Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹8,500
Closing Date
13 Mar 2020, 3:05 pmClosed
EXECUTIVE ENGINEER (SDW) IX
EXECUTIVE ENGINEER (SDW) IX RITHALA STP SEC-11 ROHINI DELHI-110085
Renovation of lighting system of the EE(SDW)IX and SE(SDW)II offices along with their toilets, adjoining room and corridor at STP Ph-I Rithala.
2020_DJB_189180_6
N .I. T. No. 12 EE (SDW) IX (2019-20)
Open Tender
Miscellaneous Works
Item Rate
30 days
EXECUTIVE ENGINEER (SDW) IX
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
EMD A/c No. 50448339804 at Allahabad Bank,
₹8,500
23 Apr 2020
4 Mar 2020
13 Mar 2020
4 Mar 2020
13 Mar 2020
4 Mar 2020
Dismantling of all old wiring, electrical illumination fittings, fans, MCB’s, MS/GI boxes, plates, switches, conduits etc. as per site requirement and shifting it to a safer place.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit ,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR 2018, 1.10.2
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.DSR 2018,1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and15/16 A modular switch, connections etc. as required. DSR 2018,1.32
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. i) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR 2018, 1.14.2
ii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 2018, 1.14.3
iii) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire DSR 2018, 1.14.5
6) Supply of Batton integrated LED channel 18 W/ 20 W fitting Make: Havells/Philips/ Bajaj/ Crompton /any other approved make of DJB.
7 Supply of 2’ X 2’ LED panel 34 W/36 W recess mounting with high brightness LED’s with low glare complete in all respect for proper illumination. Make: Havells/ Philips/ Bajaj/ Crompton /any other approved make of DJB.
8 Supply of wall fan size 400 mm sweep, Make: Crompton/ Havells/ Usha/ Orient/Bajaj/ Khaitan
9 Supply of MCB DP 40 A Make: L&T/Havells/C&S
10 Supply of MCB sheet steel enclosure 2 way. Make: L&T/Havells/C&S
11 Supply of 1.5 Ton 5 Star rating Air conditioner Window type. Make: Voltas/Blue Star/ Loyyd/ Carrier/ Hitachi/Panasonic/Mitshubishi
12 ITC for pre-wired fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. Directly on ceiling / wall including connection with 1.5 mm FR PVC insulated, copper conductor, single core cable and earthing etc. as reqd. DSR 2018, 1.41
13 Installation of wall fan on the wall at suitable height with the help of fasteners i/c connection, testing, commissioning etc. as required
14 ITC of 40 A MCB DP in the MCB sheet steel enclosure on the wall as required including connections etc.
15 ITC of air conditioners in the window by making required changes in the existing window with all connections etc. as required.
16) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door DSR 2018, 2.5.1.
17) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. DSR 2018, 2.10.1
18) Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 A DSR 2018, 2.13.3
HARI ELECTRICAL CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .