Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAdmitted-Finance 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | ₹6.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.4 Cr+₹54.0 L (7.89%)Admitted-Finance | ₹7.4 Cr+₹54.0 L (7.89%) | L2 | Admitted-Finance |
| 3 | L3₹14.9 Cr+₹8.1 Cr (117.8%)Admitted-Finance PLOT NO 43B E BLOCK INDUSTRIAL DEVELOPMENT AREA AUTONAGAR GAJUWAKA VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹14.9 Cr+₹8.1 Cr (117.8%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical 34 SANJAY BUILDING NO 6 ANDHERI KURLA ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | - | - | Rejected-Technical Non compliance with tender terms and conditions (Payment terms) |
| Sl No | Description | Qty | Unit | JAMI HYDRAULICS PVT LTD L3 | Fiumetech Mechanics Private Limited L2 | SMEC AUTOMATION PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 2.00BEING A SPECIALISED GEO-TECHNICAL VESSEL & THE DRILL EQUIPMENTS ARE OLD & COMPLEX, ALL HYDRAULIC JOBS TO BE CARRIED ONLY BY HIGHLY SPECIALISED WORKSHOPS WHO HAVE CARRIED OUT SUCH JOBS ON BOARD IN THE DRY DOCK IN THE PAST AFTER OBTAINING APPROVAL FROM ONGC/SUPERINTENDENT/GEOTECHNICAL BASE MANAGER. FLUSHING OF THE HYDRAULIC SYSTEM TO BE CARRIED OUT BY ONLY HIGHLY SPECIALISED TEAMS WHO HAVE CARRIED OUT SUCH JOBS ON BOARD IN THE DRY DOCK IN THE PAST AFTER OBTAINING APPROVAL FROM ONGC/SUPERINTENDENT/GEOTECHNICAL BASE MANAGER. ALL HYDRAULIC PIPELINES TO BE PICKLED/FLUSHED TO ACCEPTABLE STANDARDS PRIOR USE. | ||||||
| 3.00G26001 POWER SWIVEL (Type 3-5/1.1-2.3-6.6/Ha): (Top Drive) | ||||||
| 4.00 | G26001.1
The power swivel unit approx. weight is 3 tons. Workshop has to arrange all necessary handling tools, shore crane and skilled manpower to remove power swivel from vessel. Arrange necessary transport for both side transport of unit. After servicing the unit has to be fitted back to the place. Acceptance is subject to successfuk sea trials. Required tools - like wire slings length approx. 4mtr. capacity 5tons, D- Shackles, hydraulic jack, Gas cutter and chain blocks 5ton capacity to be provided by Vendor. | 1 | LS | 58,55,500 ₹58,55,500 | 7,50,500 ₹7,50,500 Lowest | 8,65,000 ₹8,65,000 |
| 5.00 | G26001.2
Arrange MHWirth Service Engineer/suitable workshop to dismantle and overhaul power swivel complete unit, worn out part to be renewed.
Max. Admissible oil for driving the power swivel = 420 LPM
Max pressure – 250 bars. With l.h. speed.
Max pressure – 200 bars. With r.h. speed.
Dynamic load carrying capacity of power swivel = 40 Mp
Static carrying capacity of power swivel = 60 Mp, 2 nos. Of hydraulic motor A2F 80
Thrust bearing = SKF 51156 (dyn. 319 KN & Stat. 1460 KN), Self weight – 3 Tons.
Power Swivel Chuck: I.D. – 210 mm, Max. Clamping dia. 205 mm, Incorporated clamping jaws for dia. 177.8 mm, Clamping rang dia. 174 – 180 mm. Max Static load carrying capacity 40 MP.
Following equipment of power swivel to be overhauled in inclusion. Note: Currently sea water and gear oil were mixed up in power swivel 1) Power swivel rotary full unit- main sleeve inner ring (up and down) and seal (up and down) all bearings, all O rings, all gear wheels, pinion gears etc.
2) Power swivel planetary gear box - 2 nos.
3) Hydraulic Motors type A2F 80 -2nos.
4) Power swivel insert complete ( Wash pipe assy to be renewed). 5) Power swivel gear shifting mechanism -2 nos.
6) All the connecting hoses and end fittings of power swivel system to be renewed.
7) Lub oil pump Pipe lines to be renewed.
8) Chuck Cylinder fitment ring to be renewed and aligned properly - 2nos. 9) Dismantle and clean power insert, slush pipe, cross over sub,clamping jaw fixture and end ring. Replace worn out parts and bearings. 10) Axial roller bearing to be removed from the gear box. Dismantle and remove gear from the casing. If any damage or scoring mark found, surface area to prepared.
11) Assemble complete unit with proper greasing and packing gaskets.
12) Power swivel & cover / casings to be cleaned & coated with anti corrosive paint.
Following spare are to be procured and renewed. | 1 | LS | 76,85,000 ₹76,85,000 | 63,95,074 ₹63,95,074 Lowest | 80,55,000 ₹80,55,000 |
| 6.00 | G26001.3
a) Axial cylindrical roller bearings 81164 -320x400x63 - 2nos. | 2 | Nos | 11,55,000 ₹23,10,000 | 6,80,960 ₹13,61,920 | 3,25,000 ₹6,50,000 Lowest |
| 7.00 | G26001.4
b) Cylindrical roller bearings NJ 2312 - 2NOS. | 2 | Nos | 12,65,700 ₹25,31,400 | 33,025 ₹66,050 Lowest | 90,000 ₹1,80,000 |
| 8.00 | G26001.5
c) Needle bearings 300x380x80,NA 4860 - 1no. | 1 | No | 8,55,000 ₹8,55,000 | 2,97,493 ₹2,97,493 | 2,50,000 ₹2,50,000 Lowest |
| 9.00 | G26001.6
d) Needle bearings 300x380x80,NA 4864 - 1no. | 1 | No | 5,86,000 ₹5,86,000 | 3,83,040 ₹3,83,040 | 2,30,000 ₹2,30,000 Lowest |
| 10.00 | G26001.7
e) Grooved ball bearing 6010, DIN 625 - 1no | 1 | No | 1,35,000 ₹1,35,000 | 1,916 ₹1,916 Lowest | 5,900 ₹5,900 |
| 11.00 | G26001.8
f) Axial grooved ball bearing 51156, Messrs. SKF - 2nos. | 2 | Nos | 5,78,000 ₹11,56,000 | 1,78,091 ₹3,56,182 Lowest | 1,95,000 ₹3,90,000 |
Tender Value
Refer Docs
Closing Date
20 Jun 2026, 2:00 pmClosed
DGM(SRM)
SRM, Cochin shipyard,Kochi
GEO TECH TENDER 1 FOR THE VESSEL SAMUDRA SARVEKSHAK AT CMSRU
2026_CSL_280340_1
CSL/MP2/1939
Open Tender
Marine Works
Turn-key
30 days
CMSRU
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
1 Jul 2026
9 Jun 2026
22 Jun 2026
9 Jun 2026
20 Jun 2026
9 Jun 2026
9 Jun 2026 - 17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | BEING A SPECIALISED GEO-TECHNICAL VESSEL & THE DRILL EQUIPMENTS ARE OLD & COMPLEX, ALL HYDRAULIC JOBS TO BE CARRIED ONLY BY HIGHLY SPECIALISED WORKSHOPS WHO HAVE CARRIED OUT SUCH JOBS ON BOARD IN THE DRY DOCK IN THE PAST AFTER OBTAINING APPROVAL FROM ONGC/SUPERINTENDENT/GEOTECHNICAL BASE MANAGER. FLUSHING OF THE HYDRAULIC SYSTEM TO BE CARRIED OUT BY ONLY HIGHLY SPECIALISED TEAMS WHO HAVE CARRIED OUT SUCH JOBS ON BOARD IN THE DRY DOCK IN THE PAST AFTER OBTAINING APPROVAL FROM ONGC/SUPERINTENDENT/GEOTECHNICAL BASE MANAGER. ALL HYDRAULIC PIPELINES TO BE PICKLED/FLUSHED TO ACCEPTABLE STANDARDS PRIOR USE. | - | - | - | - |
| 3 | G26001
POWER SWIVEL (Type 3-5/1.1-2.3-6.6/Ha): (Top Drive) | - | - | - | - |
| 4 | G26001.1
The power swivel unit approx. weight is 3 tons. Workshop has to arrange all necessary handling tools, shore crane and skilled manpower to remove power swivel from vessel. Arrange necessary transport for both side transport of unit. After servicing the unit has to be fitted back to the place. Acceptance is subject to successfuk sea trials. Required tools - like wire slings length approx. 4mtr. capacity 5tons, D- Shackles, hydraulic jack, Gas cutter and chain blocks 5ton capacity to be provided by Vendor. | 1 | LS | - | - |
| 5 | G26001.2
Arrange MHWirth Service Engineer/suitable workshop to dismantle and overhaul power swivel complete unit, worn out part to be renewed.
Max. Admissible oil for driving the power swivel = 420 LPM
Max pressure – 250 bars. With l.h. speed.
Max pressure – 200 bars. With r.h. speed.
Dynamic load carrying capacity of power swivel = 40 Mp
Static carrying capacity of power swivel = 60 Mp, 2 nos. Of hydraulic motor A2F 80
Thrust bearing = SKF 51156 (dyn. 319 KN & Stat. 1460 KN), Self weight – 3 Tons.
Power Swivel Chuck: I.D. – 210 mm, Max. Clamping dia. 205 mm, Incorporated clamping jaws for dia. 177.8 mm, Clamping rang dia. 174 – 180 mm. Max Static load carrying capacity 40 MP.
Following equipment of power swivel to be overhauled in inclusion. Note: Currently sea water and gear oil were mixed up in power swivel 1) Power swivel rotary full unit- main sleeve inner ring (up and down) and seal (up and down) all bearings, all O rings, all gear wheels, pinion gears etc.
2) Power swivel planetary gear box - 2 nos.
3) Hydraulic Motors type A2F 80 -2nos.
4) Power swivel insert complete ( Wash pipe assy to be renewed). 5) Power swivel gear shifting mechanism -2 nos.
6) All the connecting hoses and end fittings of power swivel system to be renewed.
7) Lub oil pump Pipe lines to be renewed.
8) Chuck Cylinder fitment ring to be renewed and aligned properly - 2nos. 9) Dismantle and clean power insert, slush pipe, cross over sub,clamping jaw fixture and end ring. Replace worn out parts and bearings. 10) Axial roller bearing to be removed from the gear box. Dismantle and remove gear from the casing. If any damage or scoring mark found, surface area to prepared.
11) Assemble complete unit with proper greasing and packing gaskets.
12) Power swivel & cover / casings to be cleaned & coated with anti corrosive paint.
Following spare are to be procured and renewed. | 1 | LS | - | - |
| 6 | G26001.3
a) Axial cylindrical roller bearings 81164 -320x400x63 - 2nos. | 2 | Nos | - | - |
| 7 | G26001.4
b) Cylindrical roller bearings NJ 2312 - 2NOS. | 2 | Nos | - | - |
| 8 | G26001.5
c) Needle bearings 300x380x80,NA 4860 - 1no. | 1 | No | - | - |
| 9 | G26001.6
d) Needle bearings 300x380x80,NA 4864 - 1no. | 1 | No | - | - |
| 10 | G26001.7
e) Grooved ball bearing 6010, DIN 625 - 1no | 1 | No | - | - |
| 11 | G26001.8
f) Axial grooved ball bearing 51156, Messrs. SKF - 2nos. | 2 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
TD.pdf
Tender Documents • 1.52 MB
BOQ_327163.xls
BOQ • 0.42 MB
DateCorrigendum.pdf
PDF • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .