| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹19.1 L+₹8.6 L (82.2%)Rejected-Finance 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Rejected, as stood L2 | |
| 3 | L3₹21.8 L+₹11.3 L (107.7%)Rejected-Finance 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | L3 | Rejected-Finance Rejected, as stood L3 |
Tender Value
₹10.5 L
EMD Value
₹20,978
Closing Date
3 Mar 2025, 12:00 pmClosed
EE_II, Kol. South Health El. Divn.,P.W.Dte.
75 D H Road Kidderpore Kol_23
Repair, reinstallation, testing and commissioning of the Fire Detection and Alarm system of different buildings of M.R. Bangur DH, South 24 Pgs.
2025_WBPWD_815190_1
WBPWDEE-IIKSHEDQ93/24-253rdCal
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,978
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
9 Apr 2025
12 Feb 2025
5 Mar 2025
12 Feb 2025
3 Mar 2025
20 Feb 2025
19 Feb 2025
Amount
Testing and Recommissioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) installed in various buildings with in the hospital premises as per direction of the E.I.C .
Repair, Installation, reprogramming and commissioning of UL listed and FM approved two loop analog addressable Fire Alarm system having the total panel capacity of 252 devices,. The recommissioned fire panel shall be compatible with the existing multi sensor detectors installed at present. The repairing has to be done by a agency having UL certification/ license. The work has to be done as per direction of E.I.C. Make : Siemens - UL.
Testing and Recommissioning of of Networked Active Repeater Panel in various buildings with in the hospital premises.
Through Checking and cleaning of the existing devices as well as properly connecting the same with ones own tools and tackles and with all necy items as required as mentioned below -
Analog Addressable Intelligent multisensor detector IP 40/Heat Detectors ( VDS / UL make) with base
Addressable Manual Call Point ( VDS / UL make)
Addressable Loop Powered Hooter cum strobe
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector IP 54 ( VDS / UL /EN54/ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Honeywell/Cerberus Pro/ Siemens )
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/ Gloster/Polycab) through 20 mm dia PVC 'FR' type Rigid Conduit pipe including S & laying of the 20 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision) on the surface of the wall.
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db. ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL/EN54/ERTL/ FM approved). (Approved Make: Honeywell/Cerberus Pro/ Siemens ) Note : Hooter must be Addressable by itself or by using control module. If Loop Power Hooter is not used, separate wiring from control Panel up to the the hooter will be in contractor scope without any extra cost.
Supply, Installation, Testing & Commissioning of Addressable Manual Call Point ( VDS/UL/EN54 approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Siemens-Cerberus Pro)
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/EN54 approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make: Esser/Cerberus Pro/Siemens)
Supply, Installation, Testing & Commissioning of 12V, 7.5 Ah SMF (Lead -Acid) Battery for fire panel. (Make: Exide/Amaron) with all other accessories.
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
TERMS & CONDITIONS :-
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
PERFECT IMAGE SOLUTIONS (BID ID -6168054)
Creative Projects (BID ID -6188122)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .