Tender Value
₹24.9 L
EMD Value
₹49,900
Closing Date
15 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRAWING
12 conditions · 1 needing a document upload
The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650 V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to650 V. Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected. Note: In case of expiry of validity of license during contract, the contractor should renew the license so that it is always valid during contract
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
9 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer /s are required to submit a scanned / attested copy of following information along with their tender- 1. Bank Account No 2. Name of Bank 3. Indian Financial System Code {IFSC} 4.PAN No 5. Tenderers Contact No Contractor should provide firms PAN, issued by Income Tax Department with his quote or within30 {Thirty} days of award of contract. No payment will be released without submission of PAN. All taxes including surcharge and cess shall be recovered from his payment as per tax provisions in vogue.
The tenderer shall thoroughly go through the entire tender document and strictly adhere the instructions and directions given at different pages.
It is responsibility of the tenderer that they ensure to see any corrigendum of the tender to check the corrigendum on the website from time to time.
All the required/supporting documents should be scanned and uploaded.
In case the date of closing mentioned in the Notice Inviting Tender is declared a holiday/bandh/strike etc. on any account, the date of closing tender online will not be changed as the application in the website of IREPS does not permit submission of any offer after closing date and time of the tender. However, opening of tenders online will be on any convenient day after the closing date/time of tenders.
Opening of e-tender online:- The e-tenders will be opened online using the IREPS portal. No representative is required to be present for opening of tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders in the website after the opening of the tender.
Nanded Division: Renovation of Existing 140T Crane Shed for TRD Tower Wagon Shed at Nanded- Electrical Arrangements
NED-E-26-2026-27~SCR
NED-E-26-2026-27
Open
Works - General
12 Months
Nanded, Maharashtra
₹0
₹49,900
22 Sept 2026
22 Sept 2026
1 Oct 2026
136 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 24,93,187 | ||
| — | 20.00 | — | — | ||
| Supply of 16W 3directional LED Pit Light fitting with IP67 Protection(10W+4W+2W) aluminium diecast with IP67 Protection as per specification. Note Prior Approval to be taken including all accessories. | — | — | — | 44,080 | |
| — | 20.00 | — | — | ||
| Erection of 16W 3directional LED Pit Lightfitting with IP67Protection(10W+4W+2W) aluminium diecast with IP67 Protection as per specification. Note Prior Approval to be taken including all accessories. | — | — | — | 2,400 | |
| — | 2.00 | — | — | ||
| Design, supply of SMPS control Panel unit containing 3 nos of 24V10A SMPS power supply units enclosed in sheet steel enclosure with all necessary accesorries. Note Prior Approval to be taken including all accessories. | — | — | — | 32,272 | |
| — | 2.00 | — | — | ||
| Erection of SMPS control Panel unit containing 3nos of 24V 10A SMPSpower supply unitsenclosed in sheet steelenclosure with allnecessary accesorries. .Note Prier Approval to betaken including allaccessories. | — | — | — | 678 | |
| — | 6.00 | — | — | ||
| Supply of 60W LED Flood light fixture complete with necessary mounting accessories, clamps and hardware etc. | — | — | — | 18,612 | |
| — | 6.00 | — | — | ||
| Erection, connecting, testing and commissioning of 60W LED Flood light fixture complete with necessary mounting accessories, clamps and hardware etc | — | — | — | 678 | |
| — | 100.00 | — | — | ||
| Supply of CPVC pipeSDR-13.5 class -I pipe of size 20 mm (3/4 inch). | — | — | — | 12,600 | |
| — | 100.00 | — | — | ||
| Erection of CPVC pipeSDR-13.5 class -I pipe ofsize 20 mm (3/4 inch). | — | — | — | 300 | |
| — | 20.00 | — | — | ||
| Supply of CPVC 20 mm dia (3/4 inch) Tee including fixing etc | — | — | — | 660 | |
| — | 20.00 | — | — | ||
| Erection of CPVC 20 mm dia (3/4 inch) Tee including fixing etc | — | — | — | 40 | |
| — | 20.00 | — | — | ||
| Supply of metal clampwith suitable screws(length type) on concretesurface includingprovision of plugs with allaccessories for CPVC 20mm dia (3/4 inch). | — | — | — | 240 | |
| — | 20.00 | — | — | ||
| Fixing of metal clamp with suitable screws (length type) on concrete surface including provision of plugs with all accessories for CPVC 20mm dia (3/4 inch). | — | — | — | 20 | |
| — | 320.00 | — | — | ||
| Cutting and chipping thewall for laying the PVC conduit pipe and plastering after laying thePVC conduit pipe withcement and sand mortarmixed with 1:8 ratio, butwithout laying PVCconduit pipe. | — | — | — | 16,000 | |
| — | 30.00 | — | — | ||
| Provision of concealed wiring with two runs of 1.5 Sq.mm 1100 Volts and one run of flexible copper conductor 1.5Sq.mm 1100 Volts FRLS PVC insulated wires ISI marked (Phase, neutral and earth)( upto 10 meters lenght) inthe PVC conduit pipe with 6A flush modular type switch including 2 way switches where ever required, ceilingrose, bulb holder and modular type plate cover to MS switch control box including all labour charges complete forlight points, ceiling fans and exhaust fans points cat walk points and ioh service buidling points etc. accessories. | — | — | — | 19,920 | |
| — | 160.00 | — | — | ||
| Supply and run of 2 nos, 2.5 sqmm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of1.5 sqmm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit Pipe conforming to IS694 (2010) with latest amendements. | — | — | — | 16,160 | |
| — | 60.00 | — | — | ||
| Supply and run of 2 nos, 6.0 sqmm, 1100 V PVC (FRLS) insulated flexible copper conductor wires and one run of2.5 sqmm PVC (FRLS) insulated flexible copper cable for earthing in existing PVC conduit Pipe conforming to IS694 (2010) with latest amendements. | — | — | — | 10,740 | |
| — | 220.00 | — | — | ||
| Supply and Running of 25 mm dia, Ivory coloured PVC conduit ( ISI marked) of wall thickness not less than 2mm along with junction boxes, bends and all accessories etc. as required as per site requirement. Running ofconduit, fixing with suitable clamps and nuts in groove / open /shelter | — | — | — | 10,560 | |
| — | 6.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 6A 3pin/5pin modular plug socket, with 6A modular controlswitch on existing control board with wiring. | — | — | — | 2,082 | |
| — | 4.00 | — | — | ||
| Supply and fixing of metal flush box-12 module of model no:JIM 12 008 of GM FOURFIVE make or its equivalentwith 12 module cover plate (With support frame) of model no:PK SB 12 007 - CASABLANCA of GM make orequivalent make comply with IEC 60669-1 with its latest amendments including all accessories complete. | — | — | — | 1,648 | |
| — | 4.00 | — | — | ||
| Supply and fixing of metal flush box-4 module of model no:JIM 04 003 of GM FOURFIVE make or its equivalentwith 4 module cover plate (With support frame) of model no:PK SB 04 004 - CASABLANCA of GM make orequivalent make comply with IEC 60669-1 with its latest amendments including all accessories complete. | — | — | — | 880 | |
| — | 4.00 | — | — | ||
| Supply and fixing of 10A SP 1 Modular mini MCB conforming to IS:13947, C" Curve Model No.AB 1 111 of GMmake or it's equivalent in Module box including all accessories complete. | — | — | — | 1,384 | |
| — | 16.00 | — | — | ||
| Supply and fixing of 20W 4 feet LED tube light with all connected accessories complete for fixing (The supplyincludes accessories such as clamps, ties extension wires etc for fixing) as per attached railway specification | — | — | — | 6,160 | |
| — | 4.00 | — | — | ||
| Supply and Erection of B curve 16A DP MCBs of Rated Short-Circuit Breaking Capacity 10kA of IP 20 Protection asper IS/IEC 60898 - 1 with its latest amendments with all connected accessories. | — | — | — | 2,620 | |
| — | 4.00 | — | — | ||
| Supply, fixing and connecting of 2pole 2 module 32A Lexic RCBOs conforming to IS 12640-2(2008) with its latestamendments as advised by the site supervisor with all necessary accessories complete. | — | — | — | 13,824 | |
| — | 1.00 | — | — | ||
| Supply of DPX3 160+18 of 8 way DB of legrand cat no.5077 47 with metal door with provision for incomer ofMCCB up to 160 Amps , bus bar of capacity 250A and outgoing for 18 Module with busbar din and neutral linkwith all necessary accessories complete or equivalent make. | — | — | — | 16,212 | |
| — | 2.00 | — | — | ||
| Supply and fixing and connecting P-17 Tempra plug and socket IK 08, of 16A, 2P+E - DP of model no.5078 60 oflegrand make or equivalent as per IS/IEC 60309-1 (2002) with its latest amendments. | — | — | — | 7,500 | |
| — | 2.00 | — | — | ||
| Supply and fixing and connecting P-17 Tempra plug and socket IK 08, of 63A, 3P+N+E -FP of model no.507864of legrand make or equivalent as per IS/IEC 60309-1 (2002) with its latest amendments. | — | — | — | 28,150 | |
| — | 2.00 | — | — | ||
| Supply and fixing of C curve DP MCBs of 16/20/32 A with all connected accessories. | — | — | — | 1,724 | |
| — | 3.00 | — | — | ||
| Supply and fixing of DP MCB enclosures model no.5077 91 of legrand make or its equivalent. | — | — | — | 2,139 | |
| — | 2.00 | — | — | ||
| Supply and fixing of FP MCB enclosures model no.5077 93 of legrand make or its equivalent. | — | — | — | 1,822 | |
| — | 3.00 | — | — | ||
| Supply and fixing of 63 A 4P MCB C Curve, 10 KA capacity with necessary connections and all accessories complete. | — | — | — | 8,223 | |
| — | 4.00 | — | — | ||
| Supply, fixing and connecting of Cable Junction Boxes IP 55/IP 65 with metric knockouts for cable entry Cablejunction boxes of model no. K 9504 of Hensel make conforming to IS:13573/92,IEC 60947-3 with its latestamendments, with necessary terminals suitable for cables upto 50 Sq mm and all necessary accessoriescomplete. | — | — | — | 29,244 | |
| — | 4.00 | — | — | ||
| Supply, Erection and connecting of Cable Junction Boxes IP 55 / IP 65 with metric knockouts for cable entry Cablejunction boxes of model no. K 1204 of Hensel make or equivalent make with necessary terminals suitable forcables up to 150Sq mm and all necessary accessories complete. | — | — | — | 95,324 | |
| — | 100.00 | — | — | ||
| Supply, Laying, Testing and Termination of LTUG 4 core 25 sqmm XLPE insulated PVC sheathed Aluminiumarmoured cable as per IS 7098 (Part 1) 1988 with latest amendments and with necessary lugs and terminationscomplete. | — | — | — | 20,300 | |
| — | 100.00 | — | — | ||
| Supply, Laying, Testing and Termination of 1.1 KV Grade 4 core 50 sqmm XLPE insulated PVC sheathedAluminium armoured cable as per IS 7098(Part 1)1988 with latest amendments and with necessary lugs andterminations complete. | — | — | — | 34,100 | |
| — | 1000.00 | — | — | ||
| Supply, Laying, Testing and Termination of 4 core 120 sqmm XLPE insulated underground armoured aluminiumcable with heat resistant insulation as per IS 7098(Part 1)1988 with latest amendments with necessary lugs andterminations complete. | — | — | — | 8,48,000 | |
| — | 60.00 | — | — | ||
| Excavation of cable trench under the Track below 2mtrs. horizontal drilling bore with Hydrallic Jack suitable sizefor provision of 110/50mm dia GI/HDPE pipe. | — | — | — | 1,27,860 | |
| — | 60.00 | — | — | ||
| Supply and Installation of 300mm x 50mm x 2mm thick GI perforated cable tray with cover along with requiredangle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall/ Ceiling etc. complete. | — | — | — | 39,120 | |
| — | 20.00 | — | — | ||
| Supply and Laying of 4 core 10 sqmm copper cables XLPE insulated, cores laid up, PVC innersheathed unarmoured 650/1100V grade as per IS 7098(Part 1) 1988. | — | — | — | 9,320 | |
| — | 1000.00 | — | — | ||
| Supply and laying of HDPE pipe of PE-80grade in PN-4 outer dia of HDPE pipe110mm (nearest 4"" dia) and wallthickness minimum 4.1 mm maximum 4.3mm with ""T' joints, bends, elbows etc.including all other connected accessories.Make: M/s.Sudhakar/ Nagarjunapolymer/Nandi/Plasto | — | — | — | 3,12,000 | |
| — | 200.00 | — | — | ||
| Supply, erecting and laying of HDPE pipeof PE-80 grade in PN-4 outer dia of HDPEpipe 63 mm (nearest 2" dia) and wallthickness minimum 2.5 mm maximum 2.8mm with "T' joints, bends, elbows etc.including all other connected accessories.Make: M/s.Sudhakar/ Nagarjunapolymer/Nandi/Plasto | — | — | — | 24,800 | |
| — | 80.00 | — | — | ||
| Supply of 100 mm dia 'B' class ERW GIpipe conforming to IS: 1239 Part 1(2004)and fixing with suitable clamps onwall/building including laying of cablethrough GI pipe. | — | — | — | 85,920 | |
| — | 300.00 | — | — | ||
| "Cutting of esphated road/ concrete/ cement/under the track etc., and excavation of cable trench 30cm widex90cm deep oad etc., for laying of HT/LTUG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and asper directions of Rly.Engineer." | — | — | — | 60,900 | |
| — | 300.00 | — | — | ||
| Excavation of cable trench 30 cm wide x 90cm deep in all types of soils for HT/LTUG cable as per specification | — | — | — | 36,600 | |
| — | 1300.00 | — | — | ||
| Supply and running of 8 SWG GI wire is tobe laid for earth continuity. | — | — | — | 15,600 | |
| — | 6.00 | — | — | ||
| Supply and erection of earth electrode as perthe enclosed specification (including digging earth pit, electrode earth box with reinforced concrete complete with all connected materials and works including connecting the earth electrode and aerial earthing according to IS 3043 and RDSO drawing ETI/OHE/P/7021 in other than substations. | — | — | — | 22,788 | |
| — | 4.00 | — | — | ||
| Supply and fixing of Ventilating Fans(Exhaust fan) of 4 pole 300 mm sweepsize with metallic body with capacitorconforming to IS No.2312/67 (Reaffirmed2005) complete with louver and allconnected accessories. Make:Havells/CG/Bajaj/Khaitan | — | — | — | 9,120 | |
| — | 400.00 | — | — | ||
| Providing and fixing sheetmetal work in CRCA sheetwith fabrication of boxespanel boards etc. includingcutting, bending, drilling,welding, riveting etc.treated with anti-rusttreatment and duly powercoated as per the abovespecification. | — | — | — | 99,600 | |
| — | 80.00 | — | — | ||
| Supplying and erecting of50 mm x 5 mm sizeelectrolyte copper patti orbar in bus bar chamber / inpanel or any other purpose,500 V with require capacitywith 99.9% copper puritywith fixing arrangement(like lug or bottle type lug)to both the end with highgrade polyolefin insulationsleeve complete | — | — | — | 90,400 | |
| — | 2.00 | — | — | ||
| Supplying and erecting LTCT multifunction DLMScompliance energy meter of accuracy of class 0.5with optical & RS 232 port,backlit LCD, measures &displays tri vector energy,load survey, TOD, tamperdetection & logging, powerON /OFF events,instantaneous parametersof rating 1/5 A with displayin absence of powercomplete with zeroadjustment & testcertificate frommanufacturer erected onprovided M.S. box andconnected to CTs suitablefor 3x240V,50 Hz. | — | — | — | 16,274 | |
| — | 12.00 | — | — | ||
| Supplying and erecting LTcurrent transformer withbar primary 50/5 to 1000/5ratio with 15 VA burdenerected in provided CRCAbox duly secured withinsulating materialsconnected to the meterwith test certificates. | — | — | — | 10,536 | |
| — | 4.00 | — | — | ||
| Supplying and erectingpanel mounting type digitalammeter having three andhalf digit LED display,external CT operated,calibrated for 0 to 1000AAC supply with necessaryPVC wire leads and lugsand mounting hardware onprovided panel completewith calibration certificatefrom manufacturer suitableto operate on 500V. | — | — | — | 5,444 | |
| — | 4.00 | — | — | ||
| Supplying and erectingpanel mounting type digitalvoltmeter having Three andhalf digit LED display,calibrated for 0-750V ACsuitable to operate on 500VAC supply with necessaryPVC wire leads and lugsand mounting hardware onprovided panel completewith calibration certificatefrom manufacturer suitableto operate on 500V. | — | — | — | 5,220 | |
| — | 8.00 | — | — | ||
| Supplying and erectingselector switch suitable forvoltmeter/ammeter for 3phase AC supply500/1000V, 50Hz, onprovided box / panel andduly connecting withnecessary PVC wire leadsand lugs. | — | — | — | 2,560 | |
| — | 4.00 | — | — | ||
| Supply & provision of 3 NosRYB indication lamps ofLED type including with allconnected accessoriescomplete. | — | — | — | 1,752 | |
| — | 3.00 | — | — | ||
| Supply, erection, testingand commissioning of allmaterial, excavation, andcasting of cement concretefoundation/concreting inratio 1:3:6 | — | — | — | 18,021 | |
| — | 4.00 | — | — | ||
| Supply, fixing and connecting of 750 mm (30") sweep wall mounting air circulator with all connected accessories. Make :Crompton/Havells/Bajaj/ Usha only. | — | — | — | 32,056 | |
| — | 2.00 | — | — | ||
| Supply & fixing testing andcommissioning of 200A on-load change over switchsuitable to operate on415V, 50Hzconforms toIS:13947-3 with sheetsteel enclosure fronthandle operated. Make:L&T/Legrand/Havells orSimilar | — | — | — | 44,530 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing andcommissioning ofMicroprocessor Release200-250 A ; 4Pole, MCCBsuitable for operation on415V,50 Hz 3 Phase ACsupply in LT Panel withsupply of all connectedaccessories and alliedmaterials as perspecification attached.Make: L&T/Legrand/Havells Or Similar | — | — | — | 67,638 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of Microprocessor Release125 A ; 4Pole, MCCB suitable for operation on415V,50 Hz 3 Phase AC supply in LT Panel withsupply of all connectedaccessories and alliedmaterials as perspecification attached.Make: L&T/Legrand/Havells Or Similar | — | — | — | 14,197 | |
| — | 1.00 | — | — | ||
| Supply and installation of DPX3 160 thermal magnetic based release ; Icu = 36K A; 100A 4 Pole MCCB conformto IEC 60947-2 of model no. 4200 95 of Legrand make or equivalent make with extended ROM , spreader links (2sets). | — | — | — | 9,139 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 40 A Electromechanical 4P RCBO 30 mA sensitivity as per in accordance with IS12640-2 & IEC 61009-1, of Model No.DHBMACTN8030040 of Havell's Make or its equivalent withnecessary connections and all accessories complete | — | — | — | 9,546 | |
| — | 2.00 | — | — | ||
| Supply and fixing of 32 A 4P MCB B Curve IS/IEC 60898-1 (2002) 10 kA breaking capacity IP20protected terminals of model no.402463 of Legrand make or it's equivalent. | — | — | — | 4,442 | |
| — | 2.00 | — | — | ||
| Supply ,Erection,Commissioning of63A/100A 100mAsensitivityas per thedirection oftheengineer at site. | — | — | — | 7,448 | |
| — | — | — | 6 | ||
| — | 20.00 | — | — | ||
| Supply of Bimetallic (aluminum and copper ) Cable Lugs for 25 sqmm size cables | — | — | — | 580 | |
| — | 20.00 | — | — | ||
| Supply of Bimetallic (aluminum and copper ) Cable Lugs for 70 sqmm size cables | — | — | — | 1,120 | |
| — | 20.00 | — | — | ||
| Supply of Bimetallic (aluminum and copper ) Cable Lugs for 120 sqmm size cables | — | — | — | 1,360 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
GCCCorrectionSlips1to12_compressed.pdf GCC Correction slips
ATTACHMENT
Earthing
ATTACHMENT
RitesInspectionLetter.pdf
ATTACHMENT
TenderBookletNEDE26202627.pdf
ATTACHMENT
GCCCorrectionSlips1to12_compressed.pdf
ATTACHMENT
TechCircular05-2022Earthingcompressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .