Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.7 L+₹7.9 L (28.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.0 L+₹10.2 L (36.9%)Rejected-Finance | L3 | Rejected-Finance other than lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to work load in hand more than 5 times of tendering limit being one class below tenderer |
| Sl No | Description | Qty | Unit | shyam construction L1 | M/S S S CONSTRUCTION L3 | ASHOK INFRATECH L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation of poles, laying of cables etc. and getting out in soft/loose soil complete all as specified and directed | 920 | Cum | 100 ₹92,000 | 160 ₹1,47,200 | 50 ₹46,000 Lowest |
| 2.00 | Excavation in soft /loose soil in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr in depth and getting out complete all as specified and directed | 0.86 | Cum | 150 ₹129 | 160 ₹137.6 | 50 ₹43 Lowest |
| 3.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and directed | 549 | Cum | 30 ₹16,470 | 60 ₹32,940 | 20 ₹10,980 Lowest |
| 4.00 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed | 371 | Cum | 30 ₹11,130 | 60 ₹22,260 | 10 ₹3,710 Lowest |
| 5.00 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable and punned the sand for protection of cable complete all as specified and directed
Note:- For payment punned thickness shall be measured and paid. | 276 | Cum | 500 ₹1,38,000 | 750 ₹2,07,000 | 250 ₹69,000 Lowest |
| 6.00 | Supply and laying reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150mm x 40mm complete all as specified and directed | 22,717 | Each | 10 ₹2,27,170 | 15 ₹3,40,755 | 9 ₹2,04,453 Lowest |
| 7.00Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area including taking down old unserviceable cable:- Note:- Excavation, returning and removal shall be paid and measured seperately under respective item of BOQ | ||||||
| 7.01 | 10 Sqmm 4.0 core. | 800 | RM | 120 ₹96,000 Lowest | 130 ₹1,04,000 | 150 ₹1,20,000 |
| 7.02 | 16 Sqmm 4.0 core. | 600 | RM | 140 ₹84,000 Lowest | 170 ₹1,02,000 | 250 ₹1,50,000 |
| 7.03 | 25 Sqmm 3.5 core. | 500 | RM | 200 ₹1,00,000 Lowest | 200 ₹1,00,000 Lowest | 275 ₹1,37,500 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
5 Jun 2026, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender document
2026_MES_765680_1
8144
Open Tender
Civil Works
Item Rate
270 days
GE (East) Mathura
As per NIT Document
6 documents required · 6 mandatory
₹500
GE (East) Mathura
₹1 L
Yes
16 Jul 2026
15 May 2026
12 Jun 2026
15 May 2026
5 Jun 2026
29 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation of poles, laying of cables etc. and getting out in soft/loose soil complete all as specified and directed | 920 | Cum | - | - |
| 2 | Excavation in soft /loose soil in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr in depth and getting out complete all as specified and directed | 0.86 | Cum | - | - |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified and directed | 549 | Cum | - | - |
| 4 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed | 371 | Cum | - | - |
| 5 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable and punned the sand for protection of cable complete all as specified and directed
Note:- For payment punned thickness shall be measured and paid. | 276 | Cum | - | - |
| 6 | Supply and laying reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150mm x 40mm complete all as specified and directed | 22,717 | Each | - | - |
| 7Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape / wire armoured heavy duty electric underground cable, 1100 volts grade with stranded aluminium conductor of following nominal cross sectional area including taking down old unserviceable cable:- Note:- Excavation, returning and removal shall be paid and measured seperately under respective item of BOQ | |||||
| 7.01 | 10 Sqmm 4.0 core. | 800 | RM | - | - |
| 7.02 | 16 Sqmm 4.0 core. | 600 | RM | - | - |
| 7.03 | 25 Sqmm 3.5 core. | 500 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tenderk.pdf
Tender Documents • 1.36 MB
BOQ_857541.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .