| 1 | 1₹15.8 LAccepted-AOC | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹17.0 L+₹1.2 L (7.48%)Rejected-Finance 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | 2 | Rejected-Finance Not L1 Bidder | |
| 3 | 3₹17.5 L+₹1.7 L (10.8%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | 3 | Rejected-Finance Not L1 Bidder | |
| 4 | 4₹17.9 L+₹2.1 L (13.0%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | 4 | Rejected-Finance Not L1 Bidder | |
| 5 | 5₹21.8 L+₹6.0 L (37.7%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | 5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹14.7 L
EMD Value
₹29,320
Closing Date
16 Dec 2021, 6:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
AUGMENTATION OF POWER TRANSFORMER BY INSTALLATION OF HIGHER CAPACITY TRANSFORMER IN REPLACEMENT OF EXISTING TRANSFORMER AT RTC ER KOLKATA UNDER GE N KOLKATA
2021_MES_489132_1
8124/21-22/E8/GE(N)/KOL OF 2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
RTC SALTLAKE
As per NIT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹29,320
Yes
20 Jan 2022
18 Nov 2021
17 Dec 2021
19 Nov 2021
16 Dec 2021
2 Dec 2021
Amount
Supply, installation, testing and commissioning outdoor type platform mounted step down transformer(EEL 2 Type) of capacity 400 KVA, 11 KV/415 Volts (at NO load), AC 3 Phase, 50 HZ, core type double copper wound, oil immersed, naturally cooled, oil natural-Air natural (ON/AN) with external cooling tubes, delta connection on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with Neutral brought out on secondary side (LV side) and having tapings at (+/-) 2.5% and (+/-) 5%, (+/-)7.5%, (+/-)10% on HV side to be changed by means of hand operated OFF load tap changer gear and transformer should conforming to level-2 of IS-1180/ 2014. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree celsius. Transformer shall comprise of the following , read in conjuction of PS Clauses as applicable :- Note : All material and equipment required on testing by SEI / Electrical inspector shall be provided by the contractor (a) One cable box LT side (secondary side) consisting of four Nos porcelain bushing with copper rods complete with nut & washers with one No cable gland suitable for reception/ taking out of 240 Sqmm 3 1/2 core LT 1100 Volts grade XLPE insulated and PVC sheathed heavy duty armoured cable including gland, joint & jointing material complete all as specified. (b) HT side (primary side) consisting of three Nos porcelain bushing with copper rods complete with nut and washers with cable gland HT busing suitable for outdoor mounting transformer, 11000 Volts grade XLPE insulated heavy duty armoured cables including gland joint and jointing material complete. (c) Oil conservator with filter type drain valve and oil level guage complete. (d) De-hydrating breather with first fill of dehydrating agent (silica gel) complete. (e) One 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (f) Four earthing terminals on tank cover to facilitate fixing of 32mm x 6mm galvanised iron earth strip for earthing of neutral & body. (g) Rating plate and terminal marking plate. (h) Extra bushing for neutral in the LT cable box for providing independent set of earthig for neutral. (j) First filling of new and unused transformer oil IS-335 marked filtered and tested upto 60 KV dielectric strength at 2.5mm air gap between testing electrodes. Note :All material and equipment required for testing by SEI/ Rep of CWE will be provided by the contractor. The completion certificated will be issued after carrying out all required test satisfactorily after installation , testing and commissioning of the transformer, as directed by the SEI, / Rep of CWE, appointed by CWE, at site. The transformer shall be got tested in the presence of GE or representative of CWE, as appointed at factory workshop prior to delivery at site. The equipment shall bear the IS testing mark. The test certificates shall be submitted to the GE duly defaced by the Engineer- In - Charge. Make:- ABB/SIEMENS/VOLTAMP/CROMPTON GRERAVES/ ALSTOM/ SCHNEIDER/ BHARAT BIJLEE/INDIAN TRANSFORMER/ESENNAR TRANSFORMER/KOTSONS PVT.LTD / M/S JAYBEE INDUSTRIES.
Supply, installing, testing and commissioning of air break, gang operated tripal pole switch with DO, out door horizontal/ vertical type (ISI marked) mechanically operated, mounting on insulators and frame work (steel work for mounting GOD etc) with operating mechanism worked from ground level with locking arrengement including Godrej pattern 65mm pad lock with two keys complete suitable for HT 11 KV, 50 Hz AC supply including necessary connection complete all as specified and directed by Engr-in-Charge of 200 Amp rating with 12 Nos insulator complete with DO and HT fuse element. Make:- jaipuria & sons / Bhel / L&T / Seimens
Supply and errection steel tubular pole swaged type 11.0 meter long, type 410 SP-55, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washer etc. painting of poles with one coat of red oxide primer and two coat of aluminum paint before fixing and one coat of aluminum paint after fixing on exposed surface and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & red colour starting with red colour (each band of 30 cm wide ) by two coat of synthetic enemeled paint up to 1.5m height including complete all as specified and directed by Engr-in-charge. Make :Calcutta Poles & Tubes / Jindal Steel Poles / National Tubing Co./ Bansal Poles./ Subham poles.
S&F cross arms, bracing, support, clamps etc. made out of mild steel channel or angle section of required size and shape including clamps, back plate with bolts, nuts & washers drilling for insulator bolts sha welding, bending cold or hot in any shape or size including all fixing arrangement on HT over head line and painted with two coats of alumiunum paint over a coat of red oxide zinc chrome primer complete all as specifed & directed. Make:- Rinl / Sail / Tisco/JAI Balaji industries ltd / Shyam Steel industries Ltd. / SPS stell rolling mills ltd / SRMB Srijan Pvt Ltd / Electrosteel steels ltd / Shyammetallics and energy ltd / Jindal.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation of pole, stay etc, including use and waste of formwork,complete.
M&L for Danger notice plate of 1.6mm thick mild steel sheet,vitreous enamelled white,with letters,figures and conventional skull and bones in signal red colour and fixed with M.S.clamps,bolts and nuts of size 25X20 cm for HT supply.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 185 sq mm. Make: M/s Havells / M/s Nicco / M/s KEI / M/s Polycab / Gloster / Universal) / HPL/ Dynamic cables / Finolex. / RR kabel / Mescab
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sq mm to 185sq mm. complete all as specified and directed
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 sq mm to 185sq mm. Make for item nos. 8 & 9:- BIRLA-3M / Rachem / Denson.
Supply and fixing Pipes galvanized, “Light Grade/ class”, supplied And laid complete including fittings100 mm (4”) dia complete all as specified and directed. Make:-Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal /Nezone/ M/S BST Infratech Ltd.
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead strip 32x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead strip protected by and including 40 mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 150mm C/C both way and two Nos lifting handle made of 8mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete and as specified in electrical plate No 3 of SSR Pt I including taking down old earthing complete all as specified as directed. Note:- Strip up to 7 mtr inculded in the above quoted rate.
Excavation in trenches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables, foundation of poles, stay etc complete all as specified.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M & L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for payment.
supplying and laying un-reinforced precast concrete cable cover , class HV, Type 1, flat, size 300mmx180mmx40mm. Note:- Test certificate is mandatory brfore claiming payment.
Supply and fixing lightening arreastor Non-linear resistor type, Gapless metal oxide(ZnO) suitable for 3 wire 11KV overhead line with rated voltage of 9KV(rms), 5Ka discharge current with a station class with facility to record numbers of surge and complete with galvanised clamping arrangements clamps, bolts, nuts, washers etc. as required . Make:- L&T/ Indo Asian / C&S / Havells / HPL / Legrand / ABB / bajaj
M & L for anticlimbing device i.e. Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia completed all as specified and directed
Supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA completed all as specified and directed Make:Standard / L&T/ Indo Asian / C&S / Havells / HPL / Legrand / ABB
PODDAR SALES CORPORATION
ELECTRO COMMERCIAL CO
RADHA ENTERPRISE
INDIA ELECTRICAL EQUIPMENTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .