Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹6.5 L
Closing Date
14 Sept 2026, 4:00 pm4d left
Bengaluru Water Supply And Sewerage Board
Nalini
LAYING OF MS PIPELINE AND DI PIPELINE ALONG WITH ITS OTHER UTILITIES
BWSSB/2026-27/WS/WORK_INDENT3340/CALL-2
BWSSB/2026-27/WS/WORK_INDENT3340/CALL-2
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
BWSSB Head Office Bengaluru
4 documents required · 4 mandatory
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
The Tenderer as prime contractor should have satisfactorily completed during the last five years at least one similar work to an extent of 50% of the cost of the work value not less than Rs. 216.13 lakhs (Water supply pipeline work forming DMA network only). Executed in any one year, the following minimum quantities of work , Providing, laying, testing and Commissioning of MS pipeline completed in all respects of 400 mm dia and above for 345 Rmt AND 700 mm dia and above for 345 Rmt , Providing, laying, testing and Commissioning of 100mm dia DI pipe completed in all respect for 100 mm dia and above for 1240 Rmt, Supply, laying, jointing, Testing and commissioning of service connections making bore holes for fix house service connections including road cutting, excavation, backfilling, disposal and road restoration for 120 Nos. The contractor, as a prime contractor should have carried out the above works in DMA concept. Also, the contractor should have carried out the trenchless work, in complete manner of having installed the casing and carrier pipes for 1600mm and above dia of MS casing pipes of 12 mm thick for 20 m.
Liquid assets and /or availability of credit facilities of no less than Rs.129.68 Lakhs (estimated cash flow for 3 months of peak construction period)
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract Rs.864.54 LAKHS
List of existing commitments and ongoing works
₹5,000
₹6.5 L
4 Sept 2026
2 Sept 2026
15 Sept 2026
10 Sept 2026
10 Sept 2026
Work of Providing supply and laying 700 mm & 400 mm dia MS pipeline in place of leaky 700 mm & 400 mm dia CI feeder line from Bharath Petrol Bunk in cantonment road to AKS conventional hall under AEE(UFW) sub-division
Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Means Bituminous course For Asphalt surface/ paveme...
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantle...
Earth work excavation for pipeline trenches in all kinds of soils by mechanicalmeans as per drawing and technical specifications, including setting out,construction of shoring, strutting, barricading,...
Earth work Depth exceeding 1.5 m, but not exceeding 3 m
Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bra...
Earthwork excavation Depth exceeding 1.5 m, but not exceeding 3 m
Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barri...
Earthwork excavation(hard rock) Depth exceeding 1.5 m, but not exceeding 3 m
Excavation of Hard rock by Diamond rope cutting method using diamond rope, line draw machine, making holes by drilling machine for breaking the block by means of hydrolic breakers/splitters without an...
Refilling available earth around trenches/pipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 ...
Carting of excavated earth of all types upto a distance mentioned below and re-carting back the eath to the same site by vehicle including loading, unloading charges for to & fro, with all lifts, labo...
Spreading of stone dust: Supplying and providing stone dust in the station yard or whereever required including watering, ramming, conslidiating and dressing. the rates includes the cost of the materi...
Removal of Unservicable soil with disposal upto a suitable distance as directed by the Engineer incharge of the work
Dewatering the sewage / storm water by using reqired HP submersible
pump for the diversion of storm / sewage during the execution of work.
Considering for one Pump-5 hp pump
D.I.Pipe : Providing and laying Ductile Iron pipes of class conforming to IS8329:2000 with latest amendments, conveying to work site, rolling and lowering into trenches, laying true to line, level and...
Providing and fixing of DI specials with ISI mark confoming to IS 9523 / 2000 suitable for jointing 100 mm to 600 mm dia DI pipes coated with rust prevention coatings as below: NOTE: A) External coati...
Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft...
Manufacturing, providing, trasporting, rolling, lowering, layin,jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conform...
406 mm dia x 6.4 mm thick MS Pipes
Manufacturing, providing, transporting, rolling, lowering. Laying and jointing, testing and commissioning of MS specials of min 6mm and 8 mm thick conforming to IS 7322.1985 with latest ammendments, p...
Up to and inclusive of 500 mm dia of pipe of 6mm thick, (with inside and out side lining two coats of food grade apoxy painting of approved make 250 micron thick (after dry) for bends, branches, MSMJ ...
Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire ch...
400 mm dia x 20 mm thick
Excavating of ramming/jacking/driving pit and receiving pit of size 5.00m(length) x 3.00m (breadth), up to 6.00 m depth in all soil strata including shoring and strutting including cutting of Asphalt/...
Installation of product pipe by manual jacking method - Manufacturing, providing, transporting, rolling, lowering, laying & jointing, testing, commissioning of ERW (Electric Resistance Welded), SAW (S...
Providing and fixing kinetic AIR VALVE of PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 o...
Supply, laying, jointing, Testing and commissioning of service connections making bore holes for fix house service connections including road cutting, excavation, backfilling, disposal and road resto...
Supply, laying, jointing, of additional length (exceeding 3.0m) of CPVC service pipe
15 mm / 20mm connection in road / footpath / verge
Trial holes are excavations carried out with the approval of the Engineer to investigate pipe network details, connectivity, etc. Rate to include road cutting, excavation, backfilling, disposal and ro...
Dismantling size stone masonry in clay mortar and stacking the size stone with in a radius of 50 m and removing the debries to a distance upto 200 m cost of labour charges complete and as directed by...
Reconstruction of stone masonry with cement mortar 1:6 with the available stones including cost of labour, curing etc., complete
Removing and refixing of B.S. Slabs/RCC Slabs of drain and refixing after completion of the work with all tools and tackles
Providing and laying in position Ready Mixed or Batch Mixed concrete as perIS 10262 mix design procedure for Cement Concrete works in all types ofStructures other than Road works, using coarse aggrega...
Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggre...
Road restoration - GSB - 200MM
KSRRB M400-Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mi...
KSRRB M500-6: Prime Coat over WMM/WBM Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at ...
KSRRB M500-13:Providing and laying Bituminous Macadam with 120 tph capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-40 @ 3.3% by weigh...
Providing and applying tack coat with RS1 Bituminous Emulsionusing emulsion pressure distributor at the rate of 0.25 kg/m2 on Granular Surface.
Providing and laying Bituminous Concrete with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.2 per cent of mix and f...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
DTP- BPB TO AKS CONVENTION 2nd call.doc
Tender Document • 1.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .