Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹26.2 L+₹1.7 L (6.96%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹28.0 L+₹3.5 L (14.2%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹29.2 L+₹4.7 L (19.1%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹29.8 L+₹5.3 L (21.7%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Jul 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
EXTERNAL PERIODICAL SERVICES INCLUDING WELCOME MAINT AND MISC E/M WORKS AT ARTRUCH AND CC HUT, GYM ROAD, TRANSIT OFFR ACCN, GREEN MENDOWS, DK-I AND ADJOINING AREA UNDER GE (CENTRAL) DELHI CANTT-10
2023_MES_604635_1
GE/C-35/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
14 Aug 2023
21 Jun 2023
19 Jul 2023
21 Jun 2023
17 Jul 2023
5 Jul 2023
21 Jun 2023 - 5 Jul 2023
Amount
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc all as directed.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc up to 10m height complete all as specified and directed.
M&L for 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to 10m height. complete all as specified and directed by engineer-in-charge complete all as specified and directed complete.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specifed as direted by Engr-in-charge.
M & L for applying two coats of oil bond destember over one coat of birla white wall care putty on newly plastered surfaces(internal) of walls complete all as specified and directed.
M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plaster surface of wall and applying two coats of plastic emulsion paint complete all as specified and all as directed by Engr- in-charge.
M&L for preparation of newly plaster surface of wall and applying two coats of weather proof acralic exterior emulsion paint complete all as specified and all as directed by Engr- in-charge.
M&L for preparation of old decorated plastered surfaces of walls, brooming down,washing with water etc and applying two coats of weather proof acralic exterior emulsion paint up to 10 m height complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by washing, rubbing etc and applying applying two coats of plastic emulsion paint over one coat of putty up to 10 m height complete all as specified and directed.
M&L for old decorated surfaces plastered or unplastered surface of wall and complete removal of existing treatment by washing, rubbing etc and applying two coat of oil bond distemper on wall complete all a spcefied.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing , brooming down,washing with water etc and applying two coat of cement based paint up to 10 m height complete all as specified and directed.
M & L for preparation of Old surface (Plastered or un plastered) on ceiling by completely scraping/ removing the existing treatment and applying two coats of white wash complete.
M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
M & L for preparation of Old or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint.
Servicing and greasing of aluminium door, windows including replacement nut , screws rubber gaskets, pivot, taper clip etc including taking down carefully of door shutter for replacing unserviceable parts/components by new parts /components for smooth functioning of door and refixing the same in existing opening/position, complete, all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed includind taking down and refixing of shutter as in repairs complete all as specified and directed.
S&F in repair aluminium body hydraulically Door closer regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as in repairs complete, all as specified and directed.
S&F in repair for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar all as directed.
S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
Supply and fix figured glass pin head type 4mm thick ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane fixed with oil putty or wooden beads including provision of glazing pins/ spring clips wherever necessary, complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm.
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for conceled water tubing etc cutting exceeding 10cm girth but not exc. 20 cm all as directed.
Supply and fix for vitreous china wash hand basin with PVC board Vanity type of size 550X400mm excluding taps, incl waste pipe & waste fittings with pedestral complete all as specified.
S & F in repair for vitreous china wash hand basin (oven type) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste fittings complete all as specified.
S & F in repair for floor mounted EWC one piece incl all necessary fittings complete all as specified and directed by Engr -in-charge.
S & F in repair for vitreous china wash down water closet pan (padestal pattern) white making good the disturbed surface to match with the existing complete all as specified and all as directed.
S&F in repair for Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws all as specified and as directed.
Supply only in repair Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devic.
S & F in repair for PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified all as specified.
S & F in repair for 15 mm dia 600mm long PVC connections with brass check nut complete .
S & F in repair for Glass Corner Shelf 6mm thick including CP railing radius 250mm complerte all as specified and directed by Engineer-in-Charge.
S & F in repair for Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railing complerte all as specified and directed by Engineer-in-Charge.
S & F in repair for Health faucet, CP brass with 1.50m long flexible pipe complerte all as specified and directed by Engineer-in-Charge.
S & F in repair for bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S & F in repair 15mm dia Pillar taps, brass CP, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed .
S&F in repair for angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
S&F in repair for 15 mm bore gate valve,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S&F in repair for 20 mm bore gate valve,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F in repair for Chromium plated brass overhead shower with arm complete all as specified and directed.
S&F in repairs chromium plated brass central hole WHB mixer 15 mm bore chromium plated, fancy type including joints to hot and cold complete all as specified.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thick in vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
Dismentling asbestos cement corrugated or semi corrugated sheets in roof fixed with L hook or cranked bolt.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old sheets all as specified.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L PCC 1 : 4 : 8, type D2, using 40mm graded stone aggregates, as in foundation of manholes etc complete all as specified.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S & F in repair kitchen plate rack with four shelves made out of stainless steel sheet 1mm thick over all size 75cm X75cm X 20cms complete all as specified & directed.
S & F for sink with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and waist including bedding in cement mortar to dwarfwall or including fixing cantilever, brackets and connecting union to pipe overall size 915x460mm, bowl size 410x330x160mm complete all as specifed as direted.
S&F for brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO)of as all specifed and as directed. Code SOL-6281
M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished een and smooth without using extra cement up to hieght of four storey ,including scaffolding complete.
M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished even and smooth without using extra cement in multistorey building,complete all as directed.
M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajja in multy storey building etc complete all as specified.
Supply only integral water proofing admixture of approved quality.
M&L for preparation of old decoreated external wall / internal wall/Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying 2 mm thick wall care putty over a coat of cement primer up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 3 storey bldg complete all as specified and all as directed by Engr- in-charge. Note: 1. Stage for preparation of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+4 bldg including scaffolding. 3. Hard copy of MoU with manufacurer/ authorised labour will be submitted before opening of Technical Bid. In absance of the same bid will be rejected.
M&L for Preparation of old painted surfaces of wood surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
Taking down care fully copper/aluminium point wiring from wooden batten (except) conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 73 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/Exh fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 75 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 4 Module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge .
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20/22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F High efficient LED Street light fitting not less than 35 W with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge.
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and fix in repair MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Schedule of Credit
a.k constructions
LAMBA ENTERPRISES
imran construction company
Pall Associates
M/s SAAR ENGINEERS
M/S MSD & Associate
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .