Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95,000Accepted-AOC PARMANDAL MORH RATNUCHAK JAMMU | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹1.0 L+₹6,750 (7.11%)Rejected-AOC 111 MINI SHOPPING COMPLEX NEAR HOTEL ASIA NEHRU MARKET JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | L2 | Rejected-AOC NOT THE LOWEST BIDDER | |
| 3 | L3₹1.0 L+₹8,000 (8.42%)Rejected-AOC 235 YARD 6 NARWAL JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | L3 | Rejected-AOC NOT THE LOWEST BIDDER | |
| 4 | L4₹1.0 L+₹9,500 (10.0%)Rejected-AOC | L4 | Rejected-AOC NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Vaibhav Engineers and Technocrates L3 | KUMAR ELECTRICAL DEVICE L1 | AADISHWAR ELECTRICAL AND MECHANICAL WORKS L2 | MUSKAN ELECTRICAL L4 |
|---|---|---|---|---|---|---|---|
| 1.01 | Reconditioning of 02 Nos 6.6 kV HT (VCB) panels (HT Motor feeder spare VCB panel NO.7 and LT transformer panel having current rating 800 amp and system voltage 6.6 KV) installed at TPH Jammu by way of providing and fitting of new Components such as shunt trip coil , Closing Coil , spring charging Motor, Anti pumping relay with base , Breaker Auxiliary Switch , Aux Contactor 110 V DC in place of damaged/ worn out above noted Components. The job further involves Complete fitting of all the new parts of HT panel .Job involves visual inspection of all the components .complete servicing of panel by way of cleaning all the terminal with CRC spray and tightening the terminals properly, applying lubricant to all mechanical linkages for smooth operation, cleaning and smoothening of finger contacts points by rubbing gently with 0 grade emery cloth checking all control wiring and replacing any wire seems worn out/ electrical stressed by P/F new wire and maintaining proper color code and using ferrule for proper identification, Resetting /adjustment of vacuum interrupter for proper gap between fixed and moving contacts, checking IR value between phase-phase and phase and phase and earth. , checking contact resistance of poles of breaker . Checking working of charging and release mechanism. Checking mechanical interlocks such as Racking, service, test position ,earth switch, shutters. Inserting vacuum circuit breaker in the compartment and again testing closing and tripping of breaker.
B. Reconditioning/repair and servicing of transformer panel (VCB panel) having Current rating 800 AMP., System Voltage 6.6 KV, installed at Tawi Pump House Jammu by way of providing and fitting of new Components such as shunt trip coil, Closing Coil, TNC switch, Aux Contactor 110 V AC, 04 NO+04 NC in place of damaged/ worn out above noted Components. The job involves Complete fitting of all the new parts of HT panel and cleaning all the terminal with CRC spray , tightening all the terminals properly, applying lubricant to all mechanical linkages for smooth operation, cleaning and smoothening of finger contacts points by rubbing gently with 0 grade emery cloth checking all control wiring and replacing any wire seems worn out/ electrical stressed by P/F new wire and maintaining proper color code and using ferrule for proper identification, checking working of all the components. Resetting /adjustment of vacuum interrupter for proper gap between fixed and moving contacts and checking working of charging and release mechanism. Checking contact resistance of each pole and insulation resistance of Phase-phase and phase earth. Checking mechanical interlocks such as Racking, service, test position ,earth switch, shutters Inserting vacuum circuit breaker in the compartment and again testing closing and tripping of breaker. Complete job includes cost of material and labour charges, including transportation of material upto site (TPH). | 1 | Job | 1,03,000 ₹1,03,000 | 95,000 ₹95,000 Lowest | 1,01,750 ₹1,01,750 | 1,04,500 ₹1,04,500 |
Tender Value
Refer Docs
EMD Value
₹2,100
Closing Date
17 Sept 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Mech Div. RTIC Jammu
Office of Executive Engineer Mech Div. RTIC Jammu
Reconditioning of 2 no. 6.6 KV HT (VCB) panels installed at Tawi Pump House, Jammu.
2026_IFC_324008_1
E-NIT NO 18 OF 2026-27 DT. 09-09-2026
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Office of Executive Engineer Mech Div. RTIC Jammu
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
Yes
Executive Engineer Mech Div. RTIC Jammu
₹2,100
Yes
Office of Executive Engineer Mech Div. RTIC Jammu
30 Oct 2026
9 Sept 2026
18 Sept 2026
9 Sept 2026
17 Sept 2026
11 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Reconditioning of 02 Nos 6.6 kV HT (VCB) panels (HT Motor feeder spare VCB panel NO.7 and LT transformer panel having current rating 800 amp and system voltage 6.6 KV) installed at TPH Jammu by way of providing and fitting of new Components such as shunt trip coil , Closing Coil , spring charging Motor, Anti pumping relay with base , Breaker Auxiliary Switch , Aux Contactor 110 V DC in place of damaged/ worn out above noted Components. The job further involves Complete fitting of all the new parts of HT panel .Job involves visual inspection of all the components .complete servicing of panel by way of cleaning all the terminal with CRC spray and tightening the terminals properly, applying lubricant to all mechanical linkages for smooth operation, cleaning and smoothening of finger contacts points by rubbing gently with 0 grade emery cloth checking all control wiring and replacing any wire seems worn out/ electrical stressed by P/F new wire and maintaining proper color code and using ferrule for proper identification, Resetting /adjustment of vacuum interrupter for proper gap between fixed and moving contacts, checking IR value between phase-phase and phase and phase and earth. , checking contact resistance of poles of breaker . Checking working of charging and release mechanism. Checking mechanical interlocks such as Racking, service, test position ,earth switch, shutters. Inserting vacuum circuit breaker in the compartment and again testing closing and tripping of breaker.
B. Reconditioning/repair and servicing of transformer panel (VCB panel) having Current rating 800 AMP., System Voltage 6.6 KV, installed at Tawi Pump House Jammu by way of providing and fitting of new Components such as shunt trip coil, Closing Coil, TNC switch, Aux Contactor 110 V AC, 04 NO+04 NC in place of damaged/ worn out above noted Components. The job involves Complete fitting of all the new parts of HT panel and cleaning all the terminal with CRC spray , tightening all the terminals properly, applying lubricant to all mechanical linkages for smooth operation, cleaning and smoothening of finger contacts points by rubbing gently with 0 grade emery cloth checking all control wiring and replacing any wire seems worn out/ electrical stressed by P/F new wire and maintaining proper color code and using ferrule for proper identification, checking working of all the components. Resetting /adjustment of vacuum interrupter for proper gap between fixed and moving contacts and checking working of charging and release mechanism. Checking contact resistance of each pole and insulation resistance of Phase-phase and phase earth. Checking mechanical interlocks such as Racking, service, test position ,earth switch, shutters Inserting vacuum circuit breaker in the compartment and again testing closing and tripping of breaker. Complete job includes cost of material and labour charges, including transportation of material upto site (TPH). | 1 | Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
2.pdf
Tender Documents • 0.39 MB
BOQ_1092229.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .