Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52,400Admitted-Fee/PreQual/Technical/Finance | ₹52,400 | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹59,575+₹7,175 (13.7%)Admitted-Fee/PreQual/Technical/Finance | ₹59,575+₹7,175 (13.7%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹74,740+₹22,340 (42.6%)Admitted-Fee/PreQual/Technical/Finance | ₹74,740+₹22,340 (42.6%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹75,009+₹22,609 (43.1%)Admitted-Fee/PreQual/Technical/Finance | ₹75,009+₹22,609 (43.1%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹78,193+₹25,793 (49.2%)Admitted-Fee/PreQual/Technical/Finance | ₹78,193+₹25,793 (49.2%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Rayees Electric Engineering Works L6 | M/S WASEEM TRADERS L5 | M/S BHAT ENTERPRISES L1 | M/S RELIANCE ELECTRICALS L2 | S T ELECTRICAL ENG WORKS PEERNAR LALGAM TRAL L3 | M/S MIR ELECTRICALS and MECHANICAL ENG WORKS L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing, fitting, testing and Commissioning of new 3 Pole, 50HZ, 400AMP, MCCB with thermal magnetic release with a breaking capacity of 50 KA at 415V AC after removing the damaged one by suitable means. The job includes removing of the old damaged MCCB from the main control panel board by way of isolating the incoming lines and disconnecting all the incoming/outgoing connections. The job shall include cutting of the damaged portions of outgoing cables and then providing and fitting of required no. Of new Al. thimbles of required size reconnecting with incoming and outgoing connections and testing the MCCB`s on full load. | 1 | job | 33,125 ₹33,125 | 27,515 ₹27,515 | 21,000 ₹21,000 Lowest | 35,000 ₹35,000 | 32,990 ₹32,990 | 31,410 ₹31,410 |
| 2.00 | Providing and fitting of 250 Amp,3-pole 415V MCCB with thermal magnetic release having 50 kA breaking capacity (Ics= 100% Icu) (Make: L&T/Schneider or equivalent).The job includes removing of old damaged Mccb`s from main panel and fitting of new mccb`s with new thimbles as per sample and testing of the same on full load. | 1 | job | 24,157 ₹24,157 | 22,331 ₹22,331 | 31,000 ₹31,000 | 24,000 ₹24,000 | 21,750 ₹21,750 | 20,999 ₹20,999 Lowest |
| 3.00 | Providing and fitting of 185 sq.mm PVC insulated 1100V single core industrial Aluminium cable (40mtrs) for incoming supply to Motors as the existing cable is completely damaged.The job comprises of providing and fixing of Aluminium terminals(30 No) of Dowels/Reputed make of suitable size and Amperage,P/F of suitable galvanised Nuts and bolts of required Number and size The crimping of terminals by using hydraulic crimping tool. | 1 | job | 21,780 ₹21,780 | 28,347 ₹28,347 | 400 ₹400 Lowest | 575 ₹575 | 20,000 ₹20,000 | 22,600 ₹22,600 |
Tender Value
₹85,000
EMD Value
₹1,700
Closing Date
5 Jun 2026, 11:00 amClosed
Executive Engineer MID Anantnag hq Awantipora
MIDA
Cost on account of various electrical works at LIS Patikawni.
2026_IFC_310530_12
Enit 10 of 2026-27
Open Tender
Electrical Works
Turn-key
15 days
patikawni
Please refer Tender documents.
2 documents required · 2 mandatory
₹50
executive engineer MID Anantnag
₹1,700
18 Jun 2026
21 May 2026
6 Jun 2026
21 May 2026
5 Jun 2026
21 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, fitting, testing and Commissioning of new 3 Pole, 50HZ, 400AMP, MCCB with thermal magnetic release with a breaking capacity of 50 KA at 415V AC after removing the damaged one by suitable means. The job includes removing of the old damaged MCCB from the main control panel board by way of isolating the incoming lines and disconnecting all the incoming/outgoing connections. The job shall include cutting of the damaged portions of outgoing cables and then providing and fitting of required no. Of new Al. thimbles of required size reconnecting with incoming and outgoing connections and testing the MCCB`s on full load. | - | job | - | - |
| 2 | Providing and fitting of 250 Amp,3-pole 415V MCCB with thermal magnetic release having 50 kA breaking capacity (Ics= 100% Icu) (Make: L&T/Schneider or equivalent).The job includes removing of old damaged Mccb`s from main panel and fitting of new mccb`s with new thimbles as per sample and testing of the same on full load. | - | job | - | - |
| 3 | Providing and fitting of 185 sq.mm PVC insulated 1100V single core industrial Aluminium cable (40mtrs) for incoming supply to Motors as the existing cable is completely damaged.The job comprises of providing and fixing of Aluminium terminals(30 No) of Dowels/Reputed make of suitable size and Amperage,P/F of suitable galvanised Nuts and bolts of required Number and size The crimping of terminals by using hydraulic crimping tool. | - | job | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.26 MB
BOQ_1004508.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .