SUPERINTENDING ENGINEER
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
Work sanctioned under Additional Business Plan 2024-25
2024_PVVNV_963142_1
12/EUDC(G)/2024-25
Open Tender
Electrical Works
Lump-sum
30 days
Area of EUDD-IV GKP
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
SUPERINTENDING ENGINEER EUDC
₹1.9 L
11 Nov 2024
5 Oct 2024
21 Oct 2024
5 Oct 2024
19 Oct 2024
5 Oct 2024
Amount
fo|qr uxjh; forj.k [k.M&prqFkZ xksj[kiqj ds vUrxZr fctusl Iyku esa Lohd`r u;s 250 ds0oh0,0 forj.k ifjorZdksa dh LFkkiuk ds dk;ksZ dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
250 KVA Transformer
11 KV XLPE Cable 3X120 sq mm
11 KV C/J Kit 3X120 sq mm
ST Pole 09 mtr long
ST Pole 11 mtr long
MS Top Channel (125x65x2240) mm
MS angle (Dropper) 100X50X2028 mm
ACSR Weasel conductor
ACSR Dog conductor
11 KV Pin Insulator with pin
11 KV Disc insulaor with fiitings
LT AB Cable (3X150+1X120+1X16) sq mm
LT Cable 1X35 sq mm
11 KV Fuse set
11 KV V cross arm
11 KV T-Off Channel
Stay complete (Stay rod 16X1800 mm, stay wire 5 kg, stay clamp, bolt & nuts)
Earthing complete
LT Cable 1X240 sq mm
Supply of following material/fitting complete in all respect :-
LT Three Phase Distribution box
Clamp for LT Three Phase DB Box
Suspension Clamp with I hook (Insulated)
Dead end Clamp with I hook (Insulated)
Piercing Connector (Insulated)
F Bracket
Holding Clamp for top, dropper channel Fuse set etc with nuts & bolts
Copper Z Calmp
Nuts & bolts of different sizes
Al Lugs
The excavation of 2 No foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of PCC Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp/PCC/LT clamp, F-Bracket, LT shacle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). All work will be done as per RESPO norms & relevent IS Specification.
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Fabrication, errection, commissioning & Testing of 250 KVA T/F on Plinth with all accessories including make its LT and HT connection. All neessary materials will be supplied by the Contractor.
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification (Materials will be provided by contractor)
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Laying of ACSR Dog/Weasel conductor for LT/HT Line with fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size as per required.
Making Loop alongwith dressing, Marking, Tagging and Hoisting of cable on Single/Double pole using G.I. Pipe 6"dia 3 mtr. Long with complete work.
Erection of 11 KV 3X120 Sq.mm. Cable Jointing Kit
Erection of 11 KV Fuse set
Construction of T/F plinth of size 2x2x1.2 M with the help of first class brick & 9" masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely and plastering outer surface as per RESPO norms. Top of the plinth covered with 4" RCC Slab of ratio 1:1.5:3 (Cement, sand & concrete) grouting with 2 No ISMC size 125X65X6 MM (confirming to IS 808:1989) of 2000 mm long for resting. All required materials will be provided by the contractor.
Grill fencing of 11/0.4 KV S/S shall be made of rectangular of size & height approx 2 meter as per site requirement with fabrication 50X50X5 mm angel the frame is also have 1 No Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESPO specification.
Laying & sagging of ABC (3X150+1X120+1X16) Sq.mm. Cable of LT Line with fixing of Distribution Box with Clamp, Insulated Dead end clamp with I hook, Suspension clamp with I hook(Insulated), LT insulated Piercing connector, XLPE 1X35 Sq.mm. Al. cable for enerzing DB, XLPE 1X16 Sq.mm. Al. cable for giving connection to Street Light and nuts&bolts off size by the contractor.
Supply and Complete Installation of 2 Nos. Henley Type Tailless Unit 300 AMP in Box using LT XLPE 1X240 Sq.mm. Cable, LT Crimping Lug, GI Nuts & Bolts etc (as per site requirement) on 11/0.4 KV Distribution Transformer. (Only LT XLPE 1X240 Sq.mm. Cable will be provided by Department) Specification of Henley Type Tailless Unit 300 AMP described as below- 1. Henley Type MS Sheet duly painted grey enameled paint- MS of 18 SWG (54X4.5 inches) with holes as per requirement 2. 6 No. Insulator- Made of White Glazed Porcelain 3. 6 No. Copper Spring Contact- 32X3.7 mm Made of Copper 4. 3 No. "L" Contact - Brass 5. 3 No. Metal Part Connector For Holding Busbar- Brass 6. 1 No. Casted Patti- M.S. 7. 1 No. Neutral- Brass 8. Iron Clip, Bolt, Nuts, Washer and Screw etc for Tightening- All Galvanized 9. Copper Bus Bar Strip- 500X50X5 mm (3 Nos.Copper Busbar Strip to be used on 2 Nos. Tailless unit) 10. Aluminium Bus Bar Strip- 500X50X5 mm (1 No) All work will be done as per RESSPO Norms & relevent IS Specification.
Supply, fabrication, erection of LT Pillar Box for Tailless Unit after making Plinth of Height 300 mm above ground level LT Pillar Box Size- 1650X1050X520 mm with Gate and Proper Locking arrangement (Canopy of 15 Degree ) All work will be done as per RESSPO Norms & relevent IS Specification.
fo|qr uxjh; forj.k [k.M&prqFkZ] xksj[kiqj ds {ks= esa fctusl Iyku esa Lohd`r vkj0,e0;w0 yxkus ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
3x185 mm2 XLPE 11 kV
Cable jointing kit 11 kV XLPE 3X185 sq mm
11 kV, 630, 21 kA Ring Main Unit, 3 Way
Laying and dressing of under ground 11 KV 3X185 sq mm XLPE Cable by Horizontal drilling method as per RESPO norms. The Depth of horizontal drilling shall be between 2 to 3 meters or as per site required.
Errection of 11 KV 3X185 sq mm XLPE Cable Jointing Kit with complete work
Erection of 11 kV Ring Main Unit
Plinth for 11 kV Ring Main Unit
Earthing (Pipe Type) for 11 kV Ring Main Unit
fo|qr uxjh; forj.k [k.M&prqFkZ] xksj[kiqj ds {ks= esa fctusl Iyku esa Lohd`r ttZj ,0ch0 dsfcyksa dks [email protected] ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
LT AB Cable (3X150+1X120+1X16) sq mm
ST Pole 9 mtr Long
LT Cable 1X35 sq mm
Earthing complete
Supply of following material/fitting complete in all respect :-
LT Three Phase Distribution box
Clamp for LT Three Phase DB Box
Suspension Clamp with I hook (Insulated)
Dead end Clamp with I hook (Insulated)
Piercing Connector (Insulated)
GI Nuts & bolts of different sizes
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of PCC Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp/PCC/LT clamp, F-Bracket, LT shacle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). All work will be done as per RESPO norms & relevent IS Specification.
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Laying & sagging of ABC (3X150+1X120+1X16) Sq.mm. Cable of LT Line with fixing of Distribution Box with Clamp, Insulated Dead end clamp with I hook, Suspension clamp with I hook(Insulated), LT insulated Piercing connector, XLPE 1X35 Sq.mm. Al. cable for enerzing DB, XLPE 1X16 Sq.mm. Al. cable for giving connection to Street Light and nuts&bolts off size by the contractor.
Dismentling of old existing A.B. Cable
Dismentling of old existing ST Pole
Carriage of old existing conductor & Pole from work site to store centre
Disconnection & reconnection of consumer service cables
fo|qr uxjh; forj.k [k.M&prqFkZ] xksj[kiqj ds {ks= esa fctusl Iyku esa Lohd`r ttZj rkj cnyus ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
ACSR Dog Conductor
ST Pole 11 mtr long
11 KV Pin Insulator with pin
11 KV Disc insulaor with fiitings
11 KV V cross arm
11 KV T-Off Channel
Stay complete (Stay rod 16X1800 mm, stay wire 5 kg, stay clamp, bolt & nuts)
Earthing complete
Supply of following material/fitting complete in all respect :-
F Bracket
Holding Clamp
Nuts & bolts of different sizes
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of PCC Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp/PCC/LT clamp, F-Bracket, LT shacle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). All work will be done as per RESPO norms & relevent IS Specification.
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Laying of ACSR Dog/Weasel conductor for LT/HT Line with fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size as per required.
Dismentling of old existing Line
Dismentling of old existing ST Pole
Carriage of old existing conductor & Pole from work site to store centre
fo|qr uxjh; forj.k [k.M&prqFkZ] xksj[kiqj ds {ks= esa fctusl Iyku esa Lohd`r 11 ds0oh0 vksojgsM ykbu dks Hkwfexr djus ds dk;Z dks lseh VuZdh ds vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k %&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
3x185 mm2 XLPE 11 KV
Cable jointing kit 11 KV XLPE 3X185 sq mm
S.T. Pole 11 Mtr. Long
11 KV Dropper Channel
11 KV Top Channel
11 KV Pin Insulator
11 KV pin with net
Earthing Complete
Supply of following material/fitting complete in all respect :-
HDPE Pipe dia 150 mm PN 6 PE 8
Holding clamps for top, dropper, t-off etc
Nuts & Bolts off size
G.I Pipe dia 150 mm
The excavation of 2 No foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Laying and dressing of HDPE Pipe by Horizontal drilling method as per RESPO norms. The Depth of horizontal drilling shall be between 2 to 3 meters or as per site required.
Laying and dressing of under ground 11 KV 3X185 sq mm XLPE Cable by Horizontal drilling method as per RESPO norms. The Depth of horizontal drilling shall be between 2 to 3 meters or as per site required.
Erection of 11 KV 3X185 sq mm XLPE Cable Jointing Kit with complete work
Making Loop alongwith dressing, Marking, Tagging and Hoisting of cable on Single/Double pole using G.I. Pipe 6"dia 3 mtr. Long with complete work.
INDIA SUPPY CORPORATION
M/s Anil kumar singh
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .