab, complete all as specified and as directed.
75mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection etc., finishing surface even and fair without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete as specified and directed. Note : The concrete shall be laid at a stretch not exceeding 3.0m in length and joint shall be made at every turning / corners, complete all as specified and directed.
Precast cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in Kerb Stones etc. (of any section), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match set in CM 1:6, including necessary form work, complete all as specified and as directed.
100mm thick PCC 1:4:8, type D-1 (using 20mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and as directed.
Precast cement concrete coloured glazed interlocking tiles 80mm thick, M-50 grade, conforming to IS-15658 2006, any shade, colour and pattern laid over and including 20 to 30mm thick stone dust / sand cushioning laid dry to the profile including vibrating with surface vibrator after laying of tiles including budding and filleting joints etc. complete all as specified and directed.
Anodised Aluminium powder coated Frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Anodised Aluminum powder coated, Door Shutter, air tight, partly glazed with and including 5mm thick tinted glass and partly Panel with and including 12mm thick prelaminated particle with and including members top, bottom, vertical and middle of shutter made of size 82.55 x 44.45 x 1.50mm thick (minimum) including necessary cleats, glazing clips, 5 mm thick tinted glass, hydraulic door closer, rubber packing with anodised aluminum beading / glazing clips, size 19.00 x 17.30 x 0.70 mm, weight 0.097 Kg/RM of both side , all aluminum memeber and fitting should be ISI marked complete in all respect as per manufacturers instructions and as directed.
Note : The following fittings are to be provided and the cost of the same is deemed to be included in the Quoted rates :- 1. Stainless Steel Hinges 100mm size - 03 Nos 2. Stainless Steel Handles 200mm size - 02 Nos 3. Stainless Steel Tower Bolts 150mm size - 02 Nos 4. Brass Mortice Lock with 06 levers one number on each leaf.
Anodised Aluminum powder coated, Window, fixed type with three track (minimum 1.50mm thick) with three shutters made of 18mm x 40mm x 1.25 mm section (one for wire mesh and two for tinted glass) with rubber gasket beading and locking arrangement etc. complete all as specified and including 5.50mm thick tinted glass and stainless steel wire mesh of size 0.56 mm dia of wire and 1.40mm aperture including making good distrubed surface complete. All aluminium member and fitting shall be ISI marked and as per the manufuactures instructutions and as directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening etc., complete as specified and directed.
Factory made Solid Panel PVC Door Shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
Stainless Steel Butt hinges, medium weight, 100mm size, complete all as specified and directed.
Stainless Steel Barrel Tower Bolt complete of size 200mm long complete all as specified and directed.
Stainless Steel Handle complete of size 150mm long complete fixed in repairs complete all as specified and directed.
Stainless Steel, Sliding Door Bolt with hasp, staple (bolt type) 250mm, and fixing clips of sheet and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
25 mm dia stainless steel fancy type Curtain Rods fixed to brackets including fancy type corner ends and brackets complete all as specified and directed.
Suspended False Ceiling System using suspended ceiling grid sysytem with the size of grid as 605mm x 605mm with GI frame work, main runner 38 x 24mm, cross tee 38 x 24mm and wall angle 22.2mm x 22.2mm using 12mm thick semi-perforated particle board tile of size 600mm x 600mm suitable for insulation and accoustic purpose. The suspended ceiling system grid system shall be duly suspended by 4mm dia GI bar hangers from the purlins of the roof with butterfly clips complete, all as specified and as directed.
Rotational moulded polyethylene Water Storage Tanks of capacity 500 litres, (cylindrical vertical with threaded top), three layered, hoisted and fixed in position including supply and fixing necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, brass valve 20mm high pressure with polythene float and fly nut etc. complete, fixed in repairs, all as specified and directed.
Gun metal globe or gate valve with iron wheel heads, screwed both ends for 20mm dia bore iron pipe complete all as specified and directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 15mm, complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20mm, complete all as specified and as directed.
Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 25mm, complete all as specified and as directed.
Bib tap with long nose and wall flange cast copper alloy chromium plated, fancy type, with capstan Head handle, screwed down, screwed for 15mm bore iron pipe or for brass ferrule, complete all as specified and directed.
Stop cock / Angle valve with adjustable wall flange CP cast copper alloy, fancy type, with capstan head handle and adjustable wall flange, screwed down, high pressure screwed both ends for 15mm bore iron pipe or for unions, complete all as specified and directed.
Pillar taps, cast copper alloy, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, complete all as specified and as directed.
Brass chromium plated shower rose, fancy type, 125mm with swivel joints and fixed to steel pipe or union, fixed in repairs, complete all as specified and directed.
PVC connection 45cm long fitted with two Nos of brass checknuts and washers complete, fixed to 15mm bore iron pipes, complete all as specified and directed.
Vitreous china wash hand basin 520mm x 450mm, oval shaped of colour as approved fixed in granite top including 32mm bore brass chromium plated waste coupling with long screwed shank and fly nuts, PVC flexible waste pipe of bore 32mm and adequate length, 15mm bore PVC connection pipe 450mm long with brass nuts on both side, complete all as specified and as directed. Note : Granite top and RCC Shelf shall be measured and paid seperately under respective items.
Vitreous china wash down water closet pan (pedestal pattern) white, including ‘P’ or ‘S’ trap, white seat cover with flat bottom and mild steel CP hinging device, CP brass jet nozzle with 1500 mm long PVC pipe, complete all as specified and directed.
10 litres capacity PVC low level flushing cistern of approved make complete with PVC flush pipe and connection to water closet, complete all as specified and directed.
Vitreous china coloured urinal bowl, flat back of size 465mm x 355mm x 265mm (minimum) with C.P. flushing nozzle on top, grating and union for discharge pipe including PVC waste pipe, complete all as specified and directed.
Stainless steel Sink 1.0mm thick sheet of approved make with plug, washer & waste, including bedding cement mortar, overall size 495mm x 420mm, complete all as specified and directed.
Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms), complete all as specified and directed.
PVC (SWR) pipes single socketed, 110mm bore in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
PVC (SWR) pipes single socketed, 75mm bore in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
PVC (SWR) pipes single socketed, 75mm bore in any length with rubber ring joints, laid in walls complete all as specified and directed.
PVC (SWR) bend 110mm bore complete all as specified and directed.
PVC (SWR) bend 75mm bore complete all as specified and directed.
PVC (SWR) junction single (Single T) equal or unequal with access door bore of pipe 110mm complete all as specified and directed.
PVC (SWR) junction single (Single T) equal or unequal with access door bore of pipe 75mm complete all as specified and directed.
PVC (SWR) reducers bore of pipe 110mm complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
PVC (SWR) Vent cowl bore of pipe 75mm complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:4, complete all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping complete all as specified and as directed.
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc. and setting in mortar 1:6 complete complete all as specified and as directed.
Reinforced Concrete Pipes, class NP-2, laid & jointed complete with collars, bore of pipe 150mm, complete all as specified and as directed.
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested cement concrete 1:4:8 type D-2 (using 20mm graded crushed stone aggregate) for 150mm dia pipe complete all as specified and as directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses, complete all as specified and as directed.
Formwork to sides of faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in surface channel and drains complete all as specified as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and as directed.
HDPE drain channel with grating 100mm width and 50mm height suitable for external areas complete all as specified and as directed.
Septic tank with cover slab at GL of 25 users capacity with inlet chamber, brick work in cement mortar 1:4, M-25 (design mix) concrete in cover slab, internal plaster 20mm thick in cement mortar 1:3 using water proofing compound including necessary excavation and earth work in any type of soil, RCC precast manholes covers with angle iron welded frame, CI vent pipe 100mm dia with cowl complete all as specified and shown on Drg No CEAF/STD-15/2000 Sheet 1/2 & 2/2.
Soakage Well 3.0 metre dia and 3.0 metre deep below inlet (depth) from inlet pipe to ground level 45cm including excavation and earth work in any type of soil, PCC 1:4:8 type D-2 in foundation, RCC M-25 cover slab, wall in honey combed brick work in cement mortar 1:4, earth cushion on brick lining on top, filling with brick bats and inlet pipe 150mm dia complete all as specified and shown on Drg No CEAF/STD-15/2000 Sheet 1/2 & 2/2.
Preparation new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including a coat of wall care putty (Birla/JK) of average thickness 2 to 3mm, complete all as specified and as directed.
Preparation new plastered or previously untreated surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
Preparation new plastered surfaces of walls and applying two coats of cement base paint including one coat of cement primer complete complete all as specified and directed.
Preparation new plastered surfaces of wall and applying two coats of Exterior Emulsion (Weatherproof Paint) over a coat of primer complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of anti-rust paint (epoxy), over a coat of red oxide primer, complete all as specified and as directed.
E/M Portion
Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including concealed PVC conduit 20mm dia or more as per the site requirement including its fittings and fixtures such as ties, bends, elbows and junction boxes etc. including 1.50 Sqmm copper earth wire (green colour) FRLS Cable as earth continuity conductor connected to main earthing and common earth terminal for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sunken box and inner and outer plate for mounting of Modular Switches including cutting chases and making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 110 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 110 here-in-before but for one 5 pin socket outlet 05/06 Amp on same board, complete all as specified and as directed.
All as per the description of Serial Item No 110 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 4.0 Sqmm copper conductor (in green colour) for as earth continuity conductor all as specified and directed.
Modular switch 1 way 06 Amps, 1 module, complete all as specified and as directed.
Modular Socket, 06 Amps, 2/3 pin combined 2 module, complete all as specified and as directed.
Modular switch 1 way 16 Amps, 1 module, complete all as specified and as directed.
Modular Socket 6/16Amps, 2/3 pin combined 2 module, complete all as specified and as directed.
Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
Modular electronic Fan Regulator, 2 module, 230 Volts, 120 Watts complete all as specified and directed
Triple Pole and Neutral enclosure with a Three Pin and Earth Plug and socket complete with one single pole 32 Amp MCB, 415 Volts complete all as specified and directed
Tube light fitting, batten type suitable for and including LED 20 tube Rod 4' long with decorative colour in aluminum housing and integrated electronic driver and all accessories pre-wired and making connections with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connector to light fitting complete all as specified and as directed.
Tube light fitting, batten type suitable for and including LED 10 tube Rod 2' long with decorative colour in aluminum housing and integrated electronic driver and all accessories pre-wired and making connections with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connector to light fitting complete all as specified and as directed.
Bulk head luminaries energy saving, surface mounted, decorative bulk head back-lit LED luminaire complete with all accessories suitable for and including 1 x 10 Watts LED lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 Volts 50 Hz complete all as specified and as directed.
Surface mounting powder coated white CRCA full glow LED panel functional and decorative luminare suitable for hang on bird proofing LED light fitting 42 watts complete with, connector block all accessories prewired with suitable size cable including connecting electrically using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or as directed.
Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 12 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
Ceiling Fan, High Speed, five star energy saving BEE rating, 1200mm sweep, minimum air delivery 210 CFM, AC 230/240 Volts, single phase with squirrel cage induction motor, copper winding including down rod and other accessories etc., hanging the same in position and making connection with three core 23/0.0076 size twisted flexible copper conductor cable upto ceiling rose complete all as specified and directed.
Exhaust fan, metallic body, AC, SP 230/240V, 300mm sweep with louver shutter, 1400 RPM, copper winding, complete with all accessories and fxixng the same in position and making connection with three core 23/0.0076 size twisted flexible copper conductor cable upto ceiling rose complete all as specified and directed.
Air Circulation Fan, AC, SP 230/240V, 750mm sweep, heavy duty, wall mounting, turbo type PSC motor equipped with pre-lubricated ball bearing, motor shall have automatic thermal overload protection, air delivery minimum 300 Cum/Min, steel body, suitable hanger, counting or wall/steel structure all fixing accessories including fixing as per site requirement complete with all electrical wire connections complete all as specified and directed.
Distribution Board iron clad TPN DB, double door with IP-43, IK-09 protection, Four Way, Vertical, suitable MCCB FP 415 Volts 125 Amps rating as incommer and MCB as outgoing complete with appropriate size copper busbar including cutting chases in walls for fixing the DB and making good disturbed surfaces of walls, complete all as specified and as directed. Note : MCBs / MCCBs shall be measured and paid separately under the respective item.
MCCB TPN 415 Volts 125 Amps rating, 25 KA rupturing capacity with adjustable thermal magnetic trip release, complete all as specified and as directed.
MCB SP, 6 to 32 Amps 10 KA, 'C' curve type with rupturing capacity 10 KA complete all as specified and as directed.
MCB SPN, 63 Amps 10 KA, 'C' curve type with rupturing capacity 10 KA complete all as specified and as directed.
MCB TPN, 63 Amps 10 KA, 'C' curve type with rupturing capacity 10 KA complete all as specified and as directed.
Street Light fitting 70 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including fabricated mild steel bracket made of 50 x 50 x 6 mm and clamps of size 40 x 5mm including nuts, bolts and washers complete all as specified and as directed.
Bracket for security light fitting made of 40 mm dia light grade GI pipe, 1.2 metre length bent to suitable shape of fixing of security light fitting with all necessary accessories Bracket, nuts, bolts washers, two clamps made out of flat iron of size 50mm x 5mm x 600mm fabricated in shape and drilled holes for nuts and bolts all as specified and directed
LED Flood Light Fitting of capacity 150 watt with LED bulb having high pressure die cast aluminium housing with sealed toughened glass cover suitable for wall mounting, protection IP66 including making connection with suitable size copper cable three core from DB to fitting all as specified and directed.
LED Flood Light Fitting of capacity 100 watt with LED bulb having high pressure die cast aluminium housing with sealed toughened glass cover suitable for wall mounting, protection IP66 including making connection with suitable size copper cable three core from DB to fitting all as specified and directed.
Integral LED Aviation Light fitting, 10 Watts, IP-65, comprising of die-cast aluminum housing with red polycarbonate dome for better illumination with integral driver, complete all as specified and as directed.
Storage water heater (Geyser), vertical type, of 25 Litre capacity of inner tank, outer tank, syphon assembly, thermostat heating element, safety valve etc complete all as per manufacturer design and specifications including making of all fixing arrangements complete having BEE Five Star Rating including grouting of nuts and bolts and necessary PCC work as specified and directed.
Sub main wiring with four runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with two runs of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Six runs of 6.0 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with two runs of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Four runs of 6.0 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with two runs of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 4.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Four runs of 4.0 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 Sqmm 3.5 core including taking down / up unserviceable cable and making good disturbed surfaces, complete all as specified and directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note : Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub-class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick equal to the length of cable, complete all as specified and as directed.
Galvanized iron water tubing, light grade, 80mm bore for protection of cable with all fittings fixed to walls and ceilings or laid in floors/road crossing, complete all as specified and directed.
Galvanized iron water tubing, light grade, 40mm bore for protection of cable with all fittings fixed to walls and ceilings or laid in floors/road crossing, complete all as specified and directed.
Single pointed Air Termination Aluminium Rod 12 mm dia, 300 mm long to walls / roofs / pipes with suitable clamp of MS with bolts and nuts etc required at site and complete all as specified and directed. Note : Mild Steel work shall be measured and paid separately under the respective item.
Test Point Terminal Block made of gun metal or phosphorus bronze of size 75mm x 75mm x 25 mm with drilled holes and screws including 03 Nos 8mm dia 25 mm long hexagonal head screw of brass with nuts complete duly fitted, grouted on 2 Nos., MS flat 25 x 5mm, fabricated with suitable shape and size and fixing of 02 Nos procelain saddles for mounting of terminal block complete all as specified and directed.
Bracings, supports, clamps, and back plates fabricated from Mild Steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size for holding of pipes , air termination rod, etc and including painting with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Supply, Installation, Testing and Commissioning, Voltage Stabiliser 25KVA capacity for automatic operation servo controlled, copper wound, Three Phase, naturally oil cooled, indoor type and designed for input variation between 340V to 460V suitable for unbalanced voltage in each phase with output voltage stabilized at 415 Volts with accuracy +2.5%, in each phase and speed of corrections 8 Volts per second for unbalanced supply & unbalanced load, complete with first filling of transformer oil having dielectric strength not less than 30 KV as per IS-335, complete with 0-500 Volts and arrangement to check input voltage and output voltage voltmeter, RYB indication lamp high and low, voltage cut off single phase preventor, time delay relay, servo by pass switch, over load and short circuit trip facility complete all as specified and directed.
PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 Sqmm, 3 Core, 1100 Volts grade complete all as specified and as directed.
Supply, installation, testing and commissioning of LT Panel indoor type confirming to IS 8623 Part-I (one), CPRI approval, totally enclosed vermin proof suitably ventilated for Three Phase, 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.0mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP-56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armored cable of adequate size. Computer cut self-adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 70x70x25 cm , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs legs grouted in PCC 1:2:4 and making good disturbed surface complete and comprising of the following :- (A) TPN (i) Aluminum electrolytic grade bus bar of capacity 200 Amps for phases & 150 Amps for neutral. And auxiliary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V, A, KW, KWH), 415V AC alongwith C.T’s of suitable ratio (Set of Three), Class 1.0, complete.
(iii) Indication lamps LED type (RYB) = 01 Set of three. CTs 500/5A class 1.0,15VA(Cast Resin) for metering - 03 Nos. (iv) Internal wiring, with suitable size of FRLS copper conductor cable (B) INCOMER : (i) MCCB 100 Amp FP,16 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 01 No (C) OUTGOING : (i) MCCB 63 Amps FP, 16KA, Ics = 100% Icu with fixed magnetic and adjustable thermal release,adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase separator - 02nos (ii) Phase sequence corrector unit -01 nos (iii) MCB SPN 63 Amp -02 Nos (iv) Changeover switch 100 amp- 01 no complete all as specified and as directed.
Aluminium strip of size 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground / earthing strips all as directed.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically (earth plate not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including earth lead of GI Strip 32 x 6mm size by means of steel bolts, nuts, check nuts and washers test points made of GI strip 40 x 8 mm, 10 cm long, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), in pit, angle iron 25 x 25 x 3 mm frame work with precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) cover reinforced with 8 mm dia TMT bars @ 150 mm C/C both ways and 12 mm dia MS fabricated handle, light grade GI watering pipe 20 mm bore with funnel, wire mesh and light grade GI protection pipe 40 mm bore upto 7.5 m length for drawing in earth lead, salt, charcoal etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete all as shown in electrical plate No. 3 of MES schedule 2009 Part-I Including connecting and testing on completion all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire up to 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
DES RAJ NAGPAL CONTRACTORS PVT.LTD
M/S MOHAN LAL GUPTA
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
R R CONSTRUCTION
M/s V6 Infrastructures Pvt. Ltd.
M/S BHATIA BUILDERS AND CONTRACTORS
SHIVAE CONSTRUCTION
Bidder Name
SHIVAE CONSTRUCTION
M/S MOHAN LAL GUPTA
M/S BHATIA BUILDERS AND CONTRACTORS
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
M/s V6 Infrastructures Pvt. Ltd.
R R CONSTRUCTION
DES RAJ NAGPAL CONTRACTORS PVT.LTD
bamral builder
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .